Siemens Logo

RCBO 63 A 2-pole 4-module C characteristic type AC 30 mA, use of these devices is not permitted in all countries. Observe national installation regulations! - 5SU1324 -1RC63

(0 Reviews)
Best Price (Excl. GST):
15,025 / nos MRP: ₹15,025 / nos
GST (18%): 2,705
Total Price (Incl. GST): ₹17,730
Available as per OEM Lead Time
Quantity:
nos
Secure
Fast Delivery
24/7 Support

100% Genuine Product

Industrial Grade

Quality Tested

GST Invoice Available

Product Description

Siemens 5SU1324-1RC63 RCBO – 63A, 2-Pole, 30mA, Type AC, C-Characteristic

The Siemens 5SU1324-1RC63 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to provide integrated overload, short-circuit and residual-current protection in one compact device. The exact product data specifies a 63 A, 2-pole, 4-module, C-characteristic, Type AC, 30 mA RCBO for compatible single-phase electrical applications. Siemens technical data specifies 240 V AC, 50 Hz, 10 kA short-circuit breaking capacity according to EN 61009-1, and 15 kA according to IEC 60947-2.

The product description also carries an important Siemens warning: use of these devices is not permitted in all countries; national installation regulations must be observed.

Siemens 5SU1324-1RC63 RCBO

The 5SU1324-1RC63 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family.

An RCBO combines:

  • Overload protection

  • Short-circuit protection

  • Residual-current protection

in one device.

This integrated design can simplify circuit-level protection compared with separate MCB and RCCB arrangements.

The exact article is identified as 63 A, 2-pole, 4-module, C characteristic, Type AC, 30 mA.

63 A Rated Current

The 5SU1324-1RC63 has a rated current of 63 A.

It is intended for compatible higher-current single-phase circuits and feeders where a 63 A protective device is required.

Final selection should consider:

  • Connected load

  • Cable ampacity

  • Installation method

  • Ambient conditions

  • Prospective short-circuit current

  • Protection coordination

  • Applicable electrical regulations

The exact product data confirms the 63 A operational current.

C Tripping Characteristic

The RCBO uses a C tripping characteristic.

The C curve is intended for compatible circuits where moderate starting or inrush current may occur during normal operation.

Potential applications include:

  • Pumps

  • Fans

  • Small motors

  • Control transformers

  • Contactors

  • Solenoids

  • Industrial auxiliary equipment

  • Selected electrical equipment

The exact Siemens data confirms the C tripping characteristic.

Type AC Residual Current Protection

The 5SU1324-1RC63 uses Type AC residual-current protection.

Type AC protection is intended for compatible sinusoidal alternating residual currents.

The leakage-current waveform of connected equipment should be evaluated before selecting Type AC. Equipment capable of producing pulsating DC or other residual-current components may require another residual-current type.

The exact article is identified as Type AC.

30 mA Residual Current Sensitivity

The RCBO has a rated residual operating current of 30 mA.

When the residual-current condition reaches the specified operating threshold, the device disconnects the protected circuit.

The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable national requirements. The exact Siemens technical data confirms 30 mA residual-current sensitivity.

2-Pole Configuration

The device has 2 poles, with both poles protected, and is intended for compatible single-phase applications.

The two-pole arrangement allows the relevant phase and neutral circuit arrangement to be incorporated into the protection system.

Typical applications include:

  • Single-phase distribution boards

  • Commercial electrical panels

  • Building electrical systems

  • Equipment feeders

  • Office circuits

  • Industrial auxiliary supplies

  • Control-panel circuits

The exact Siemens data specifies 2 poles, 2 protected poles and 2P construction.

240 V AC Application

The exact technical data specifies a 240 V AC supply voltage and 50 Hz operating frequency.

Indian product information also identifies the device for the 240/415 V AC family and lists 50/60 Hz in product specifications.

For this two-pole article, the applicable single-phase system voltage should be checked against the installation design and current Siemens documentation.

10 kA Short-Circuit Breaking Capacity

The 5SU1324-1RC63 has a 10 kA short-circuit breaking capacity according to EN 61009-1.

The technical data additionally specifies:

  • 10 kA according to EN 60898

  • 15 kA according to IEC 60947-2

  • 10 kA rated residual switching capacity according to IEC 61009-1

  • Energy limitation class 3

The prospective short-circuit current at the installation point should still be verified during system design.

Combined Overcurrent and Residual-Current Protection

The main advantage of the 5SU1324-1RC63 is its integrated protection arrangement.

A conventional protection arrangement may use:

MCB + RCCB

An RCBO combines these functions:

RCBO = Overload + Short Circuit + Residual Current Protection

This can reduce component count and simplify individual circuit protection.

4-Module Design

The product is specified as a 4-module RCBO.

Siemens technical data specifies 4 modular width units and a physical width of 72 mm.

Indian product information also identifies the exact article as a 4-module, 2-pole device.

The 4-module designation refers to physical panel space and does not represent a power rating.

Physical Dimensions

The Siemens technical data specifies approximately:

  • Height: 90 mm

  • Width: 72 mm

  • Depth: 70 mm

  • Installation depth: 70 mm

  • Modular width units: 4

  • Net weight: approximately 502 g

  • Mounting position: Any

These dimensions are useful for panel builders when checking DIN-rail and enclosure space.

DIN-Rail / Modular Installation

The Siemens 5SU1 RCBO family is designed for modular electrical installation.

The 5SU1324-1RC63 can be integrated into suitable:

  • DIN-rail distribution boards

  • Commercial panels

  • Control panels

  • Sub-distribution boards

  • Industrial electrical enclosures

The installation should follow Siemens' wiring, mounting and terminal requirements.

Neutral Conductor Switching

The technical data specifies neutral conductor switching.

This supports suitable two-pole phase-and-neutral circuit arrangements.

Flexible Power-Supply Connection

The Siemens technical data specifies that the power supply can be connected from either the top or bottom.

This provides practical flexibility during panel wiring.

Overload Protection

The overcurrent section of the RCBO protects the circuit against sustained excessive current caused by overload.

The 63 A rating should be coordinated with:

  • Cable ampacity

  • Connected load

  • Installation method

  • Ambient temperature

  • Protection requirements

Short-Circuit Protection

The RCBO also provides integrated short-circuit protection.

The specified 10 kA breaking capacity should be evaluated against the prospective fault current at the installation point.

Residual-Current Protection

Residual current occurs when part of the electrical current flows through an unintended path, such as leakage to earth.

The RCBO monitors the residual-current condition and disconnects the protected circuit when the specified 30 mA threshold is reached.

This adds residual-current protection to the integrated overload and short-circuit functions.

C-Curve Applications

The C characteristic can be suitable for compatible loads with moderate inrush current.

Potential applications include:

  • Pumps

  • Fans

  • Small motors

  • Solenoids

  • Contactors

  • Control transformers

  • Industrial auxiliary equipment

  • Selected commercial equipment

The actual application should be evaluated according to the load's starting-current characteristics.

Type AC Applications

The 5SU1324-1RC63 is intended for compatible circuits with suitable sinusoidal AC residual currents.

For modern electronic equipment containing rectifiers, variable-speed drives or other power electronics, the appropriate residual-current type should be verified before selecting Type AC.

Single-Phase Electrical Applications

The 5SU1324-1RC63 can be considered for compatible:

  • Commercial distribution boards

  • Building electrical panels

  • Equipment feeders

  • Office circuits

  • Industrial auxiliary circuits

  • Control-panel supplies

  • Single-phase equipment

  • Dedicated electrical circuits

The final application should follow the electrical design and applicable regulations.

Protection Coordination

A typical arrangement can be:

Incoming Supply → RCBO → Protected Single-Phase Load

The complete protection design should consider:

  • Prospective short-circuit current

  • Cable capacity

  • Load current

  • C-curve characteristics

  • 30 mA residual-current sensitivity

  • Upstream protection

  • Applicable electrical standards

Maintenance and Testing

RCBOs should be included in the electrical installation's regular inspection and testing program.

The test function should be operated according to Siemens' instructions and applicable maintenance requirements to verify residual-current operation.

Regular testing helps confirm that the protective mechanism remains operational.

Installation Considerations

Before selecting the 5SU1324-1RC63, verify:

  • Rated current: 63 A

  • Residual-current sensitivity: 30 mA

  • Residual-current type: Type AC

  • Tripping characteristic: C

  • Pole configuration: 2-pole

  • Rated supply voltage: 240 V AC

  • Operating frequency: 50 Hz

  • Short-circuit breaking capacity: 10 kA

  • Panel space: 4 modules

  • Cable size and installation method

  • Load starting characteristics

  • Applicable national installation regulations

Important Country-Specific Installation Note

The exact Siemens product designation states:

“Use of these devices is not permitted in all countries. Observe national installation regulations!”

This warning should remain visible on the SB Smart product page.

For installations in India, applicable Indian electrical requirements and the latest Siemens installation documentation should be checked before installation.

Difference from Type A Version

The Siemens Industry Mall lists 5SU1324-7RC63 as a 63 A, 2-pole, 4-module, C-characteristic, Type A, 30 mA RCBO.

Therefore:

5SU1324-1RC63 → Type AC, 63 A, 30 mA

5SU1324-7RC63 → Type A, 63 A, 30 mA

The principal difference is the residual-current type.

Difference from 30 mA Type A Version

The 5SU1324-7RC63 has the same basic 63 A, 2-pole, 4-module, C-characteristic and 30 mA configuration but uses Type A residual-current detection.

This makes the residual-current type an important parameter when selecting an alternative.

Difference from Lower Current Versions

The Siemens 5SU1 two-pole range contains different rated-current variants.

For example, Siemens documentation lists 5SU1324 Type A C-characteristic variants at ratings including 6 A, 10 A, 13 A, 16 A, 20 A, 25 A and 32 A, depending on the exact configuration.

The 5SU1324-1RC63 is specifically the 63 A version, so its current rating must be matched with the protected circuit.

Difference from 4-Pole RCBO

The 5SU1344 family contains 4-pole RCBOs for compatible three-phase-plus-neutral applications.

The 5SU1324-1RC63 is a 2-pole device for compatible single-phase applications.

The pole configuration must therefore be checked before selecting a replacement.

Difference from Type A / D Characteristic

A D-characteristic Type A RCBO is intended for compatible loads with higher starting or inrush currents.

The 5SU1324-1RC63 specifically uses a C characteristic, so it should be selected where the C curve matches the load and protection-coordination requirements.

Difference from 100 mA or 300 mA Versions

The 5SU1324-1RC63 is specifically a 30 mA configuration.

A 100 mA or 300 mA RCBO has a different residual-current operating threshold and should not be treated as an exact replacement without confirming the protection design.

Difference Between RCBO and RCCB

The 5SU1324-1RC63 is an RCBO, not simply an RCCB.

An RCCB primarily provides residual-current protection and normally requires separate overcurrent protection.

An RCBO combines:

Residual-current protection + overload protection + short-circuit protection

in one device.

Suitable for Electrical Panel Builders and Industrial Buyers

The Siemens 5SU1324-1RC63 is relevant for:

  • Electrical panel builders

  • Industrial buyers

  • Electrical contractors

  • OEMs

  • Machine builders

  • Facility-maintenance teams

  • Commercial electrical contractors

  • Electrical distributors

  • Automation system integrators

  • Electrical product dealers

For SB Smart, the product is positioned as a Siemens SENTRON / Betagard 5SU1 Type AC RCBO for 63 A single-phase circuit protection with C characteristic and 30 mA sensitivity.

These values are taken from the technical data for the exact 5SU1324-1RC63 article.

Key Features

  • Siemens SENTRON / Betagard 5SU1 RCBO

  • Article number 5SU1324-1RC63

  • 63 A rated current

  • 2-pole configuration

  • 4-module format

  • Type AC residual-current protection

  • 30 mA residual-current sensitivity

  • C tripping characteristic

  • 240 V AC supply voltage

  • 50 Hz operating frequency

  • 10 kA EN 61009-1 short-circuit breaking capacity

  • 15 kA IEC 60947-2 switching capacity

  • 10 kA residual switching capacity

  • 440 V insulation voltage

  • 4 kV surge-voltage resistance

  • Neutral conductor switching

  • Touch protection

  • Top or bottom power-supply connection

  • Integrated overload and short-circuit protection

  • Integrated residual-current protection

  • Modular DIN-rail installation

Benefits

  • Combined protection: Integrates overload, short-circuit and residual-current protection in one device.

  • 63 A rating: Suitable for compatible higher-current single-phase circuits.

  • Type AC protection: Designed for compatible sinusoidal AC residual currents.

  • 30 mA sensitivity: Provides residual-current protection at the specified operating threshold.

  • C characteristic: Suitable for compatible loads with moderate inrush current.

  • 2-pole design: Suitable for compatible single-phase applications.

  • 4-module format: Provides a modular solution for higher-current two-pole circuit protection.

  • 10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.

  • Neutral switching: Supports phase-and-neutral circuit arrangements.

  • Flexible supply connection: Power can be connected from the top or bottom.

Why Choose Siemens 5SU1324-1RC63?

The Siemens 5SU1324-1RC63 combines 63 A overcurrent protection, C-curve tripping and Type AC 30 mA residual-current protection in a 2-pole, 4-module RCBO.

The exact Siemens technical data confirms 240 V AC, 50 Hz, 63 A, 2-pole configuration, Type AC, 30 mA sensitivity, C characteristic and 10 kA EN 61009-1 short-circuit breaking capacity.

For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 63 A, 30 mA single-phase circuit protection with C characteristic across India.

The country-use warning should remain clearly visible because Siemens states that these devices are not permitted in all countries and national installation regulations must be observed.

Delivery Across India

SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.

Frequently Asked Questions

1. What is Siemens 5SU1324-1RC63?

The 5SU1324-1RC63 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 63 A, with 2 poles, 4-module width, C characteristic, Type AC residual-current protection and 30 mA sensitivity.

2. Is this an RCBO or RCCB?

It is an RCBO, meaning it combines residual-current and overcurrent protection in one device.

3. What is the rated current?

The rated current is 63 A.

4. What is the residual-current sensitivity?

The rated residual operating current is 30 mA.

5. What type of residual-current protection does it use?

It uses Type AC residual-current protection.

6. What is the tripping characteristic?

It has a C tripping characteristic.

7. How many poles does it have?

It has 2 poles, with both poles protected.

8. What is the module width?

It is a 4-module / 4 MW device with a physical width of approximately 72 mm.

9. What is the rated voltage?

The exact technical data specifies 240 V AC at 50 Hz.

10. What is the short-circuit breaking capacity?

The product is specified with 10 kA according to EN 61009-1, with 15 kA according to IEC 60947-2 for the applicable switching-capacity parameter.

11. Is this product permitted in every country?

No. Siemens explicitly states that use of these devices is not permitted in all countries and that national installation regulations must be observed.

12. What is the difference between 5SU1324-1RC63 and 5SU1324-7RC63?

5SU1324-1RC63: 63 A, 2-pole, Type AC, 30 mA, C characteristic.

5SU1324-7RC63: 63 A, 2-pole, Type A, 30 mA, C characteristic.

The main difference is the residual-current type.

13. What is the difference between 5SU1324-1RC63 and a 4-pole 63 A RCBO?

The 5SU1324-1RC63 is a 2-pole RCBO for compatible single-phase applications, while the 5SU1344 series contains 4-pole variants for compatible three-phase-plus-neutral systems.

14. Where can I buy Siemens 5SU1324-1RC63 in India?

SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.

Technical Specifications

Parameter

Specification

Product Series

Siemens SENTRON Betagard 5SU1

Part Number

5SU1324-1RC63

Product Type

RCBO (Residual Current Breaker with Overload)

Poles

2P

Rated Current

63A

Tripping Curve

C Curve

Residual Current

30 mA

Residual Type

AC Type

Rated Voltage

230/240V AC

Breaking Capacity

10 kA

Mounting Type

DIN Rail

Function

Overload + Short circuit + Earth leakage protection

Customer Reviews

Write a Review

No reviews yet.

Why Buy From SB Smart?

Authorized Supplier
Genuine products directly from manufacturers with warranty support.
Industrial Expertise
Over 10 years of experience in industrial automation and electricals.
PAN India Delivery
Fast and secure shipping to all major industrial hubs across India.
Dedicated Support
Expert technical team available for product selection and support.

Request a Quote

×
Product: Product Name

Thank You!

Your quote request has been submitted successfully.

Our team will contact you shortly.

Product Enquiry

×
Enquiring for: Product Name

Enquiry Sent!

We have received your enquiry.

Our team will get back to you soon.