The Siemens 5SU1324-1RC63 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to provide integrated overload, short-circuit and residual-current protection in one compact device. The exact product data specifies a 63 A, 2-pole, 4-module, C-characteristic, Type AC, 30 mA RCBO for compatible single-phase electrical applications. Siemens technical data specifies 240 V AC, 50 Hz, 10 kA short-circuit breaking capacity according to EN 61009-1, and 15 kA according to IEC 60947-2.
The product description also carries an important Siemens warning: use of these devices is not permitted in all countries; national installation regulations must be observed.
The 5SU1324-1RC63 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family.
An RCBO combines:
Overload protection
Short-circuit protection
Residual-current protection
in one device.
This integrated design can simplify circuit-level protection compared with separate MCB and RCCB arrangements.
The exact article is identified as 63 A, 2-pole, 4-module, C characteristic, Type AC, 30 mA.
The 5SU1324-1RC63 has a rated current of 63 A.
It is intended for compatible higher-current single-phase circuits and feeders where a 63 A protective device is required.
Final selection should consider:
Connected load
Cable ampacity
Installation method
Ambient conditions
Prospective short-circuit current
Protection coordination
Applicable electrical regulations
The exact product data confirms the 63 A operational current.
The RCBO uses a C tripping characteristic.
The C curve is intended for compatible circuits where moderate starting or inrush current may occur during normal operation.
Potential applications include:
Pumps
Fans
Small motors
Control transformers
Contactors
Solenoids
Industrial auxiliary equipment
Selected electrical equipment
The exact Siemens data confirms the C tripping characteristic.
The 5SU1324-1RC63 uses Type AC residual-current protection.
Type AC protection is intended for compatible sinusoidal alternating residual currents.
The leakage-current waveform of connected equipment should be evaluated before selecting Type AC. Equipment capable of producing pulsating DC or other residual-current components may require another residual-current type.
The exact article is identified as Type AC.
The RCBO has a rated residual operating current of 30 mA.
When the residual-current condition reaches the specified operating threshold, the device disconnects the protected circuit.
The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable national requirements. The exact Siemens technical data confirms 30 mA residual-current sensitivity.
The device has 2 poles, with both poles protected, and is intended for compatible single-phase applications.
The two-pole arrangement allows the relevant phase and neutral circuit arrangement to be incorporated into the protection system.
Typical applications include:
Single-phase distribution boards
Commercial electrical panels
Building electrical systems
Equipment feeders
Office circuits
Industrial auxiliary supplies
Control-panel circuits
The exact Siemens data specifies 2 poles, 2 protected poles and 2P construction.
The exact technical data specifies a 240 V AC supply voltage and 50 Hz operating frequency.
Indian product information also identifies the device for the 240/415 V AC family and lists 50/60 Hz in product specifications.
For this two-pole article, the applicable single-phase system voltage should be checked against the installation design and current Siemens documentation.
The 5SU1324-1RC63 has a 10 kA short-circuit breaking capacity according to EN 61009-1.
The technical data additionally specifies:
10 kA according to EN 60898
15 kA according to IEC 60947-2
10 kA rated residual switching capacity according to IEC 61009-1
Energy limitation class 3
The prospective short-circuit current at the installation point should still be verified during system design.
The main advantage of the 5SU1324-1RC63 is its integrated protection arrangement.
A conventional protection arrangement may use:
MCB + RCCB
An RCBO combines these functions:
RCBO = Overload + Short Circuit + Residual Current Protection
This can reduce component count and simplify individual circuit protection.
The product is specified as a 4-module RCBO.
Siemens technical data specifies 4 modular width units and a physical width of 72 mm.
Indian product information also identifies the exact article as a 4-module, 2-pole device.
The 4-module designation refers to physical panel space and does not represent a power rating.
The Siemens technical data specifies approximately:
Height: 90 mm
Width: 72 mm
Depth: 70 mm
Installation depth: 70 mm
Modular width units: 4
Net weight: approximately 502 g
Mounting position: Any
These dimensions are useful for panel builders when checking DIN-rail and enclosure space.
The Siemens 5SU1 RCBO family is designed for modular electrical installation.
The 5SU1324-1RC63 can be integrated into suitable:
DIN-rail distribution boards
Commercial panels
Control panels
Sub-distribution boards
Industrial electrical enclosures
The installation should follow Siemens' wiring, mounting and terminal requirements.
The technical data specifies neutral conductor switching.
This supports suitable two-pole phase-and-neutral circuit arrangements.
The Siemens technical data specifies that the power supply can be connected from either the top or bottom.
This provides practical flexibility during panel wiring.
The overcurrent section of the RCBO protects the circuit against sustained excessive current caused by overload.
The 63 A rating should be coordinated with:
Cable ampacity
Connected load
Installation method
Ambient temperature
Protection requirements
The RCBO also provides integrated short-circuit protection.
The specified 10 kA breaking capacity should be evaluated against the prospective fault current at the installation point.
Residual current occurs when part of the electrical current flows through an unintended path, such as leakage to earth.
The RCBO monitors the residual-current condition and disconnects the protected circuit when the specified 30 mA threshold is reached.
This adds residual-current protection to the integrated overload and short-circuit functions.
The C characteristic can be suitable for compatible loads with moderate inrush current.
Potential applications include:
Pumps
Fans
Small motors
Solenoids
Contactors
Control transformers
Industrial auxiliary equipment
Selected commercial equipment
The actual application should be evaluated according to the load's starting-current characteristics.
The 5SU1324-1RC63 is intended for compatible circuits with suitable sinusoidal AC residual currents.
For modern electronic equipment containing rectifiers, variable-speed drives or other power electronics, the appropriate residual-current type should be verified before selecting Type AC.
The 5SU1324-1RC63 can be considered for compatible:
Commercial distribution boards
Building electrical panels
Equipment feeders
Office circuits
Industrial auxiliary circuits
Control-panel supplies
Single-phase equipment
Dedicated electrical circuits
The final application should follow the electrical design and applicable regulations.
A typical arrangement can be:
Incoming Supply → RCBO → Protected Single-Phase Load
The complete protection design should consider:
Prospective short-circuit current
Cable capacity
Load current
C-curve characteristics
30 mA residual-current sensitivity
Upstream protection
Applicable electrical standards
RCBOs should be included in the electrical installation's regular inspection and testing program.
The test function should be operated according to Siemens' instructions and applicable maintenance requirements to verify residual-current operation.
Regular testing helps confirm that the protective mechanism remains operational.
Before selecting the 5SU1324-1RC63, verify:
Rated current: 63 A
Residual-current sensitivity: 30 mA
Residual-current type: Type AC
Tripping characteristic: C
Pole configuration: 2-pole
Rated supply voltage: 240 V AC
Operating frequency: 50 Hz
Short-circuit breaking capacity: 10 kA
Panel space: 4 modules
Cable size and installation method
Load starting characteristics
Applicable national installation regulations
The exact Siemens product designation states:
“Use of these devices is not permitted in all countries. Observe national installation regulations!”
This warning should remain visible on the SB Smart product page.
For installations in India, applicable Indian electrical requirements and the latest Siemens installation documentation should be checked before installation.
The Siemens Industry Mall lists 5SU1324-7RC63 as a 63 A, 2-pole, 4-module, C-characteristic, Type A, 30 mA RCBO.
Therefore:
5SU1324-1RC63 → Type AC, 63 A, 30 mA
5SU1324-7RC63 → Type A, 63 A, 30 mA
The principal difference is the residual-current type.
The 5SU1324-7RC63 has the same basic 63 A, 2-pole, 4-module, C-characteristic and 30 mA configuration but uses Type A residual-current detection.
This makes the residual-current type an important parameter when selecting an alternative.
The Siemens 5SU1 two-pole range contains different rated-current variants.
For example, Siemens documentation lists 5SU1324 Type A C-characteristic variants at ratings including 6 A, 10 A, 13 A, 16 A, 20 A, 25 A and 32 A, depending on the exact configuration.
The 5SU1324-1RC63 is specifically the 63 A version, so its current rating must be matched with the protected circuit.
The 5SU1344 family contains 4-pole RCBOs for compatible three-phase-plus-neutral applications.
The 5SU1324-1RC63 is a 2-pole device for compatible single-phase applications.
The pole configuration must therefore be checked before selecting a replacement.
A D-characteristic Type A RCBO is intended for compatible loads with higher starting or inrush currents.
The 5SU1324-1RC63 specifically uses a C characteristic, so it should be selected where the C curve matches the load and protection-coordination requirements.
The 5SU1324-1RC63 is specifically a 30 mA configuration.
A 100 mA or 300 mA RCBO has a different residual-current operating threshold and should not be treated as an exact replacement without confirming the protection design.
The 5SU1324-1RC63 is an RCBO, not simply an RCCB.
An RCCB primarily provides residual-current protection and normally requires separate overcurrent protection.
An RCBO combines:
Residual-current protection + overload protection + short-circuit protection
in one device.
The Siemens 5SU1324-1RC63 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Facility-maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens SENTRON / Betagard 5SU1 Type AC RCBO for 63 A single-phase circuit protection with C characteristic and 30 mA sensitivity.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1324-1RC63
63 A rated current
2-pole configuration
4-module format
Type AC residual-current protection
30 mA residual-current sensitivity
C tripping characteristic
240 V AC supply voltage
50 Hz operating frequency
10 kA EN 61009-1 short-circuit breaking capacity
15 kA IEC 60947-2 switching capacity
10 kA residual switching capacity
440 V insulation voltage
4 kV surge-voltage resistance
Neutral conductor switching
Touch protection
Top or bottom power-supply connection
Integrated overload and short-circuit protection
Integrated residual-current protection
Modular DIN-rail installation
Combined protection: Integrates overload, short-circuit and residual-current protection in one device.
63 A rating: Suitable for compatible higher-current single-phase circuits.
Type AC protection: Designed for compatible sinusoidal AC residual currents.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
C characteristic: Suitable for compatible loads with moderate inrush current.
2-pole design: Suitable for compatible single-phase applications.
4-module format: Provides a modular solution for higher-current two-pole circuit protection.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
Neutral switching: Supports phase-and-neutral circuit arrangements.
Flexible supply connection: Power can be connected from the top or bottom.
The Siemens 5SU1324-1RC63 combines 63 A overcurrent protection, C-curve tripping and Type AC 30 mA residual-current protection in a 2-pole, 4-module RCBO.
The exact Siemens technical data confirms 240 V AC, 50 Hz, 63 A, 2-pole configuration, Type AC, 30 mA sensitivity, C characteristic and 10 kA EN 61009-1 short-circuit breaking capacity.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 63 A, 30 mA single-phase circuit protection with C characteristic across India.
The country-use warning should remain clearly visible because Siemens states that these devices are not permitted in all countries and national installation regulations must be observed.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
The 5SU1324-1RC63 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 63 A, with 2 poles, 4-module width, C characteristic, Type AC residual-current protection and 30 mA sensitivity.
It is an RCBO, meaning it combines residual-current and overcurrent protection in one device.
The rated current is 63 A.
The rated residual operating current is 30 mA.
It uses Type AC residual-current protection.
It has a C tripping characteristic.
It has 2 poles, with both poles protected.
It is a 4-module / 4 MW device with a physical width of approximately 72 mm.
The exact technical data specifies 240 V AC at 50 Hz.
The product is specified with 10 kA according to EN 61009-1, with 15 kA according to IEC 60947-2 for the applicable switching-capacity parameter.
No. Siemens explicitly states that use of these devices is not permitted in all countries and that national installation regulations must be observed.
5SU1324-1RC63: 63 A, 2-pole, Type AC, 30 mA, C characteristic.
5SU1324-7RC63: 63 A, 2-pole, Type A, 30 mA, C characteristic.
The main difference is the residual-current type.
The 5SU1324-1RC63 is a 2-pole RCBO for compatible single-phase applications, while the 5SU1344 series contains 4-pole variants for compatible three-phase-plus-neutral systems.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens SENTRON Betagard 5SU1 |
|
Part Number |
5SU1324-1RC63 |
|
Product Type |
RCBO (Residual Current Breaker with Overload) |
|
Poles |
2P |
|
Rated Current |
63A |
|
Tripping Curve |
C Curve |
|
Residual Current |
30 mA |
|
Residual Type |
AC Type |
|
Rated Voltage |
230/240V AC |
|
Breaking Capacity |
10 kA |
|
Mounting Type |
DIN Rail |
|
Function |
Overload + Short circuit + Earth leakage protection |