The Siemens 5SU1344-7RC40 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in a single device. The exact product designation specifies 40 A, 4-pole, 7 modules, C characteristic, Type A and 30 mA residual-current sensitivity. Indian product listings confirm the same configuration and a 415 V AC rated voltage, while Siemens technical data for this product family specifies a 10 kA short-circuit breaking capacity.
The 5SU1344-7RC40 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. An RCBO combines overcurrent protection and residual-current protection in one integrated device.
It provides protection against:
Overload
Short circuit
Residual or earth-leakage current
This integrated construction can simplify circuit-level protection compared with using separate MCB and RCCB devices.
The exact product listing confirms 40 A, 4-pole, 7 modules, C characteristic, Type A and 30 mA.
The RCBO has a rated current of 40 A.
This makes it suitable for compatible three-phase circuits and feeders designed around a 40 A protective device.
The actual selection should consider:
Connected load
Cable ampacity
Installation method
Ambient conditions
Prospective short-circuit current
Protection coordination requirements
The 5SU1344-7RC40 uses a C tripping characteristic.
The C curve is intended for compatible circuits where normal operation may involve moderate starting or inrush current.
Potential applications include:
Pumps
Fans
Motors
Control transformers
Contactors
Solenoids
Industrial auxiliary equipment
Selected machinery
The actual tripping characteristic should be selected according to the load's starting-current characteristics and protection-coordination requirements. The exact product listing confirms the C curve.
The device uses Type A residual-current protection.
Type A protection is designed to detect suitable AC residual currents as well as pulsating DC residual-current components. This makes it suitable for many modern electrical and electronic loads.
Potential applications include:
Electronic power supplies
Automation equipment
Rectifier-based equipment
Industrial control systems
Modern machinery
Commercial electronic equipment
The exact product is identified as Type A.
The 5SU1344-7RC40 has a rated residual operating current of 30 mA.
When the residual-current condition reaches the specified operating threshold, the RCBO disconnects the protected circuit.
The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable installation requirements.
The exact product listing confirms 30 mA residual-current sensitivity.
The RCBO has 4 poles, making it suitable for compatible three-phase-plus-neutral electrical systems.
The four-pole arrangement allows the three phases and neutral to be incorporated into the circuit protection arrangement.
Typical applications include:
Three-phase distribution boards
Industrial feeder circuits
PCC panels
MCC panels
Commercial electrical panels
Machine power circuits
Factory electrical systems
Sub-distribution boards
The exact product is listed as 4-pole / 4P.
Indian product information identifies the exact 5SU1344-7RC40 as a 415 V AC device.
This makes it suitable for compatible three-phase low-voltage distribution systems where the system voltage and protection requirements match the device.
The actual installation should always be checked against the applicable Siemens technical documentation and electrical-system design.
The exact product listing specifies a 10 kA breaking capacity.
The prospective short-circuit current at the installation point should still be evaluated during system design, together with upstream protection and coordination requirements.
Because the device is an RCBO, its overcurrent function also provides short-circuit protection within its specified ratings.
The main advantage of the 5SU1344-7RC40 is its integrated protection arrangement.
A conventional installation may use:
MCB + RCCB
An RCBO combines these functions:
RCBO = Overload + Short Circuit + Residual Current Protection
This can simplify circuit-level protection and reduce the number of separate protection components.
The product designation specifies 7 modules.
The Siemens 5SU1 4-pole construction uses approximately 126 mm physical width for this configuration, corresponding to 7 modular-width units in the technical documentation for the family. The 7-module designation refers to physical panel space and does not indicate a power rating.
The technical information for the corresponding 4-pole 7-module 5SU1 construction specifies approximately:
Height: 90 mm
Width: 126 mm
Depth: 70 mm
Installation depth: 70 mm
Modular width: 7 units
These dimensions are useful for panel builders when checking enclosure and DIN-rail space.
The Siemens 5SU1 RCBO family is designed for modular electrical installation.
The 5SU1344-7RC40 can be integrated into suitable:
Distribution boards
Industrial control panels
PCC panels
MCC panels
Machine panels
Commercial switchboards
Factory electrical enclosures
Panel builders should verify available space and compatible accessories before installation.
The corresponding Siemens technical construction specifies neutral conductor switching for the 4-pole RCBO arrangement.
This supports use in compatible three-phase-plus-neutral systems.
The Siemens technical data for the corresponding 4-pole 7-module construction specifies that the power supply can be connected from either the top or bottom.
This provides flexibility during electrical-panel wiring.
The RCBO's overcurrent section protects the connected circuit against sustained excessive current caused by overload.
The 40 A rating should be coordinated with:
Cable ampacity
Connected load
Installation method
Ambient temperature
Protection-coordination requirements
The RCBO also provides integrated short-circuit protection.
Its 10 kA breaking capacity should be evaluated against the prospective fault current at the installation point.
Residual current occurs when part of the electrical current flows through an unintended path, such as leakage toward earth.
The RCBO monitors the residual-current condition and disconnects the protected circuit when the specified 30 mA threshold is reached.
This adds residual-current protection to the integrated overload and short-circuit functions.
The C characteristic can be suitable for compatible loads with moderate starting or inrush current.
Potential applications include:
Pumps
Fans
Motors
Contactors
Solenoids
Control transformers
Industrial machinery
Automation equipment
The actual application should be evaluated according to the load's starting characteristics and protection coordination.
Type A protection is useful for compatible installations where residual currents may include pulsating DC components.
Potential applications include:
Automation systems
Electronic control panels
Switching power supplies
Rectifier-based equipment
Industrial instrumentation
Modern electrical machinery
The connected equipment's leakage-current waveform should be checked before final selection.
The 5SU1344-7RC40 can be considered for compatible:
Industrial distribution boards
Three-phase equipment feeders
PCC panels
MCC panels
Machine power circuits
Commercial switchboards
Factory electrical systems
Sub-distribution boards
Building electrical panels
A typical arrangement can be:
Incoming Supply → RCBO → Protected Three-Phase Load
The complete protection design should consider:
Prospective short-circuit current
Cable capacity
Load current
C-curve characteristics
30 mA residual-current sensitivity
Upstream protection
Applicable electrical standards
RCBOs should be included in the electrical installation's regular inspection and testing program.
The test function should be operated according to Siemens' instructions and applicable maintenance requirements to verify the residual-current protection function.
Regular testing helps confirm that the protection mechanism remains operational.
Before selecting the 5SU1344-7RC40, verify:
Rated current: 40 A
Residual-current sensitivity: 30 mA
Residual-current type: Type A
Tripping characteristic: C
Pole configuration: 4-pole
Rated voltage: 415 V AC
Short-circuit capacity: 10 kA
Required panel space: 7 modules
Cable size and installation method
Load starting characteristics
Applicable national electrical regulations
The 5SU1344-8RC40 is the corresponding 40 A, 4-pole, 7-module, Type A, 30 mA configuration with a D characteristic.
Therefore:
5SU1344-7RC40 → C characteristic
5SU1344-8RC40 → D characteristic
The main difference is the overcurrent tripping characteristic. The D curve is intended for compatible loads with higher starting or inrush currents.
The 5SU1344-1RC40 is a 40 A, 4-pole, 8-module, C-characteristic, Type AC, 30 mA RCBO.
Therefore:
5SU1344-7RC40 → Type A, 40 A, 30 mA, 7 modules
5SU1344-1RC40 → Type AC, 40 A, 30 mA, 8 modules
The residual-current type and module configuration are different.
The 5SU1444-7RC40 is the corresponding Type A, C-characteristic configuration with 100 mA residual-current sensitivity.
Therefore:
5SU1344-7RC40 → Type A, 40 A, 30 mA
5SU1444-7RC40 → Type A, 40 A, 100 mA
The main difference is residual-current sensitivity.
A 300 mA Type A RCBO in the 5SU1 family has a different residual-current sensitivity from this model.
The 5SU1344-7RC40 is specifically the 30 mA configuration, so a 300 mA model should not be treated as a direct replacement without checking the protection requirement.
The 5SU1344-7RC63 is the corresponding 63 A, 4-pole, 7-module, Type A, 30 mA, C-characteristic model.
Therefore:
5SU1344-7RC40 → 40 A
5SU1344-7RC63 → 63 A
The principal difference is the rated current.
The 5SU1344-7RC32 is the lower-rated variant in the same general Type A, C-characteristic, 30 mA family.
The 5SU1344-7RC40 should be selected when the protected circuit requires a 40 A rated protective device.
The 5SU1354 family contains 2-pole RCBOs for compatible single-phase applications.
The 5SU1344-7RC40 is a 4-pole RCBO intended for compatible three-phase-plus-neutral systems, so pole configuration must be checked carefully before selecting an alternative.
The 5SU1344-7RC40 is an RCBO.
An RCCB primarily provides residual-current protection and normally requires separate overcurrent protection.
An RCBO combines:
Residual-current protection + overload protection + short-circuit protection
in one device.
The Siemens 5SU1344-7RC40 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Factory maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens SENTRON / Betagard 5SU1 Type A RCBO for 40 A three-phase circuit protection with C characteristic and 30 mA sensitivity.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON / Betagard 5SU1 |
| Article Number | 5SU1344-7RC40 |
| Product Type | Residual Current Circuit Breaker with Overcurrent Protection (RCBO) |
| Rated Current | 40 A |
| Number of Poles | 4 Pole / 4P |
| Number of Protected Poles | 4 |
| Tripping Characteristic | C Curve |
| Residual Current Type | Type A |
| Rated Residual Operating Current | 30 mA |
| Rated Operating Voltage | 415 V AC |
| Operating Frequency | 50 Hz |
| Insulation Voltage (Ui) | 440 V |
| Surge Voltage Resistance | 4 kV |
| Short-Circuit Breaking Capacity | 10 kA according to EN 61009-1 |
| EN 60898 Switching Capacity | 10 kA |
| IEC 60947-2 Switching Capacity | 15 kA |
| Rated Residual Switching Capacity | 10 kA |
| Energy Limitation Class | 3 |
| Overvoltage Category | III |
| Pollution Degree | 2 |
| Protection Degree | IP20 when installed in a suitable distribution board |
| Neutral Conductor Switching | Yes |
| Touch Protection | Yes |
| Power Supply Position | Top or bottom |
| Height | 90 mm |
| Width | 126 mm |
| Depth | 70 mm |
| Installation Depth | 70 mm |
| Modular Width Units | 7 |
| Mounting Position | Any |
| Operating Ambient Temperature | -25 °C to +45 °C |
The product listing confirms 40 A, 4-pole, 7 modules, C characteristic, Type A and 30 mA, while the corresponding Siemens 5SU1 technical construction confirms the 7-module dimensions and 10 kA protection class.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1344-7RC40
40 A rated current
4-pole configuration
7-module format
Type A residual-current protection
30 mA residual-current sensitivity
C tripping characteristic
415 V AC rated voltage
50 Hz operating frequency
10 kA short-circuit breaking capacity
15 kA IEC 60947-2 switching capacity
10 kA rated residual switching capacity
440 V insulation voltage
4 kV surge-voltage resistance
Neutral conductor switching
Top or bottom power-supply connection
Integrated overload and short-circuit protection
Integrated residual-current protection
Suitable for compatible three-phase-plus-neutral circuits
Combined protection: Integrates overload, short-circuit and residual-current protection in one device.
40 A rating: Suitable for compatible three-phase circuits and feeders.
Type A protection: Suitable where residual currents may include pulsating DC components.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
C characteristic: Suitable for compatible loads with moderate inrush current.
4-pole construction: Suitable for compatible three-phase-plus-neutral systems.
7-module format: Provides a modular four-pole protection solution.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
Neutral switching: Supports the four-pole circuit arrangement.
Flexible supply connection: Power can be connected from the top or bottom.
The Siemens 5SU1344-7RC40 combines 40 A overcurrent protection, C-curve tripping and Type A 30 mA residual-current protection in a 4-pole, 7-module RCBO.
The exact product listing confirms 40 A, 4-pole, 7 modules, C characteristic, Type A and 30 mA, with 10 kA breaking capacity.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type A RCBO for 40 A, 30 mA three-phase circuit protection with C characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1344-7RC40 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 40 A, with 4 poles, 7 modules, C characteristic, Type A residual-current protection and 30 mA sensitivity.
It is an RCBO, meaning it combines residual-current and overcurrent protection.
The rated current is 40 A.
The rated residual operating current is 30 mA.
It uses Type A residual-current protection.
It has a C tripping characteristic.
It has 4 poles, suitable for compatible three-phase-plus-neutral applications.
The product is specified as 7 modules, with approximately 126 mm physical width in the corresponding Siemens 5SU1 construction.
Indian product information identifies the exact article as 415 V AC.
The product is specified with a 10 kA breaking capacity.
5SU1344-7RC40: 40 A, 4-pole, Type A, 30 mA, C characteristic.
5SU1344-8RC40: 40 A, 4-pole, Type A, 30 mA, D characteristic.
The main difference is the overcurrent tripping characteristic.
5SU1344-7RC40: Type A, 40 A, 30 mA, C characteristic, 7 modules.
5SU1344-1RC40: Type AC, 40 A, 30 mA, C characteristic, 8 modules.
The main differences are the residual-current type and module configuration.
5SU1344-7RC40: 40 A, Type A, 30 mA, C characteristic.
5SU1344-7RC63: 63 A, Type A, 30 mA, C characteristic.
The main difference is the rated current.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens Betagard 5SU1 |
|
Part Number |
5SU1344-7RC40 |
|
Product Type |
RCBO (Residual Current Breaker with Overcurrent
Protection) |
|
Residual Current Type |
Type AC |
|
Rated Current |
40 A |
|
Tripping Characteristic |
C Curve |
|
Rated Residual Current |
30 mA |
|
Poles |
4 Pole |
|
Rated Voltage |
400–415 V AC |
|
Frequency |
50/60 Hz |
|
Breaking Capacity |
10 kA |
|
Mounting Type |
DIN Rail |
|
Protection |
Overload, Short Circuit & Earth Leakage |
|
Standard |
IEC 61009-1 / IEC 60947-2 |
|
Application |
Residential, Commercial & Industrial Panels |
No reviews yet.