The Siemens 5SU1344-8RC63 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to provide integrated overload, short-circuit and residual-current protection in one device. The exact Siemens datasheet identifies it as a 63 A, 4-pole, 7-module, D-characteristic, Type A, 30 mA RCBO for compatible three-phase-plus-neutral electrical systems. It is specified for 415 V AC, 50 Hz, with 10 kA short-circuit breaking capacity according to EN 61009-1.
The 5SU1344-8RC63 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. An RCBO combines the functions of overcurrent protection and residual-current protection in a single device.
It provides:
Overload protection
Short-circuit protection
Residual-current protection
This integrated design can simplify circuit-level protection compared with separate MCB and RCCB arrangements.
The exact product designation confirms 63 A, 4-pole, 7 modules, D characteristic, Type A and 30 mA.
The RCBO has a rated current of 63 A.
This makes it suitable for compatible higher-current three-phase circuits and feeders designed around a 63 A protective device.
The actual selection should take into account cable ampacity, connected load, installation method, ambient conditions and applicable electrical regulations.
The 5SU1344-8RC63 uses a D tripping characteristic.
The D curve is intended for compatible circuits that can experience relatively high starting or inrush currents during normal operation.
Potential applications include:
Motors
Transformers
Compressors
Industrial machinery
High-inrush equipment
Certain solenoid and electromagnetic loads
The D characteristic should be selected only where the load starting-current characteristics and protection coordination justify it.
The device uses Type A residual-current protection.
Type A protection is designed to detect suitable AC residual currents as well as pulsating DC residual-current components.
This makes it suitable for many modern electrical installations containing electronic and rectifier-based loads.
Potential applications include:
Electronic power supplies
Automation equipment
Rectifier circuits
Industrial control systems
Modern electrical machinery
Commercial electronic equipment
The exact Siemens datasheet identifies the residual-current type as Type A.
The 5SU1344-8RC63 has a rated residual operating current of 30 mA.
When the residual-current condition reaches the specified operating threshold, the RCBO disconnects the protected circuit.
The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable installation requirements.
The exact technical data confirms 30 mA residual-current sensitivity.
The RCBO has 4 poles, making it suitable for compatible three-phase plus neutral electrical systems.
The four-pole construction allows the three phases and neutral to be incorporated into the protection arrangement.
Typical applications include:
Three-phase distribution boards
Industrial feeder circuits
PCC panels
MCC panels
Commercial three-phase electrical panels
Machine power circuits
Factory electrical systems
Sub-distribution boards
The exact Siemens technical datasheet specifies 415 V AC supply voltage and 50 Hz operating frequency.
This makes the device suitable for compatible three-phase low-voltage distribution systems where the system voltage and protection requirements match the RCBO.
The 5SU1344-8RC63 has a 10 kA short-circuit breaking capacity according to EN 61009-1.
The Siemens technical data additionally specifies:
10 kA according to EN 60898
15 kA according to IEC 60947-2
10 kA rated residual switching capacity according to IEC 61009-1
Energy limitation class 3
The prospective short-circuit current at the installation point should still be verified during system design.
The main advantage of the 5SU1344-8RC63 is its integrated protection architecture.
A conventional arrangement may use:
MCB + RCCB
An RCBO combines the relevant functions:
RCBO = Overload + Short Circuit + Residual Current Protection
This can simplify circuit-level protection and reduce the number of separate protective devices.
The exact Siemens product designation specifies 7 modules.
The technical datasheet specifies 7 modular width units, with a physical width of 126 mm.
The 7-module designation refers to the physical panel width and does not represent a power rating.
The Siemens technical data specifies approximately:
Height: 90 mm
Width: 126 mm
Depth: 70 mm
Installation depth: 70 mm
Modular width units: 7
These dimensions are useful for panel builders when checking enclosure space.
The Siemens 5SU1 RCBO family is intended for modular electrical installation.
The 5SU1344-8RC63 can be integrated into suitable:
Distribution boards
Industrial control panels
PCC panels
MCC panels
Machine panels
Commercial switchboards
Factory electrical enclosures
The available panel space and mounting arrangement should be checked before installation.
The Siemens technical data specifies neutral conductor switching for the device.
This supports the four-pole arrangement used for compatible three-phase-plus-neutral circuits.
The technical datasheet specifies that the power supply can be connected from either the top or bottom.
This provides flexibility during panel wiring and installation.
The overcurrent section of the RCBO protects the connected circuit against sustained excessive current caused by overload.
The 63 A rated current should be coordinated with:
Cable ampacity
Connected load
Installation method
Ambient temperature
Protection coordination requirements
The RCBO also provides integrated short-circuit protection.
Its 10 kA EN 61009-1 breaking capacity should be considered against the prospective fault current at the installation point.
Residual current occurs when part of the electrical current flows through an unintended path, such as leakage toward earth.
The RCBO monitors the residual-current condition and disconnects the protected circuit when the specified 30 mA threshold is reached.
This adds residual-current protection to the integrated overload and short-circuit functions.
The D characteristic can be useful for compatible loads with high starting or inrush current.
Potential applications include:
Motor feeders
Transformer circuits
Compressors
Industrial machinery
High-inrush equipment
Selected automation applications
The D curve should not be selected merely because the application is industrial; the actual load starting current and protection coordination must be checked.
The Type A characteristic makes this RCBO suitable for compatible equipment where residual currents may contain pulsating DC components.
Potential applications include:
Automation systems
Electronic control panels
Switching power supplies
Rectifier-based equipment
Industrial instrumentation
Modern machinery
The connected equipment's leakage-current waveform should be checked before final selection.
The 5SU1344-8RC63 can be considered for compatible:
Industrial distribution boards
Three-phase equipment feeders
PCC panels
MCC panels
Machine power circuits
Commercial switchboards
Factory electrical systems
Sub-distribution boards
Building electrical panels
A typical arrangement can be:
Incoming Supply → RCBO → Protected Three-Phase Load
The complete protection design should consider:
Prospective short-circuit current
Cable capacity
Load current
D-curve characteristics
30 mA residual-current sensitivity
Upstream protection
Applicable electrical standards
RCBOs should be included in the electrical installation's regular inspection and testing program.
The test function should be operated according to Siemens' instructions and applicable maintenance requirements to verify the residual-current protection function.
Regular testing helps confirm that the protective mechanism remains operational.
Before selecting the 5SU1344-8RC63, verify:
Rated current: 63 A
Residual-current sensitivity: 30 mA
Residual-current type: Type A
Tripping characteristic: D
Pole configuration: 4-pole
Rated voltage: 415 V AC
Operating frequency: 50 Hz
Short-circuit breaking capacity: 10 kA
Panel space: 7 modules
Cable size and installation method
Load inrush characteristics
Applicable national electrical regulations
The 5SU1344-7RC63 is a corresponding Type A, C-characteristic 30 mA configuration in the Siemens 5SU1 range.
Therefore:
5SU1344-8RC63 → D characteristic
The main distinction from the corresponding C-curve variant is the overcurrent tripping characteristic.
The D curve is intended for higher inrush-current applications, while the C curve is intended for moderate inrush-current applications.
The 5SU1644-2RC63 is a Type AC D-characteristic RCBO with a different residual-current sensitivity configuration.
The 5SU1344-8RC63 is specifically:
63 A + 4-pole + 7 modules + D characteristic + Type A + 30 mA
The residual-current type and sensitivity should both be checked before selecting an alternative.
A 5SU1 Type A, D-characteristic, 300 mA RCBO has a different residual-current sensitivity from the 5SU1344-8RC63.
Therefore:
5SU1344-8RC63 → Type A, 30 mA
A 300 mA model should not be treated as a direct replacement without confirming the protection requirement.
A Type AC 30 mA model may have the same current rating and pole count but a different residual-current detection characteristic.
Therefore:
5SU1344-8RC63 → Type A, 30 mA
A Type AC equivalent should only be selected when the connected load and protection requirements support Type AC detection.
For the same 63 A, Type A, 30 mA, four-pole configuration:
D characteristic → 5SU1344-8RC63
The corresponding C-curve article should be selected where only moderate inrush capability is required.
The 5SU1624 and 5SU1354 families contain two-pole RCBO variants.
The 5SU1344-8RC63 is a 4-pole device intended for compatible three-phase-plus-neutral circuits.
Therefore, the pole configuration must be verified before replacing or ordering the product.
The Siemens 5SU1344-8RC63 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Factory maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens SENTRON / Betagard 5SU1 Type A RCBO for 63 A three-phase circuit protection with D characteristic and 30 mA sensitivity.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1344-8RC63
63 A rated current
4-pole configuration
7-module format
Type A residual-current protection
30 mA residual-current sensitivity
D tripping characteristic
415 V AC rated voltage
50 Hz operating frequency
10 kA EN 61009-1 short-circuit breaking capacity
15 kA IEC 60947-2 switching capacity
10 kA residual switching capacity
440 V insulation voltage
4 kV surge-voltage resistance
Neutral conductor switching
Top or bottom power-supply connection
Integrated overload and short-circuit protection
Integrated residual-current protection
Suitable for compatible three-phase-plus-neutral circuits
Combined protection: Integrates overload, short-circuit and residual-current protection in one device.
63 A rating: Suitable for compatible higher-current three-phase circuits.
Type A protection: Suitable where residual currents may include pulsating DC components.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
D characteristic: Suitable for compatible loads with higher starting or inrush current.
4-pole construction: Suitable for compatible three-phase-plus-neutral systems.
7-module format: Provides a modular four-pole RCBO solution.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
Neutral switching: Supports the four-pole circuit arrangement.
Flexible supply connection: Power can be connected from the top or bottom.
The Siemens 5SU1344-8RC63 combines 63 A overcurrent protection, D-curve tripping and Type A 30 mA residual-current protection in a 4-pole, 7-module RCBO.
The exact Siemens technical data confirms 415 V AC, 50 Hz, 63 A, 4-pole configuration, Type A protection, 30 mA sensitivity, D characteristic and 10 kA EN 61009-1 short-circuit breaking capacity.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type A RCBO for 63 A, 30 mA three-phase circuit protection with D characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1344-8RC63 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 63 A, with 4 poles, 7 modules, D characteristic, Type A residual-current protection and 30 mA sensitivity.
It is an RCBO, meaning it combines residual-current and overcurrent protection in one device.
The rated current is 63 A.
The rated residual operating current is 30 mA.
It uses Type A residual-current protection.
It has a D tripping characteristic.
It has 4 poles, suitable for compatible three-phase-plus-neutral applications.
The exact Siemens technical data specifies 7 modular width units and a physical width of 126 mm.
The exact Siemens datasheet specifies 415 V AC at 50 Hz.
The specified breaking capacity is 10 kA according to EN 61009-1 and 15 kA according to IEC 60947-2.
5SU1344-8RC63: 63 A, 4-pole, Type A, 30 mA, D characteristic.
A corresponding C-characteristic version uses a different article number.
The main difference is the overcurrent tripping characteristic.
Type A can detect suitable AC residual currents and pulsating DC residual-current components, while Type AC is intended for compatible sinusoidal AC residual currents.
The appropriate type should be selected according to the connected equipment.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens Betagard 5SU1 |
|
Part Number |
5SU1344-8RC63 |
|
Product Type |
RCBO (Residual Current Breaker with Overcurrent
Protection) |
|
Residual Current Type |
Type AC |
|
Rated Current |
63 A |
|
Tripping Characteristic |
C Curve |
|
Rated Residual Current |
30 mA (typical series value) |
|
Poles |
4 Pole |
|
Rated Voltage |
400–415 V AC |
|
Frequency |
50/60 Hz |
|
Breaking Capacity |
10 kA |
|
Mounting Type |
DIN Rail |
|
Protection |
Overload, Short Circuit & Earth Leakage |
|
Standard |
IEC 61009-1 / IEC 60947-2 |
|
Application |
Residential, Commercial & Light Industrial |
No reviews yet.