The Siemens 5SU1354-1RC16 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in one compact device. The exact product data specifies a 16 A rated current, 2-pole / 1P+N configuration, 2-module width, C tripping characteristic, Type AC residual-current protection and 30 mA residual operating current. It is rated for 240 V AC at 50 Hz, with a 10 kA short-circuit breaking capacity according to EN 61009-1.
The 5SU1354-1RC16 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. Unlike a conventional RCCB, an RCBO combines multiple protective functions in one device:
Overload protection
Short-circuit protection
Residual-current protection
This integrated arrangement can simplify circuit-level protection and reduce the need for separate MCB and RCCB devices.
Siemens documentation lists 5SU1354-1RC16 within the 5SU1 RCBO range.
The RCBO has a rated current of 16 A.
This makes it suitable for compatible single-phase circuits designed around a 16 A protective device. Final selection should consider the cable capacity, connected load, installation method, ambient temperature and applicable installation requirements.
The exact product data confirms the 16 A operational current at the AC rated value.
The 5SU1354-1RC16 uses a C tripping characteristic.
The C curve is intended for compatible circuits where normal operation may involve moderate starting or inrush currents.
Potential applications include:
Pumps
Fans
Small motors
Contactors
Solenoids
Control transformers
Industrial auxiliary equipment
Selected electrical equipment
The actual tripping characteristic should be selected according to load behaviour and protection coordination. The exact data identifies the device as C characteristic.
The device uses Type AC residual-current protection.
Type AC protection is intended for compatible sinusoidal alternating residual currents.
The leakage-current waveform of the connected equipment should be checked before selecting Type AC. Equipment capable of producing pulsating DC or other residual-current components may require a different residual-current protection type.
The exact Siemens data confirms residual current type AC.
The 5SU1354-1RC16 has a rated residual operating current of 30 mA.
When the residual-current condition reaches the specified operating threshold, the RCBO disconnects the protected circuit.
The 30 mA sensitivity should be selected according to the overall electrical protection design and applicable national requirements.
The exact product data confirms the 30 mA rated tripping fault current.
The device has 2 poles in a 1P+N configuration, with 1 protected pole.
This makes it suitable for compatible single-phase circuits where phase and neutral are incorporated into the switching/protection arrangement.
Typical applications include:
Single-phase distribution boards
Commercial electrical panels
Building electrical systems
Office circuits
Equipment feeders
Industrial auxiliary circuits
Control-panel supplies
The exact technical data specifies a 240 V AC supply voltage and 50 Hz operating frequency.
This makes the article suitable for compatible single-phase AC distribution systems within its specified electrical ratings.
The 5SU1354-1RC16 has a 10 kA short-circuit current breaking capacity according to EN 61009-1.
The technical data also specifies:
10 kA according to EN 60898
20 kA according to IEC 60947-2
10 kA rated residual switching capacity according to IEC 61009-1
Energy limitation class 3
The prospective short-circuit current at the installation point should still be checked during system design.
The exact technical data specifies energy limitation class 3.
This characteristic is relevant when evaluating the RCBO's behaviour under short-circuit conditions within the applicable standard and installation arrangement.
The product is specified as a 2-module RCBO.
Siemens' data gives a physical width of 36 mm and 2 modular width units.
This compact format is useful where electrical-panel space is limited, including:
DIN-rail distribution boards
Commercial panels
Control panels
Sub-distribution boards
Industrial electrical enclosures
The 2-module designation refers to physical panel space and does not indicate a power rating.
The Siemens 5SU1 RCBO family is designed for modular electrical installation.
The 5SU1354-1RC16 can be integrated into compatible distribution boards and electrical panels alongside other DIN-mounted protective and control components.
The exact mounting arrangement should follow Siemens installation instructions and applicable national electrical regulations.
The overcurrent section of the RCBO protects the connected circuit against sustained excessive current caused by overload.
The 16 A rated current should be coordinated with:
Cable ampacity
Connected load
Installation method
Ambient temperature
Protection requirements
Correct coordination helps protect the circuit while minimizing unwanted tripping.
The RCBO also provides integrated short-circuit protection.
Its 10 kA EN 61009-1 breaking capacity should be considered against the prospective fault current at the installation point.
Residual current occurs when part of the electrical current flows through an unintended path, such as leakage to earth.
The RCBO monitors this condition and disconnects the protected circuit when the residual-current operating threshold reaches 30 mA.
This adds residual-current protection to the integrated overload and short-circuit functions.
The C characteristic can be suitable for compatible loads with moderate inrush current.
Potential applications include:
Pumps
Fans
Small motors
Solenoids
Contactors
Control transformers
Industrial auxiliary equipment
Selected commercial equipment
The actual application should be evaluated according to the load's starting-current characteristics.
The 5SU1354-1RC16 is intended for compatible sinusoidal AC residual currents.
For modern electronic equipment containing rectifiers, variable-speed drives or other power electronics, the appropriate residual-current type should be verified before selecting Type AC.
The 5SU1354-1RC16 can be considered for compatible:
Commercial distribution boards
Building electrical panels
Office circuits
Equipment feeders
Industrial auxiliary circuits
Control-panel supplies
Single-phase equipment
Dedicated electrical circuits
The final application should follow the electrical design and applicable standards.
A typical arrangement can be:
Incoming Supply → RCBO → Protected Single-Phase Load
The complete protection design should consider:
Prospective short-circuit current
Cable capacity
Load current
C-curve characteristics
30 mA residual-current sensitivity
Upstream protection
Applicable national installation regulations
The exact technical data specifies that the power-supply connection can be made from either the top or bottom.
This gives practical flexibility during electrical-panel wiring and installation.
The technical data specifies IP20 when the distribution board is installed with connected conductors.
The RCBO should therefore be installed within a suitable electrical enclosure or distribution assembly.
The exact product data specifies:
Operating ambient temperature: -5 °C to +45 °C
Storage temperature: -40 °C to +75 °C
Maximum relative humidity: 95%
These conditions should be considered when selecting the installation location.
The supplied product description states that the device is permitted in all countries and instructs users to observe national installation regulations.
For installations in India, applicable Indian electrical installation requirements and Siemens installation instructions should be followed.
The 5SU1354-7RC16 is the corresponding 16 A, 2-pole, 2-module, C-characteristic, Type A, 30 mA RCBO in the Siemens range.
Therefore:
5SU1354-1RC16 → Type AC, 16 A, 30 mA
5SU1354-7RC16 → Type A, 16 A, 30 mA
The main difference is the residual-current type. Siemens' product documentation lists both article families.
The 5SU1654-1RC16 is the corresponding 16 A, Type AC, C-characteristic, 300 mA configuration.
Therefore:
5SU1354-1RC16 → 16 A, Type AC, 30 mA
5SU1654-1RC16 → 16 A, Type AC, 300 mA
The main difference is the residual-current operating threshold. Siemens documentation lists both article numbers in the 5SU1 range.
The 5SU1354-1RC20 is the corresponding 20 A, 2-pole, 2-module, Type AC, 30 mA, C-characteristic variant.
Therefore:
5SU1354-1RC16 → 16 A
5SU1354-1RC20 → 20 A
The main difference is the rated current. Siemens' product documentation lists both articles.
The 5SU1354-1RC25 is the corresponding 25 A, 2-pole, 2-module, Type AC, 30 mA, C-characteristic RCBO.
Therefore:
5SU1354-1RC16 → 16 A
5SU1354-1RC25 → 25 A
The primary difference is rated current. Siemens documentation lists both articles within the same product family.
The 5SU1354-1RC32 is the corresponding 32 A, 2-pole, 2-module, Type AC, 30 mA, C-characteristic RCBO.
Therefore:
5SU1354-1RC16 → 16 A
5SU1354-1RC32 → 32 A
The correct rated current should be matched to the protected circuit and conductor capacity. Siemens documentation lists both articles.
The 5SU1354-1RC40 is the corresponding 40 A, 2-pole, 2-module, Type AC, 30 mA, C-characteristic RCBO.
Therefore:
5SU1354-1RC16 → 16 A
5SU1354-1RC40 → 40 A
The main difference is rated current. Siemens documentation lists the 16 A and 40 A variants in the same 5SU1 range.
The 5SU1354-1RC16 is an RCBO, not simply an RCCB.
An RCCB primarily provides residual-current protection and normally requires separate overcurrent protection.
An RCBO combines:
Residual-current protection + overload protection + short-circuit protection
in one device.
The Siemens 5SU1354-1RC16 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Facility-maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 16 A, 30 mA single-phase circuit protection with C characteristic.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON / Betagard 5SU1 |
| Article Number | 5SU1354-1RC16 |
| Product Type | Residual Current Circuit Breaker with Overcurrent Protection (RCBO) |
| Rated Current | 16 A |
| Number of Poles | 2 Pole |
| Pole Configuration | 1P+N |
| Protected Poles | 1 |
| Module Width | 2 Modules |
| Physical Width | 36 mm |
| Tripping Characteristic | C Curve |
| Residual Current Type | Type AC |
| Rated Residual Operating Current | 30 mA |
| Rated Operating Voltage | 240 V AC |
| Operating Frequency | 50 Hz |
| Insulation Voltage (Ui) | 264 V |
| Surge Voltage Resistance | 4 V as stated in the product data |
| Short-Circuit Breaking Capacity | 10 kA according to EN 61009-1 |
| EN 60898 Switching Capacity | 10 kA |
| IEC 60947-2 Switching Capacity | 20 kA |
| Rated Residual Switching Capacity | 10 kA |
| Energy Limitation Class | 3 |
| Overvoltage Category | III |
| Pollution Degree | 2 |
| Protection Degree | IP20 when installed in a suitable distribution board |
| Power Supply Position | Top or bottom |
| Height | 90 mm |
| Width | 36 mm |
| Depth | 70 mm |
| Installation Depth | 70 mm |
| Mounting Position | Any |
| Ambient Operating Temperature | -5 °C to +45 °C |
| Storage Temperature | -40 °C to +75 °C |
| Maximum Relative Humidity | 95% |
These specifications are based on the exact Siemens product data for 5SU1354-1RC16.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1354-1RC16
16 A rated current
2-pole / 1P+N configuration
2-module compact format
36 mm physical width
Type AC residual-current protection
30 mA residual-current sensitivity
C tripping characteristic
240 V AC rated supply voltage
50 Hz operating frequency
10 kA EN 61009-1 short-circuit breaking capacity
20 kA IEC 60947-2 switching capacity
10 kA residual switching capacity
Energy limitation class 3
Top or bottom power-supply connection
Suitable for compatible single-phase electrical circuits
Combined protection: Integrates overload, short-circuit and residual-current protection in one device.
16 A rating: Suitable for compatible single-phase circuits.
Type AC protection: Designed for compatible sinusoidal AC residual currents.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
C characteristic: Suitable for compatible loads with moderate inrush current.
2-module design: Helps optimize space in modular distribution boards.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
1P+N configuration: Suitable for compatible phase-and-neutral single-phase circuits.
Flexible supply connection: Allows top or bottom power connection.
Siemens 5SU1 platform: Provides an integrated circuit-protection solution.
The Siemens 5SU1354-1RC16 combines 16 A overcurrent protection, C-curve tripping and Type AC 30 mA residual-current protection in a compact 2-pole, 2-module RCBO.
The exact Siemens data confirms 1P+N configuration, 16 A rated current, 30 mA residual-current sensitivity, Type AC protection, C characteristic, 240 V AC operation and 10 kA EN 61009-1 short-circuit breaking capacity.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 16 A, 30 mA single-phase circuit protection with C characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1354-1RC16 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 16 A, with 2 poles / 1P+N, 2-module width, C characteristic, Type AC residual-current protection and 30 mA sensitivity.
It is an RCBO, combining residual-current and overcurrent protection in one device.
The rated current is 16 A.
The rated residual operating current is 30 mA.
It uses Type AC residual-current protection.
It has a C tripping characteristic.
It has 2 poles in a 1P+N configuration.
It is a 2-module RCBO with a physical width of 36 mm.
The exact technical data specifies 240 V AC at 50 Hz.
The product is specified at 10 kA according to EN 61009-1, with 20 kA according to IEC 60947-2 for the applicable switching-capacity specification.
5SU1354-1RC16: 16 A, Type AC, 30 mA, C characteristic.
5SU1354-7RC16: 16 A, Type A, 30 mA, C characteristic.
The main difference is the residual-current type. Siemens documentation lists both variants.
5SU1354-1RC16: 16 A, Type AC, 30 mA, C characteristic.
5SU1654-1RC16: 16 A, Type AC, 300 mA, C characteristic.
The main difference is the residual-current sensitivity. Siemens documentation lists both articles within the 5SU1 family.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens
Betagard 5SU1 |
|
Part Number |
5SU1354-1RC16 |
|
Product Type |
RCBO (Residual
Current Breaker with Overcurrent Protection) |
|
Residual
Current Type |
Type A |
|
Rated Current |
16 A |
|
Tripping
Characteristic |
C Curve |
|
Rated Residual
Current |
30 mA |
|
Poles |
1P+N (2 Pole) |
|
Rated Voltage |
230–240 V AC |
|
Frequency |
50/60 Hz |
|
Breaking
Capacity |
10 kA |
|
Mounting Type |
DIN Rail |
|
Protection |
Overload, Short
Circuit & Earth Leakage |
|
Standard |
IEC 61009-1 /
IEC 60947-2 |
|
Application |
Residential,
Commercial & Light Industrial |
No reviews yet.