The Siemens 5SU1354-1RC32 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in one compact device. The exact Siemens data identifies it as a 32 A, 2-pole / 1P+N, 2-module, C-characteristic, Type AC, 30 mA RCBO with a 240 V AC supply rating and 10 kA short-circuit breaking capacity according to EN 61009-1.
The 5SU1354-1RC32 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. Unlike a conventional RCCB, an RCBO combines multiple protective functions in a single device:
Overload protection
Short-circuit protection
Residual-current protection
This integrated construction can simplify circuit-level protection and reduce the need for separate MCB and RCCB devices.
Siemens' product documentation lists 5SU1354-1RC32 within the 5SU1 Type AC RCBO range.
The RCBO has a rated current of 32 A.
This makes it suitable for compatible single-phase circuits and feeders designed around a 32 A protective device.
The final selection should consider cable capacity, connected load, installation method, ambient temperature and applicable electrical regulations.
The 5SU1354-1RC32 uses a C tripping characteristic.
The C curve is intended for compatible circuits where normal operation may involve moderate starting or inrush currents.
Potential applications include:
Pumps
Fans
Small motors
Control transformers
Contactors
Solenoids
Industrial auxiliary equipment
Selected electrical equipment
The actual tripping characteristic should be matched to the load and protection-coordination requirements.
The device uses Type AC residual-current protection.
Type AC protection is designed for compatible sinusoidal alternating residual currents.
The residual-current waveform of the connected equipment should be considered before selecting Type AC. Equipment capable of producing pulsating DC or other residual-current components may require a different residual-current protection type.
The exact Siemens data confirms the residual-current type as AC.
The 5SU1354-1RC32 has a rated residual operating current of 30 mA.
When the residual-current condition reaches the specified operating threshold, the RCBO disconnects the protected circuit.
The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable installation requirements.
Siemens' exact product data confirms 30 mA residual-current sensitivity.
The device has 2 poles in a 1P+N configuration.
This makes it suitable for compatible single-phase circuits where phase and neutral are incorporated into the switching/protection arrangement.
Typical applications include:
Single-phase distribution boards
Commercial electrical panels
Building electrical systems
Equipment feeders
Office circuits
Industrial auxiliary supplies
Control-panel circuits
The exact Siemens data specifies 2 poles, 1 protected pole and 1P+N configuration.
The exact product data specifies a 240 V AC supply voltage and 50 Hz operating frequency.
This makes the article suitable for compatible single-phase AC distribution systems within its specified electrical ratings.
The 5SU1354-1RC32 has a 10 kA short-circuit breaking capacity according to EN 61009-1.
The technical data also specifies:
10 kA according to EN 60898
15 kA according to IEC 60947-2
10 kA rated residual switching capacity according to IEC 61009-1
Energy limitation class 3
The prospective short-circuit current at the installation point should still be checked during system design.
The main advantage of the 5SU1354-1RC32 is the integration of multiple protection functions.
A conventional circuit may use:
MCB + RCCB
An RCBO combines these functions:
RCBO = Overload + Short Circuit + Residual Current Protection
This can simplify panel architecture and provide dedicated circuit-level protection.
The exact Siemens data specifies 2 modular width units and a physical width of 36 mm.
The compact 2-module design is suitable for:
DIN-rail distribution boards
Commercial panels
Control panels
Sub-distribution boards
Industrial electrical enclosures
The 2-module designation refers to physical panel space and does not represent a power rating.
The Siemens 5SU1 family is designed for modular electrical-panel installation.
The 5SU1354-1RC32 can be integrated into compatible distribution boards and electrical panels alongside other DIN-mounted protection and control components.
The exact installation should follow Siemens' wiring and mounting instructions as well as applicable national installation regulations.
The RCBO's overcurrent section protects the connected circuit against sustained excessive current caused by overload.
The 32 A rated current should be coordinated with:
Cable ampacity
Load current
Installation method
Ambient temperature
Protection requirements
Correct coordination helps protect the circuit while minimizing nuisance tripping.
The RCBO also provides integrated short-circuit protection.
Its 10 kA EN 61009-1 breaking capacity should be considered against the prospective fault current at the installation point.
Residual current occurs when part of the electrical current flows through an unintended path, such as leakage to earth.
The RCBO monitors this condition and disconnects the protected circuit when the residual-current operating threshold reaches 30 mA.
This adds residual-current protection to the integrated overload and short-circuit functions.
The C characteristic can be suitable for compatible loads with moderate inrush current.
Potential applications include:
Pumps
Fans
Small motors
Solenoids
Contactors
Control transformers
Industrial auxiliary equipment
Selected commercial equipment
The final application should be evaluated according to load starting characteristics.
The 5SU1354-1RC32 is intended for compatible sinusoidal AC residual currents.
For modern electronic equipment containing rectifiers, variable-speed drives or other power electronics, the required residual-current type should be checked before selecting Type AC.
The 5SU1354-1RC32 can be considered for compatible:
Commercial distribution boards
Building electrical panels
Office circuits
Equipment feeders
Industrial auxiliary circuits
Control-panel supplies
Single-phase machinery
Dedicated electrical circuits
The final application should follow the electrical design and applicable regulations.
A typical arrangement can be:
Incoming Supply → RCBO → Protected Single-Phase Load
The complete protection design should consider:
Prospective short-circuit current
Cable capacity
Load current
C-curve characteristics
30 mA residual-current sensitivity
Upstream protection
Applicable electrical standards
The Siemens data specifies IP20 protection when installed in a suitable distribution board with connected conductors. It also specifies that the power supply can be connected from either the top or bottom.
This provides practical flexibility during panel wiring while maintaining the required enclosure protection.
The technical data specifies an operating ambient temperature range of -5 °C to +45 °C and a storage range of -40 °C to +75 °C. Maximum relative humidity is specified at 95%.
These conditions should be considered when installing the device inside electrical panels or distribution boards.
The supplied Siemens product designation explicitly states that the device is permitted in all countries, while also requiring users to observe national installation regulations.
For an India installation, the applicable Indian electrical installation requirements and the manufacturer's installation instructions should therefore be followed.
The 5SU1354-7RC32 is the corresponding 32 A, 2-pole, 2-module, C-characteristic, Type A, 30 mA RCBO in the Siemens range. Siemens' product documentation lists both the Type AC 5SU1354-1RC32 and Type A 5SU1354-7RC32 variants.
Therefore:
5SU1354-1RC32 → Type AC, 32 A, 30 mA
5SU1354-7RC32 → Type A, 32 A, 30 mA
The main difference is the residual-current type.
The 5SU1654-1RC32 is the corresponding 32 A, 2-pole, Type AC, C-characteristic, 300 mA configuration.
Therefore:
5SU1354-1RC32 → 32 A, Type AC, 30 mA
5SU1654-1RC32 → 32 A, Type AC, 300 mA
The principal difference is residual-current sensitivity.
The Siemens Type AC, C-characteristic, 30 mA family also includes the 5SU1354-1RC16.
Therefore:
5SU1354-1RC16 → 16 A
5SU1354-1RC32 → 32 A
The main difference is rated current. Siemens' product range lists both Type AC 1P+N C-characteristic variants.
The same product family includes 5SU1354-1RC25, a 25 A, 1P+N, C-characteristic, Type AC, 30 mA configuration.
Therefore:
5SU1354-1RC25 → 25 A
5SU1354-1RC32 → 32 A
The correct current rating should match the protected circuit and conductor capacity.
The 5SU1354-1RC40 is the corresponding 40 A, 2-pole, Type AC, C-characteristic, 30 mA version. Siemens product documentation lists the article in the same family.
Therefore:
5SU1354-1RC32 → 32 A
5SU1354-1RC40 → 40 A
The 5SU1354-1RC32 is an RCBO.
An RCCB primarily provides residual-current protection and generally requires separate overcurrent protection.
An RCBO combines:
Residual-current protection + overload protection + short-circuit protection
in one device.
The Siemens 5SU1354-1RC32 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Facility-maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 32 A, 30 mA single-phase circuit protection with C characteristic.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1354-1RC32
32 A rated current
2-pole / 1P+N configuration
2-module compact format
Type AC residual-current protection
30 mA residual-current sensitivity
C tripping characteristic
240 V AC rated supply voltage
50 Hz operating frequency
10 kA EN 61009-1 short-circuit breaking capacity
15 kA IEC 60947-2 switching capacity
10 kA residual switching capacity
4 kV surge-voltage resistance
Integrated overload protection
Integrated short-circuit protection
Integrated residual-current protection
Power supply possible from top or bottom
Suitable for compatible single-phase electrical circuits
Combined protection: Integrates overload, short-circuit and residual-current protection in one device.
32 A rating: Suitable for compatible single-phase circuits.
Type AC protection: Designed for compatible sinusoidal AC residual currents.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
C characteristic: Suitable for compatible loads with moderate inrush current.
2-module design: Helps optimize space in modular distribution boards.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
1P+N configuration: Suitable for compatible phase-and-neutral single-phase circuits.
Flexible supply connection: Allows power connection from the top or bottom.
Siemens 5SU1 platform: Provides an integrated circuit-protection solution.
The Siemens 5SU1354-1RC32 combines 32 A overcurrent protection, C-curve tripping and Type AC 30 mA residual-current protection in a compact 2-pole, 2-module RCBO.
The exact Siemens data confirms 1P+N configuration, 32 A rated current, 30 mA residual-current sensitivity, Type AC protection, C characteristic, 240 V AC operation and 10 kA EN 61009-1 short-circuit breaking capacity.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 32 A, 30 mA single-phase circuit protection with C characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1354-1RC32 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 32 A, with 2 poles / 1P+N, 2-module width, C characteristic, Type AC residual-current protection and 30 mA sensitivity.
It is an RCBO, combining residual-current and overcurrent protection in one device.
The rated current is 32 A.
The rated residual operating current is 30 mA.
It uses Type AC residual-current protection.
It has a C tripping characteristic.
It has 2 poles in a 1P+N configuration.
It is a 2-module RCBO with a physical width of 36 mm.
The exact Siemens technical data specifies 240 V AC.
The specified short-circuit breaking capacity is 10 kA according to EN 61009-1, with 15 kA according to IEC 60947-2 for the applicable switching-capacity parameter.
5SU1354-1RC32: 32 A, Type AC, 30 mA, C characteristic.
5SU1354-7RC32: 32 A, Type A, 30 mA, C characteristic.
The main difference is the residual-current type.
5SU1354-1RC32: 32 A, Type AC, 30 mA, C characteristic.
5SU1654-1RC32: 32 A, Type AC, 300 mA, C characteristic.
The main difference is residual-current sensitivity.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens
Betagard 5SU1 |
|
Part Number |
5SU1354-1RC32 |
|
Product Type |
RCBO (Residual
Current Breaker with Overcurrent Protection) |
|
Residual
Current Type |
Type A |
|
Rated Current |
32 A |
|
Tripping
Characteristic |
C Curve |
|
Rated Residual
Current |
30 mA |
|
Poles |
1P+N (2 Pole) |
|
Rated Voltage |
230–240 V AC |
|
Frequency |
50/60 Hz |
|
Breaking
Capacity |
10 kA |
|
Mounting Type |
DIN Rail |
|
Protection |
Overload, Short
Circuit & Earth Leakage |
|
Standard |
IEC 61009-1 /
IEC 60947-2 |
|
Application |
Residential,
Commercial & Light Industrial |
No reviews yet.