The Siemens 5SU1354-7RC16 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in one compact device. The exact product is specified as a 16 A, 2-pole / 1P+N, 2-module, C-characteristic, Type A, 30 mA RCBO. Siemens' current technical data specifies a 10 kA short-circuit rating and 230 V AC rated operating voltage for the corresponding 5SU1354-7KK16 article.
The 5SU1354-7RC16 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. Unlike a conventional RCCB, an RCBO integrates several protective functions in one device:
Overload protection
Short-circuit protection
Residual-current protection
This integrated arrangement can simplify circuit-level protection and reduce the need for separate MCB and RCCB devices.
The exact Indian product description confirms the configuration as 16 A, 2-pole, 2-module, C characteristic, Type A and 30 mA.
The 5SU1354-7RC16 has a rated current of 16 A.
This makes it suitable for compatible single-phase circuits designed around a 16 A protective device. The connected load, cable capacity and installation conditions should always be considered before selecting the RCBO.
Potential applications include:
Lighting circuits
Socket circuits
Control circuits
Instrumentation circuits
Small equipment feeders
Building auxiliary circuits
Industrial control circuits
The RCBO uses a C tripping characteristic.
The C curve is designed for compatible circuits where normal operation can involve moderate starting or inrush current.
Potential applications include:
Small motors
Pumps
Fans
Contactors
Solenoids
Control transformers
Selected lighting equipment
Industrial auxiliary loads
The C characteristic should be matched to the actual load and protection-coordination requirements. Siemens' technical data confirms the C tripping characteristic for the corresponding article.
The 5SU1354-7RC16 provides Type A residual-current protection.
Type A protection is designed to detect suitable AC residual currents as well as pulsating DC residual-current components. This makes it suitable for many modern electrical and electronic loads.
Potential applications include:
Electronic power supplies
Rectifier-based equipment
Automation equipment
Industrial control systems
Modern machinery
Electronic equipment
The exact product is identified as Type A in Siemens' current technical data.
The 5SU1354-7RC16 has a rated residual operating current of 30 mA.
When the residual-current condition reaches the specified operating threshold, the RCBO disconnects the protected circuit.
A 30 mA sensitivity is a specific protection characteristic and should be selected according to the electrical installation design and applicable requirements.
The exact Siemens technical data specifies 30 mA residual-current sensitivity.
The device has 2 poles in a 1P+N configuration.
This makes it suitable for compatible single-phase circuits where phase and neutral are incorporated into the switching/protection arrangement.
Typical applications include:
Single-phase distribution boards
Commercial panels
Building electrical systems
Office circuits
Equipment feeders
Industrial auxiliary circuits
Control-panel supplies
Siemens specifies two poles, one protected pole and a 1P+N design for the corresponding article.
Indian product information identifies the 5SU13547RC16 as a 240 V AC RCBO.
Siemens' current technical data for the corresponding 5SU1354-7KK16 specifies 230 V AC rated operating voltage.
For the SB Smart product page, the supplied India-market 240 V designation can be retained, while installation selection should be based on the exact Siemens technical rating and the electrical system.
The corresponding Siemens technical article is specified as a 10 kA RCBO.
The prospective short-circuit current at the installation point should still be assessed during system design, together with cable protection and upstream coordination.
Because the product is an RCBO, the overcurrent section provides integrated overload and short-circuit protection.
The main advantage of the 5SU1354-7RC16 is the integration of several protection functions in one device.
A conventional arrangement may use:
MCB + RCCB
An RCBO combines these functions:
RCBO = Overload + Short Circuit + Residual Current Protection
This can simplify circuit-level protection and save panel space.
The product is specified as a 2-module RCBO. Indian product listings describe the exact article as a 2-module device, while Siemens' corresponding technical data identifies the 1P+N RCBO in the compact modular format.
A 2-module configuration is approximately 36 mm of standard modular panel space.
This compact format is suitable for:
DIN-rail distribution boards
Consumer units
Commercial panels
Control panels
Sub-distribution boards
Industrial electrical enclosures
The Siemens 5SU1 RCBO family is designed for modular electrical installations.
The 5SU1354-7RC16 can be integrated with compatible DIN-mounted protection and control devices according to the panel design.
The installation should follow Siemens' wiring, mounting and torque requirements.
The overcurrent section of the RCBO protects the circuit against sustained excessive current caused by overload.
The 16 A rated current should be coordinated with the cable size, load current and installation method.
This helps provide appropriate circuit protection while avoiding unnecessary nuisance tripping.
The RCBO also provides integrated short-circuit protection.
The 10 kA short-circuit rating of the corresponding Siemens article should be considered against the prospective fault current at the installation point.
Residual current occurs when part of the electrical current flows through an unintended path, such as leakage to earth.
The RCBO monitors the relevant residual-current condition and disconnects the protected circuit when the specified 30 mA threshold is reached.
This adds residual-current protection to the device's overload and short-circuit functions.
The Type A characteristic makes the 5SU1354-7RC16 suitable for compatible circuits where residual currents can include pulsating DC components.
Potential applications include:
Electronic control panels
Automation systems
Switching power supplies
Rectifier-based equipment
Industrial instrumentation
Modern commercial equipment
The residual-current waveform of the connected equipment should be considered before selecting the RCBO.
The C characteristic can be useful for compatible loads with moderate inrush current.
Potential applications include:
Small pumps
Fans
Small motors
Solenoids
Control transformers
Contactors
Industrial auxiliary equipment
The actual application should be checked against the load's starting-current characteristics.
The 5SU1354-7RC16 can be considered for compatible:
Residential distribution boards
Commercial electrical panels
Office circuits
Building auxiliary systems
Industrial control circuits
Equipment feeders
Automation panels
Single-phase equipment supplies
The final application should follow the electrical design and applicable standards.
A typical arrangement can be:
Incoming Supply → RCBO → Protected Single-Phase Load
The complete protection design should consider:
Prospective short-circuit current
Cable capacity
Load current
C-curve characteristics
30 mA residual-current sensitivity
Upstream protection
Applicable standards
The Siemens technical data specifies a 1P+N configuration, with 2 poles and one protected pole for the corresponding RCBO.
This arrangement is suitable for compatible single-phase circuits requiring phase-and-neutral circuit protection.
RCBOs should be included in an appropriate electrical inspection and testing program.
The test function should be operated according to Siemens' instructions and applicable maintenance requirements to verify correct residual-current operation.
Regular testing helps confirm that the protection mechanism remains operational.
Before selecting the 5SU1354-7RC16, verify:
Rated current: 16 A
Residual-current sensitivity: 30 mA
Residual-current type: Type A
Tripping characteristic: C
Pole configuration: 2-pole / 1P+N
System voltage compatibility
Short-circuit level
Required panel space: 2 modules
Cable size and installation method
Load inrush characteristics
Applicable electrical regulations
The 5SU1654-7RC16 is the corresponding 16 A, 2-pole, Type A, C-characteristic, 300 mA RCBO.
Therefore:
5SU1354-7RC16 → 16 A, Type A, 30 mA
5SU1654-7RC16 → 16 A, Type A, 300 mA
The main difference is the residual-current operating threshold.
The 5SU1654-1RC16 is a 16 A, Type AC, C-characteristic, 300 mA RCBO.
Therefore:
5SU1354-7RC16 → Type A, 16 A, 30 mA
5SU1654-1RC16 → Type AC, 16 A, 300 mA
Both are 5SU1 RCBOs, but the residual-current type and sensitivity differ.
The same Type A, C-characteristic, 30 mA family includes higher-rated variants such as 25 A.
Therefore, the 5SU1354-7RC16 should be selected specifically where the protected circuit requires a 16 A rated protective device.
A 32 A Type A, 30 mA, C-characteristic version is also available in the Siemens 5SU1 range.
The primary difference is rated current:
16 A → 5SU1354-7RC16
32 A → corresponding 5SU1354-7RC32 variant
The selected current rating should match the cable and circuit design.
The 5SU1354-7RC40 is the corresponding 40 A, 2-pole, 2-module, Type A, 30 mA, C-characteristic version.
Therefore:
5SU1354-7RC16 → 16 A
5SU1354-7RC40 → 40 A
The main difference is the rated current.
The 5SU1354-7RC16 uses a C characteristic.
A B-curve protective device is intended for compatible circuits with lower inrush characteristics.
The C characteristic should be selected where the connected load can produce the relevant moderate starting or inrush current.
The 5SU1354-7RC16 is an RCBO, while an RCCB primarily provides residual-current protection.
RCCB → Residual-current protection
RCBO → Residual-current + overload + short-circuit protection
The RCBO therefore provides integrated circuit protection.
The Siemens 5SU1354-7RC16 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Facility-maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens Betagard/SENTRON 5SU1 Type A RCBO for 16 A, 30 mA single-phase circuit protection with C characteristic.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON / Betagard 5SU1 |
| Article Number | 5SU1354-7RC16 |
| Product Type | Residual Current Circuit Breaker with Overcurrent Protection (RCBO) |
| Rated Current | 16 A |
| Number of Poles | 2 Pole |
| Pole Configuration | 1P+N |
| Module Width | 2 Modules |
| Residual Current Type | Type A |
| Rated Residual Operating Current | 30 mA |
| Tripping Characteristic | C Curve |
| Rated Operating Voltage | 230 V AC for corresponding Siemens technical article |
| India Market Designation | 240 V AC |
| Short-Circuit Breaking Capacity | 10 kA |
| Mechanical Service Life | 10,000 operating cycles typical |
| Overvoltage Category | III |
| Application | Single-phase AC circuit protection |
| Installation | Modular / DIN-rail |
These specifications are based on Siemens' current technical data for the corresponding 5SU1354-7KK16, which confirms 10 kA, 1P+N, Type A, 30 mA, C characteristic, 16 A and 230 V AC. The exact India product listing identifies 5SU13547RC16 as 16 A, 2-pole, 2-module, Type A, 30 mA and C characteristic.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1354-7RC16
16 A rated current
2-pole / 1P+N configuration
2-module compact format
Type A residual-current protection
30 mA residual-current sensitivity
C tripping characteristic
230 V AC Siemens technical rating
240 V AC India-market designation
10 kA short-circuit breaking capacity
Integrated overload protection
Integrated short-circuit protection
Integrated residual-current protection
Suitable for compatible single-phase circuits
Designed for modular electrical-panel installation
Combined protection: Integrates overload, short-circuit and residual-current protection in one device.
16 A rating: Suitable for compatible single-phase circuits.
Type A protection: Suitable where residual currents may include pulsating DC components.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
C characteristic: Suitable for compatible loads with moderate inrush current.
2-module format: Helps optimize panel space.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
1P+N configuration: Supports suitable phase-and-neutral single-phase circuits.
Siemens 5SU1 platform: Provides an integrated circuit-protection solution.
The Siemens 5SU1354-7RC16 combines 16 A overcurrent protection, C-curve tripping and Type A 30 mA residual-current protection in a compact 2-pole, 2-module RCBO.
Siemens' current technical data confirms 1P+N configuration, 16 A rated current, Type A, 30 mA, C characteristic, 230 V AC and 10 kA short-circuit capability.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type A RCBO for 16 A, 30 mA single-phase circuit protection with C characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1354-7RC16 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 16 A, with 2 poles / 1P+N, 2-module width, C characteristic, Type A residual-current protection and 30 mA sensitivity.
It is an RCBO, combining residual-current and overcurrent protection in one device.
The rated current is 16 A.
The rated residual operating current is 30 mA.
It uses Type A residual-current protection.
It has a C tripping characteristic.
It has 2 poles in a 1P+N configuration.
It is a 2-module RCBO. The India product listing identifies the exact article as a 2-module device.
Siemens' current technical data specifies 230 V AC, while the Indian product listing identifies the product in the 240 V AC category.
The corresponding Siemens technical article is specified at 10 kA.
5SU1354-7RC16: 16 A, Type A, 30 mA, C characteristic.
5SU1654-7RC16: 16 A, Type A, 300 mA, C characteristic.
The main difference is the residual-current sensitivity.
5SU1354-7RC16: 16 A, Type A, 30 mA, C characteristic.
5SU1654-1RC16: 16 A, Type AC, 300 mA, C characteristic.
Both are 5SU1 RCBOs, but their residual-current type and sensitivity differ.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens
Betagard 5SU1 |
|
Part Number |
5SU1354-7RC16 |
|
Product Type |
RCBO (Residual
Current Breaker with Overload Protection) |
|
Type |
Type A |
|
Rated Current |
16 A |
|
Poles |
1P + N |
|
Tripping Curve |
C
Characteristic |
|
Residual
Current Sensitivity |
30 mA |
|
Rated Voltage |
230/400 V AC |
|
Breaking
Capacity |
10 kA |
|
Mounting Type |
DIN Rail |
|
Standard |
IEC 61009-1 |
|
Application |
Residential
& Light Commercial Distribution |
No reviews yet.