The Siemens 5SU1424-1RC63 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in one compact device. The exact product listing identifies it as a 63 A, 2-pole, 4-module, C-characteristic, Type AC, 100 mA RCBO. Siemens product information and Indian listings confirm the 63 A current rating, 2-pole configuration, Type AC protection, 100 mA sensitivity and C characteristic.
The 5SU1424-1RC63 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. Unlike a conventional RCCB, an RCBO combines several protective functions in one device:
Overload protection
Short-circuit protection
Residual-current protection
This integrated construction can simplify circuit-level protection and reduce the need for separate MCB and RCCB devices.
The exact article is listed with a 63 A rating, 2 poles, 4-module width, C tripping characteristic, Type AC residual-current protection and 100 mA residual-current sensitivity.
The 5SU1424-1RC63 has a rated current of 63 A.
This makes it suitable for compatible higher-current single-phase circuits and feeders where the electrical protection design requires a 63 A protective device.
The final selection should consider:
Connected load
Cable ampacity
Installation method
Ambient conditions
Prospective short-circuit current
Protection coordination requirements
The exact product listing confirms the 63 A rating.
The RCBO uses a C tripping characteristic.
The C curve is intended for compatible circuits where normal operation may involve moderate starting or inrush current.
Potential applications include:
Pumps
Fans
Small motors
Control transformers
Contactors
Solenoids
Industrial auxiliary equipment
Selected equipment feeders
The C characteristic should be selected according to the actual load and protection-coordination requirements.
The exact article is identified with a C curve.
The 5SU1424-1RC63 uses Type AC residual-current protection.
Type AC protection is intended for compatible sinusoidal alternating residual currents.
The actual leakage-current waveform of the connected equipment should be considered before selecting the RCBO. Equipment capable of producing pulsating DC or other residual-current components may require another residual-current type.
The exact product is identified as Type AC.
The 5SU1424-1RC63 has a rated residual operating current of 100 mA.
When the residual-current condition reaches the specified operating threshold, the RCBO disconnects the protected circuit.
The 100 mA sensitivity should be selected according to the complete electrical protection design. It should not automatically be replaced by a 30 mA or 300 mA device because these are different protection configurations.
Indian product specifications confirm 100 mA residual-current sensitivity for this exact article.
The device has 2 poles and is intended for compatible single-phase applications.
The two-pole arrangement allows the phase and neutral circuit arrangement to be incorporated into the protection system according to the manufacturer's wiring configuration.
Typical applications include:
Single-phase distribution boards
Commercial electrical panels
Building electrical systems
Equipment feeders
Office circuits
Industrial auxiliary supplies
Control-panel circuits
Indian product information for the exact 5SU14241RC63 identifies the rated voltage as 240 V AC.
This makes the device suitable for compatible single-phase low-voltage distribution systems where the voltage and protection requirements match the device.
The exact installation voltage should always be checked against the latest Siemens documentation and the electrical-system design.
The exact article is listed with a 10 kA breaking capacity.
The prospective short-circuit current at the installation point should nevertheless be assessed during system design, together with upstream protection and coordination requirements.
Because the device is an RCBO, its overcurrent section also provides short-circuit protection within its specified ratings.
The product designation specifies 4 modules.
The 4-module designation refers to physical panel space and does not indicate a 4 MW power rating.
Indian product data identifies the exact article as a 4-module, 2-pole RCBO.
This format is suitable for:
DIN-rail distribution boards
Commercial panels
Sub-distribution boards
Control panels
Industrial electrical enclosures
The Betagard 5SU1 family is designed for modular electrical installation.
The 5SU1424-1RC63 can be integrated into suitable electrical distribution assemblies alongside compatible protective and control devices.
The panel should provide sufficient space and appropriate mounting arrangements for the device.
The overcurrent section of the RCBO protects the connected circuit against sustained excessive current.
The 63 A rating should be coordinated with:
Cable ampacity
Load current
Installation method
Ambient temperature
Protection requirements
Correct selection helps protect the circuit without unnecessary nuisance tripping.
The RCBO also provides integrated short-circuit protection.
The specified 10 kA breaking capacity should be evaluated against the prospective fault current at the installation point.
The complete electrical protection system should be designed according to applicable standards and installation requirements.
Residual current occurs when a portion of electrical current flows through an unintended path, such as an earth-leakage route.
The RCBO monitors the residual-current condition and disconnects the circuit when the specified 100 mA threshold is reached.
This adds residual-current protection to the integrated overload and short-circuit functions.
The C characteristic can be suitable for compatible loads with moderate inrush current.
Potential applications include:
Pumps
Fans
Small motors
Transformers
Solenoids
Contactors
Industrial auxiliary equipment
Selected commercial equipment
The actual selection should be based on load starting characteristics and protection coordination.
Type AC protection is intended for compatible sinusoidal AC residual currents.
The 5SU1424-1RC63 should therefore be selected where the connected equipment is compatible with Type AC residual-current detection.
For modern electronic equipment, the leakage-current waveform should be evaluated before selecting Type AC instead of Type A, Type F or Type B protection.
The 5SU1424-1RC63 can be considered for compatible:
Commercial distribution boards
Building electrical panels
Equipment feeders
Office circuits
Industrial auxiliary circuits
Control-panel supplies
Single-phase equipment
Dedicated electrical feeders
The final application should follow the electrical-system design and applicable regulations.
A typical arrangement can be:
Incoming Supply → RCBO → Protected Single-Phase Load
The complete protection design should consider:
Prospective short-circuit current
Cable capacity
Load current
C-curve characteristics
100 mA residual-current sensitivity
Upstream protection
Applicable electrical standards
RCBOs should be included in the electrical installation's regular inspection and testing program.
The device test function should be operated according to Siemens' instructions and applicable maintenance requirements to verify residual-current protection.
Regular testing helps confirm that the protective mechanism remains operational.
Before selecting the 5SU1424-1RC63, verify:
Rated current: 63 A
Residual-current sensitivity: 100 mA
Residual-current type: Type AC
Tripping characteristic: C
Pole configuration: 2-pole
Rated voltage: 240 V AC
Short-circuit breaking capacity: 10 kA
Required panel space: 4 modules
Cable size and installation method
Load inrush characteristics
Applicable electrical regulations
The corresponding 5SU1624-1RC63 is the 63 A, 2-pole, 4-module, C-characteristic, Type AC, 300 mA configuration.
Therefore:
5SU1424-1RC63 → 63 A, 100 mA
5SU1624-1RC63 → 63 A, 300 mA
The main difference is the residual-current operating threshold.
The 5SU1424-1RC63 is specifically a 100 mA RCBO.
A 30 mA variant is a different product configuration and should not be treated as an exact replacement without checking the circuit protection requirements.
The exact Type AC article is 5SU1424-1RC63, whereas Type A variants use a different article configuration.
Therefore:
5SU1424-1RC63 → Type AC, 63 A, 100 mA, C
The residual-current type should be selected according to the connected equipment and its leakage-current waveform.
The C characteristic is intended for compatible circuits with moderate inrush current.
A D-characteristic RCBO is intended for compatible circuits with higher starting or inrush currents.
The 5SU1424-1RC63 should therefore be selected specifically where the C characteristic is appropriate.
The 5SU1424-1RC40 is the corresponding 40 A, 2-pole, 4-module, Type AC, 100 mA, C-characteristic RCBO.
Therefore:
5SU1424-1RC40 → 40 A
5SU1424-1RC63 → 63 A
The main difference is the rated current.
The corresponding 32 A variant has a lower rated current while retaining the relevant Type AC, C-characteristic and 100 mA configuration.
The correct rated current should be selected according to the protected circuit and cable design.
The 5SU1444 family contains four-pole RCBOs for compatible three-phase-plus-neutral systems.
The 5SU1424-1RC63 is a 2-pole RCBO for compatible single-phase applications.
Pole configuration should therefore be checked carefully before selecting a replacement.
The 5SU1424-1RC63 is an RCBO, not simply an RCCB.
An RCCB mainly provides residual-current protection and normally requires separate overcurrent protection.
An RCBO combines:
Residual-current protection + overload protection + short-circuit protection
in one device.
The Siemens 5SU1424-1RC63 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Facility-maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens Betagard / SENTRON 5SU1 Type AC RCBO for 63 A single-phase circuit protection with C characteristic and 100 mA sensitivity.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON / Betagard 5SU1 |
| Article Number | 5SU1424-1RC63 |
| Product Type | Residual Current Circuit Breaker with Overcurrent Protection (RCBO) |
| Rated Current | 63 A |
| Number of Poles | 2 Pole |
| Module Width | 4 Modules |
| Tripping Characteristic | C Curve |
| Residual Current Type | Type AC |
| Rated Residual Operating Current | 100 mA |
| Rated Voltage | 240 V AC |
| Rated Frequency | 50 Hz class |
| Short-Circuit Breaking Capacity | 10 kA |
| Installation | Modular / DIN-rail |
| Protection Functions | Overload + Short Circuit + Residual Current |
| Application | Compatible single-phase AC circuit protection |
| Product Family | 5SU1 |
The exact product information confirms 63 A, 2-pole, 4-module, C characteristic, Type AC, 100 mA and 10 kA, while Indian product data specifies 240 V AC.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1424-1RC63
63 A rated current
2-pole configuration
4-module format
Type AC residual-current protection
100 mA residual-current sensitivity
C tripping characteristic
240 V AC rated voltage
10 kA breaking capacity
Integrated overload protection
Integrated short-circuit protection
Integrated residual-current protection
Suitable for compatible single-phase electrical circuits
Designed for modular distribution-board installation
Combined protection: Integrates overload, short-circuit and residual-current protection in one device.
63 A rating: Suitable for compatible higher-current single-phase circuits.
100 mA sensitivity: Provides residual-current protection at the specified operating threshold.
Type AC protection: Designed for compatible sinusoidal AC residual currents.
C characteristic: Suitable for compatible loads with moderate inrush current.
2-pole design: Suitable for compatible single-phase circuit protection.
4-module format: Fits modular electrical-panel arrangements.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
Siemens 5SU1 platform: Provides an integrated circuit-protection solution for electrical installations.
The Siemens 5SU1424-1RC63 combines 63 A overcurrent protection, C-curve tripping and Type AC 100 mA residual-current protection in a 2-pole, 4-module RCBO.
The exact Indian product data confirms the 63 A current rating, 2-pole configuration, 100 mA sensitivity, Type AC protection, C characteristic, 4-module format and 10 kA breaking capacity.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 63 A, 100 mA single-phase circuit protection with C characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1424-1RC63 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 63 A, with 2 poles, 4 modules, C characteristic, Type AC residual-current protection and 100 mA sensitivity.
It is an RCBO, meaning it combines residual-current and overcurrent protection in one device.
The rated current is 63 A.
The rated residual operating current is 100 mA.
It uses Type AC residual-current protection.
It has a C tripping characteristic.
It has 2 poles, making it suitable for compatible single-phase circuit protection.
The 4-module designation refers to the physical panel space occupied by the device. It does not mean a 4 MW power rating. Indian product data identifies the exact article as a 4-module device.
Indian product information specifies 240 V AC for the exact article.
The product is specified with a 10 kA breaking capacity.
5SU1424-1RC40: 40 A, 2-pole, Type AC, 100 mA, C characteristic.
5SU1424-1RC63: 63 A, 2-pole, Type AC, 100 mA, C characteristic.
The main difference is the rated current.
5SU1424-1RC63: 63 A, 2-pole, Type AC, 100 mA, C characteristic.
5SU1624-1RC63: 63 A, 2-pole, Type AC, 300 mA, C characteristic.
The main difference is the residual-current sensitivity.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens
Betagard 5SU1 |
|
Part Number |
5SU1424-1RC41 |
|
Product Type |
RCBO (Residual
Current Breaker with Overload Protection) |
|
Type |
Type AC |
|
Rated Current |
40 A |
|
Poles |
2 Pole (1P+N) |
|
Tripping Curve |
C
Characteristic |
|
Residual
Current Sensitivity |
30 mA / 100 mA
(variant dependent) |
|
Rated Voltage |
230/400 V AC |
|
Breaking
Capacity |
10 kA |
|
Mounting Type |
DIN Rail |
|
Standard |
IEC 61009-1 |
|
Application |
Residential,
Commercial & Light Industrial |