The Siemens 5SU1644-1RC63 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in one device. The exact product designation identifies it as a 63 A, 4-pole, Type AC, 300 mA, C-characteristic RCBO for three-phase-plus-neutral applications. The current product datasheet specifies 415 V AC, 10 kA breaking capacity according to EN 61009-1, and Type AC residual-current protection.
The 5SU1644-1RC63 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. Unlike an RCCB, which primarily provides residual-current protection and normally requires separate overcurrent protection, an RCBO combines multiple protective functions in one device.
It provides protection against:
Overload
Short circuit
Residual or earth-leakage current
This integrated design can simplify circuit-level protection and reduce the number of separate protective devices required in an electrical panel.
The exact Indian product designation identifies the device as a 63 A, 4-pole, 8-module, C-characteristic, Type AC, 300 mA RCBO.
The RCBO has a rated current of 63 A.
This makes it suitable for compatible three-phase circuits and feeders designed around a 63 A protective device.
The final current rating should be selected according to the connected load, conductor capacity, installation method, ambient conditions and applicable electrical regulations.
The 5SU1644-1RC63 uses a C tripping characteristic.
The C curve is intended for circuits where normal operation can involve moderate starting or inrush currents.
Suitable applications may include compatible:
Motors
Pumps
Fans
Control transformers
Contactors and solenoids
Industrial equipment
Selected lighting and electronic loads
The C characteristic should be selected according to the actual load and protection-coordination requirements.
The RCBO uses Type AC residual-current protection.
Type AC devices are intended for compatible sinusoidal alternating residual currents. The residual-current characteristics of the connected equipment should always be considered before selecting the protection type.
For equipment that can produce pulsating DC or other residual-current waveforms, a different RCBO type may be required.
The exact product data identifies the residual-current type as AC.
The 5SU1644-1RC63 has a rated residual operating current of 300 mA.
When the residual-current condition reaches the specified operating threshold, the RCBO disconnects the protected circuit.
The 300 mA sensitivity should be selected according to the complete electrical protection design. It should not automatically be substituted with a 30 mA device because the two have different residual-current operating thresholds.
The RCBO has 4 poles, making it suitable for compatible three-phase plus neutral electrical systems.
The four-pole arrangement allows the relevant three phases and neutral to be incorporated into the circuit protection arrangement.
Typical applications include:
Three-phase distribution boards
Industrial feeder circuits
PCC panels
MCC panels
Commercial electrical panels
Machine power circuits
Factory electrical systems
Sub-distribution boards
The exact technical datasheet specifies a 415 V AC supply voltage and 50 Hz operating frequency for the 5SU1644-1RC63.
This makes it suitable for compatible three-phase low-voltage distribution systems where the system voltage and protection requirements match the device.
The technical data specifies a 10 kA short-circuit breaking capacity according to EN 61009-1. It also specifies 15 kA according to IEC 60947-2 for the relevant switching-capacity parameter.
The prospective short-circuit current at the installation point should still be evaluated during system design, and the RCBO should be installed according to the manufacturer's coordination requirements.
One of the main benefits of the 5SU1644-1RC63 is the integration of several protection functions.
A conventional circuit may use:
MCB + RCCB
An RCBO combines these functions:
RCBO = Overload + Short Circuit + Residual Current Protection
This can simplify electrical-panel architecture and provide dedicated protection to an individual three-phase circuit.
The supplied product description identifies the article as an 8-module RCBO. Indian listings also describe the product as an 8-module unit.
There is an important dimensional distinction in the current technical datasheet: it lists 7 modular width units and a physical width of 126 mm for the corresponding article.
Therefore, for the SB Smart product page, the official article description "8 modules" should be retained in the product title, while the physical modular-width specification should be stated separately as per the current datasheet.
The device is designed for modular electrical-panel installation.
With its four-pole construction and integrated RCBO functions, it can be used in appropriately sized:
Distribution boards
Industrial control panels
PCC panels
MCC panels
Machine panels
Commercial switchboards
Factory electrical enclosures
The available panel space should be checked before installation.
The RCBO's overcurrent protection function protects the circuit against excessive current caused by sustained overload.
The 63 A rating should be coordinated with the cable size, connected load and installation conditions.
Correct circuit coordination helps avoid both inadequate protection and unnecessary nuisance tripping.
The RCBO also provides short-circuit protection.
Its specified breaking capacity should be considered against the prospective fault current at the point of installation. The current datasheet specifies 10 kA according to EN 61009-1.
Residual current occurs when part of the electrical current flows outside its intended circuit path, such as through an unintended earth-leakage path.
The RCBO monitors the residual-current condition and disconnects the circuit when the specified 300 mA operating threshold is reached.
This provides residual-current protection in addition to the integrated overload and short-circuit protection.
The 5SU1644-1RC63 can be considered for compatible:
Industrial distribution boards
Three-phase equipment feeders
PCC panels
MCC panels
Machine power circuits
Commercial switchboards
Factory electrical systems
Sub-distribution boards
Building electrical panels
The final application should be determined according to the electrical design and applicable standards.
The C characteristic makes the device suitable for compatible loads where moderate starting current or inrush current can occur.
Potential applications include:
Small and medium motor circuits
Pumps
Fans
Control transformers
Solenoids
Industrial machinery
Selected automation equipment
The actual suitability depends on the load's starting characteristics and protection-coordination requirements.
Type AC protection is intended for compatible sinusoidal AC residual currents.
The 5SU1644-1RC63 should therefore be selected where the connected equipment is compatible with Type AC residual-current detection.
For modern equipment incorporating rectifiers, variable-speed drives or power electronics, the appropriate residual-current type should be verified from the equipment documentation.
A typical circuit arrangement can be:
Incoming Supply → RCBO → Protected Three-Phase Load
Because the RCBO already integrates overcurrent protection, the complete installation still needs to be coordinated with the upstream protective arrangement and system fault level.
Correct coordination should consider:
Prospective short-circuit current
Cable capacity
Load current
RCBO characteristics
Upstream protection
Applicable electrical standards
RCBOs should be included in the electrical installation's regular inspection and testing program.
The test function should be operated according to Siemens' instructions and applicable maintenance requirements to verify the residual-current protection function.
Regular testing helps confirm that the protective mechanism remains operational.
Before selecting the 5SU1644-1RC63, verify:
Rated current: 63 A
Residual-current sensitivity: 300 mA
Residual-current type: Type AC
Tripping characteristic: C
Pole configuration: 4-pole
Rated voltage: 415 V AC
Operating frequency: 50 Hz
Short-circuit capacity: 10 kA according to EN 61009-1
Required panel space
Cable size and installation method
Connected equipment characteristics
Applicable electrical regulations
The 5SU1644-2RC63 is the corresponding 63 A, 4-pole, Type AC, 300 mA RCBO with a D characteristic.
Therefore:
5SU1644-1RC63 → C characteristic
5SU1644-2RC63 → D characteristic
The principal difference is the overcurrent tripping characteristic.
The C curve is intended for moderate inrush applications, while the D curve is intended for circuits with higher starting or inrush currents.
A Type A variant should be selected where the installation requires detection of suitable residual currents containing pulsating DC components.
The 5SU1644-1RC63 is specifically Type AC, so it should not be directly substituted with a Type A or Type B device without checking the residual-current characteristics of the connected equipment.
The Siemens 5SU1 range contains Type A RCBO variants with similar current and characteristic combinations.
The key distinction for this article is:
5SU1644-1RC63 → Type AC + C characteristic + 63 A + 300 mA
This combination should be checked carefully when sourcing an exact replacement.
The 5SU1644-1RC63 is specifically a 300 mA residual-current device.
Where a circuit design requires a 30 mA threshold, a separate article must be selected. A lower residual-current threshold should not be substituted without confirming the protection requirements.
The 5SU1644-1RC32 is the corresponding 32 A, 4-pole, Type AC, 300 mA, C-characteristic RCBO family variant.
Therefore:
5SU1644-1RC32 → 32 A
5SU1644-1RC63 → 63 A
The principal difference is the rated current.
A lower-current variant should be selected where the protected circuit requires less than 63 A.
The 5SU1644-1RC63 is specifically selected for circuits requiring a 63 A C-characteristic Type AC RCBO with 300 mA sensitivity.
The Siemens 5SU1644-1RC63 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Factory maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens SENTRON / Betagard 5SU1 Type AC RCBO for 63 A three-phase circuit protection with C characteristic.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON / Betagard 5SU1 |
| Article Number | 5SU1644-1RC63 |
| Product Type | Residual Current Circuit Breaker with Overcurrent Protection (RCBO) |
| Rated Current | 63 A |
| Number of Poles | 4 Pole / 4P |
| Tripping Characteristic | C Curve |
| Residual Current Type | Type AC |
| Rated Residual Operating Current | 300 mA |
| Rated Operating Voltage | 415 V AC |
| Rated Frequency | 50 Hz |
| Short-Circuit Breaking Capacity | 10 kA according to EN 61009-1 |
| IEC 60947-2 Switching Capacity | 15 kA |
| Residual Switching Capacity | 10 kA |
| Energy Limitation Class | 3 |
| Insulation Voltage (Ui) | 440 V |
| Surge Voltage Resistance | 4 kV |
| Overvoltage Category | III |
| Pollution Degree | 2 |
| Protection Degree | IP20, when installed in suitable distribution-board conditions |
| Neutral Conductor Switching | Yes |
| Power Supply Position | Top or bottom |
| Mounting Position | Any |
| Physical Width | 126 mm |
| Datasheet Modular Width | 7 modular width units |
The exact product datasheet provides these technical values for 5SU1644-1RC63. Indian product listings identify the marketed product as 63 A, 4-pole, 8 modules, Type AC, 300 mA, C characteristic, 415 V AC.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1644-1RC63
63 A rated current
4-pole configuration
Type AC residual-current protection
300 mA residual-current sensitivity
C tripping characteristic
415 V AC rated voltage
50 Hz operating frequency
10 kA EN 61009-1 short-circuit breaking capacity
15 kA IEC 60947-2 switching capacity
10 kA residual switching capacity
440 V insulation voltage
4 kV surge-voltage resistance
Neutral conductor switching
Top or bottom power-supply connection
Modular electrical-panel installation
Combined protection: Provides overload, short-circuit and residual-current protection in one RCBO.
63 A rating: Suitable for compatible higher-current three-phase circuits.
Type AC protection: Designed for compatible sinusoidal AC residual currents.
300 mA sensitivity: Provides residual-current protection at the specified operating threshold.
C characteristic: Suitable for compatible loads with moderate inrush current.
4-pole configuration: Suitable for compatible three-phase-plus-neutral circuits.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within its specified standard.
Neutral switching: Supports phase and neutral circuit switching.
Flexible power supply: Power can be connected from the top or bottom according to the product design.
The Siemens 5SU1644-1RC63 combines 63 A overcurrent protection, C-curve tripping and Type AC 300 mA residual-current protection in a four-pole RCBO.
The exact technical datasheet confirms 415 V AC operation, 50 Hz frequency, 300 mA residual-current sensitivity, C characteristic, 4-pole configuration and 10 kA EN 61009-1 short-circuit breaking capacity.
It is suitable for customers looking to buy or source Siemens 5SU1 RCBOs for industrial distribution boards, three-phase equipment feeders, electrical panels, machine circuits and commercial installations in India.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 63 A, 300 mA three-phase circuit protection with C characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1644-1RC63 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 63 A, with 4 poles, C characteristic, Type AC residual-current protection and 300 mA sensitivity.
It is an RCBO, meaning it combines residual-current and overcurrent protection in one device.
The rated current is 63 A.
The rated residual operating current is 300 mA.
It uses Type AC residual-current protection.
It has a C tripping characteristic.
It has 4 poles, suitable for compatible three-phase-plus-neutral applications.
The exact datasheet specifies 415 V AC rated supply voltage and 50 Hz frequency.
The datasheet specifies 10 kA according to EN 61009-1 and 15 kA according to IEC 60947-2 for the relevant switching-capacity specification.
5SU1644-1RC63: 63 A, 4-pole, C characteristic, Type AC, 300 mA.
5SU1644-2RC63: 63 A, 4-pole, D characteristic, Type AC, 300 mA.
The main difference is the overcurrent tripping characteristic.
5SU1644-1RC63: 63 A, 4-pole, Type AC, 300 mA, C characteristic.
5SU1644-1RC32: 32 A, 4-pole, Type AC, 300 mA, C characteristic.
The main difference is the rated current.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens
Betagard 5SU1 |
|
Part Number |
5SU1644-1RC63 |
|
Product Type |
RCBO (Residual
Current Breaker with Overload Protection) |
|
Type |
Type AC |
|
Rated Current |
63 A |
|
Tripping Curve |
C
Characteristic |
|
Poles |
4 Pole (4P) |
|
Rated Voltage |
415 V AC |
|
Frequency |
50 Hz |
|
Residual
Current Protection |
Earth leakage
protection |
|
Mounting Type |
DIN Rail |
|
Degree of
Protection |
IP20 |
|
Standard |
IEC 61009-1 |
|
Application |
Commercial
& Industrial Distribution |
No reviews yet.