The Siemens 5SU1654-1RC16 is a SENTRON / Betagard RCBO (Residual Current Circuit Breaker with Overcurrent Protection) designed to combine residual-current protection and overcurrent protection in one compact device. The exact Siemens market-facing article is specified as 16 A, 2-pole, 2-module, C characteristic, Type AC, 300 mA, with a 240 V AC supply rating.
This RCBO is suitable for compatible single-phase electrical circuits where protection against overload, short circuit and AC residual current is required in a compact modular format.
The 5SU1654-1RC16 belongs to the Siemens SENTRON 5SU1 RCBO family. Unlike an RCCB, which primarily provides residual-current protection, an RCBO combines multiple protective functions in a single device.
It provides:
Overload protection
Short-circuit protection
Residual-current protection
This integrated approach can simplify electrical-panel design and reduce the need for separate MCB and RCCB devices.
Siemens' product-family information lists the 5SU1654-1RC16 among its 5SU1 RCBO articles.
The 5SU1654-1RC16 has a rated current of 16 A.
This makes it suitable for compatible single-phase circuits designed around a 16 A protective device.
The final selection should consider:
Connected load
Cable size
Installation method
Ambient conditions
Fault level
Applicable electrical regulations
The RCBO uses a C tripping characteristic.
A C-curve protective device is generally suitable for circuits where normal operation can involve moderate inrush currents.
Potential applications include:
Small motors
Fans
Pumps
Solenoids
Control transformers
Contactors
Suitable lighting equipment
Industrial auxiliary circuits
The C characteristic should always be matched to the connected load and protection-coordination requirements.
The 5SU1654-1RC16 uses Type AC residual-current protection.
Type AC RCCB/RCBO devices are intended for compatible sinusoidal alternating residual currents. The exact residual-current waveform of the connected equipment should be evaluated before selecting the protection type.
The Siemens 5SU1654-1RC16 data identifies the product specifically as Type AC.
The rated residual operating current is 300 mA.
When the residual current reaches the applicable operating threshold, the RCBO's residual-current protection function disconnects the circuit.
The 300 mA sensitivity should be selected according to the overall electrical protection design. It should not automatically be replaced by a 30 mA device, as the two have different protection characteristics.
The exact product data confirms 300 mA residual-current sensitivity.
The device has 2 poles, with 1 protected pole and neutral switching, corresponding to a 1P+N configuration.
This makes it suitable for compatible single-phase circuits in which phase and neutral are incorporated into the switching arrangement.
Typical applications include:
Single-phase distribution boards
Commercial panels
Building electrical systems
Equipment feeders
Office circuits
Industrial auxiliary circuits
Control-panel supplies
The exact Siemens 5SU1654-1RC16 data specifies a 240 V AC operating supply.
This makes the article suitable for compatible single-phase AC distribution systems within its specified installation conditions.
The exact 5SU1654-1RC16 data specifies a 10 kA short-circuit breaking capacity according to EN 61009-1, with a 20 kA value according to IEC 60947-2 in the technical data.
The applicable rating should be interpreted according to the relevant standard and installation arrangement.
The prospective short-circuit current at the installation point should still be checked during system design.
The product is specified as a 2-module RCBO.
The exact technical data gives a width of approximately 36 mm, corresponding to two modular units.
This compact design is useful where electrical-panel space is limited.
Typical installation locations include:
Modular distribution boards
Consumer units
Commercial panels
Control panels
Sub-distribution boards
Industrial electrical enclosures
The 5SU1 RCBO family is designed for modular electrical installations.
The 2-module form factor allows the RCBO to be integrated with compatible MCBs, busbars and other DIN-mounted components according to the panel design.
The RCBO's overcurrent protection function provides protection against excessive current caused by circuit overload.
The 16 A rated current should be coordinated with the cable capacity and connected load.
This helps protect the circuit from sustained overcurrent conditions.
The overcurrent section also provides short-circuit protection.
The specified 10 kA EN 61009-1 breaking capacity should be considered in relation to the prospective fault current of the installation.
The complete protection arrangement should be designed according to the relevant electrical standard.
Residual current occurs when a portion of current flows outside its intended circuit path, such as through an unintended leakage path to earth.
The RCBO monitors this condition and disconnects the circuit when the residual-current operating threshold is reached.
With Type AC, 300 mA residual-current protection, the device is intended for compatible AC leakage-current applications.
The C characteristic can be useful for circuits with moderate starting or inrush current.
Potential applications include:
Small motors
Pumps
Fans
Solenoids
Contactors
Transformers
Selected lighting circuits
Control equipment
The actual application should be checked against the load's starting characteristics.
The 5SU1654-1RC16 can be considered for compatible:
Commercial distribution boards
Building electrical panels
Equipment feeders
Control circuits
Office electrical installations
Small industrial circuits
Machine auxiliary circuits
Single-phase equipment supplies
The 5SU1654-1RC16 is an RCBO, so it combines residual-current and overcurrent protection.
In comparison:
RCCB → Residual-current protection
RCBO → Residual-current + overload + short-circuit protection
This integrated design can simplify circuit-level protection and reduce panel component count.
The 5SU1654-1RC25 is the higher-rated 25 A version with the same general 2-pole, 2-module, C characteristic, Type AC, 300 mA configuration. Siemens India lists this exact article with the same product description structure.
Therefore:
5SU1654-1RC16 → 16 A
5SU1654-1RC25 → 25 A
The main difference is rated current.
The 5SU1654-1RC32 is the 32 A version within the same general product family.
Therefore:
5SU1654-1RC16 → 16 A
5SU1654-1RC25 → 25 A
5SU1654-1RC32 → 32 A
The correct rating should be selected according to the protected circuit.
The 5SU1654-7RC16 is a Type A variant in the Siemens 5SU1 family, while 5SU1654-1RC16 is specifically Type AC.
Therefore:
5SU1654-1RC16 → Type AC, 16 A, 300 mA
5SU1654-7RC16 → Type A, 16 A, 300 mA
The principal difference is the residual-current type.
Siemens also offers 5SU1 RCBO variants with lower residual-current sensitivity such as 30 mA.
The 5SU1654-1RC16 is specifically the 300 mA version.
A 30 mA RCBO should therefore not be treated as an exact substitute without checking the protection requirements of the installation.
The C characteristic is intended for compatible circuits with moderate inrush current.
B-characteristic RCBOs are generally selected for circuits with lower inrush characteristics.
The 5SU1654-1RC16 should be selected specifically when the protection design requires the C tripping characteristic.
The Siemens 5SU1654-1RC16 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
Commercial electrical contractors
Facility-maintenance teams
OEMs
Machine builders
Electrical distributors
Building-services contractors
Electrical product dealers
For SB Smart, the product is positioned as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 16 A single-phase circuit protection.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1654-1RC16
16 A rated current
2-pole / 1P+N
2-module compact design
36 mm device width
Type AC residual-current protection
300 mA residual-current sensitivity
C tripping characteristic
240 V AC supply
50 Hz operating frequency
10 kA short-circuit breaking capacity according to EN 61009-1
Neutral conductor switching
Power supply possible from top or bottom
Suitable for single-phase modular circuit protection
Combined protection: Provides overload, short-circuit and residual-current protection in one device.
16 A rating: Suitable for compatible single-phase circuits.
Type AC protection: Designed for compatible sinusoidal AC residual currents.
300 mA sensitivity: Provides residual-current protection at the specified threshold.
C characteristic: Suitable for compatible loads with moderate inrush current.
2-module design: Helps optimize electrical-panel space.
36 mm width: Provides a compact modular solution.
10 kA breaking capacity: Supports high fault-level applications within the specified standard and installation conditions.
Neutral switching: Provides 1P+N switching functionality.
Top or bottom supply: Offers installation flexibility.
The Siemens 5SU1654-1RC16 combines 16 A overcurrent protection, C-curve tripping and Type AC 300 mA residual-current protection in a compact 2-pole, 2-module RCBO.
The exact Siemens technical data confirms 240 V AC operation, 1P+N configuration, Type AC residual-current protection, 300 mA sensitivity, C characteristic and 10 kA EN 61009-1 breaking capacity.
It is suitable for customers looking to buy or source Siemens 5SU1 RCBOs for single-phase electrical panels, distribution boards, equipment circuits and commercial or industrial applications in India.
For SB Smart, this product is best presented as a Siemens Betagard 5SU1 Type AC RCBO for 16 A, 300 mA single-phase circuit protection across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1654-1RC16 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 16 A, with 2 poles / 1P+N, 2-module width, C characteristic, Type AC and 300 mA residual-current sensitivity.
It is an RCBO, meaning it combines residual-current and overcurrent protection.
The rated current is 16 A.
The rated residual operating current is 300 mA.
It uses Type AC residual-current protection.
It has a C tripping characteristic.
It has 2 poles in a 1P+N configuration.
It is a 2-module device with a width of approximately 36 mm.
The exact product data specifies 240 V AC.
The datasheet specifies 10 kA according to EN 61009-1, with 20 kA according to IEC 60947-2.
5SU1654-1RC16: 16 A, Type AC, 300 mA, C characteristic.
5SU1654-7RC16: 16 A, Type A, 300 mA, C characteristic.
The key difference is the residual-current type.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, OEMs, commercial installations and maintenance requirements.
|
Parameter |
Specification |
|
Product
Series |
Siemens
Betagard 5SU1 |
|
Part
Number |
5SU1654-1RC16 |
|
Product
Type |
RCBO
(Residual Current Breaker with Overload Protection) |
|
Type |
Type
AC |
|
Rated
Current |
16
A |
|
Tripping
Curve |
C
Characteristic |
|
Poles |
4
Pole (4P) |
|
Rated
Voltage |
415
V AC |
|
Frequency |
50
Hz |
|
Residual
Current Protection |
Earth leakage
protection |
|
Mounting
Type |
DIN
Rail |
|
Degree
of Protection |
IP20 |
|
Standard |
IEC
61009-1 |
|
Application |
Commercial
& Industrial Distribution |
No reviews yet.