The Siemens 5SV3312-6RC is a SENTRON 5SV3 Residual Current Operated Circuit Breaker (RCCB) designed for residual-current protection in suitable single-phase AC electrical installations. It is a 2-pole / 1+N, Type A RCCB with a 25 A rated current and 30 mA rated residual operating current. Siemens identifies the corresponding article 5SV3312-6 as an active 2-pole Type A RCCB, In 25 A, 30 mA, Un AC 230 V.
The supplied India product designation specifies 240 V and 2MW, making this model suitable for compatible single-phase distribution boards, electrical panels and feeder circuits.
The 5SV3312-6RC belongs to the Siemens SENTRON 5SV3 RCCB family. Its primary function is to detect residual current in the protected circuit and disconnect the circuit when the residual-current level reaches the specified operating threshold.
The 2-pole / 1+N configuration is intended for suitable single-phase systems where phase and neutral are incorporated into the residual-current protection arrangement.
Siemens' product catalogue identifies the corresponding 5SV3312-6 as a 2-pole, Type A, 25 A, 30 mA, 230 V AC RCCB and lists it as an active product.
The RCCB has a rated current of 25 A.
This makes it suitable for compatible single-phase circuits and feeders where a 25 A residual-current protection device is required.
The protected circuit should be designed so that the RCCB operates within its specified electrical ratings and installation conditions.
The 5SV3312-6RC has a rated residual operating current of 30 mA. Siemens technical data confirms the 30 mA tripping residual current and 25 A rated current.
When residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.
The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable installation requirements.
The device is a Type A RCCB.
Type A residual-current protection is designed to detect suitable AC residual currents as well as pulsating DC residual-current components. This makes Type A devices useful for installations containing modern electronic and rectifier-based loads.
Potential applications include:
Electronic power supplies
Rectifier-based equipment
Automation equipment
Variable-speed equipment
Industrial electronic machinery
Modern commercial electrical equipment
The correct RCCB type should always be selected according to the residual-current characteristics of the connected equipment.
The 5SV3312-6RC has 2 poles and is intended for 1+N single-phase applications.
This arrangement allows the phase and neutral conductors to be incorporated into the residual-current protection system.
Typical applications include:
Single-phase distribution boards
Commercial electrical panels
Building electrical installations
Office electrical systems
Equipment feeders
Sub-distribution circuits
Industrial auxiliary circuits
The supplied India product designation identifies the device as 240 V, 2MW.
Siemens' official product data for 5SV3312-6 specifies 230 V AC rated operating voltage.
For the SB Smart product page, the 240 V India-market designation can be retained, while the exact Siemens technical rating should be considered when selecting the device for an installation.
The 5SV3312-6RC is an instantaneous RCCB. Siemens' technical data specifies that the switching function is not short-time delayed.
This means the device responds without an intentionally introduced short-time delay when the specified residual-current threshold is reached.
The corresponding Siemens 5SV3312-6 has a specified 10 kA short-circuit current rating. Siemens also specifies a maximum permissible 63 A series fuse for short-circuit protection coordination.
The RCCB should nevertheless be coordinated with suitable upstream overcurrent protection and the prospective short-circuit conditions of the installation.
An RCCB primarily provides residual-current protection and should not be treated as a substitute for an MCB or MCCB for overload and short-circuit protection unless the complete protection arrangement specifically provides those functions.
The India product description specifies 2MW, meaning 2 module width.
The 2MW designation refers to the physical modular width and does not indicate a 2 MW power rating. Siemens' product-selection data places the Type A 1P+N 25 A, 30 mA device within the 2-module format.
This compact format is suitable for:
Modular distribution boards
Consumer units
Commercial electrical panels
Sub-distribution boards
Compact electrical enclosures
The 5SV3312-6RC is designed for modular electrical installation.
Siemens technical data identifies the corresponding device as size 1 according to DIN 43880, with a physical width of approximately 36 mm and a 60 mm grid spacing.
This allows convenient integration into suitable DIN-type distribution assemblies alongside compatible MCBs, busbars and other protection accessories.
Siemens specifies IP20 protection when the device is installed in a suitable distribution board with connected conductors.
The RCCB should therefore be installed inside an appropriate electrical enclosure or distribution assembly.
Residual current occurs when part of the electrical current flows through an unintended path, such as leakage to earth.
The RCCB monitors the relevant current balance and disconnects the protected circuit when the residual current reaches the configured 30 mA threshold.
This provides an additional layer of residual-current protection within the complete electrical safety system.
The Type A characteristic makes the 5SV3312-6RC suitable for compatible installations where residual currents may include pulsating DC components.
Potential applications include:
Industrial automation equipment
Electronic control panels
Rectifier-based machinery
Variable-speed equipment
Commercial electronic systems
Modern machine installations
Power-electronic loads
The actual suitability should be verified against the residual-current characteristics of the connected equipment.
The 5SV3312-6RC can be considered for compatible single-phase applications such as:
Residential distribution boards
Commercial electrical panels
Building electrical systems
Office electrical circuits
Equipment supply circuits
Single-phase feeder protection
Industrial auxiliary circuits
The final protection application should be determined according to the electrical design and applicable regulations.
An RCCB should be coordinated with suitable overcurrent protection where required.
A typical arrangement can be:
Incoming Supply → MCB/MCCB → RCCB → Protected Load
The exact configuration depends on the electrical system, upstream protective device and applicable installation requirements.
The RCCB's residual-current protection function should be considered separately from overload and short-circuit protection.
RCCBs should be included in an appropriate electrical inspection and testing program.
The test function should be operated according to the manufacturer's instructions and applicable maintenance requirements to verify correct residual-current tripping.
Regular testing can help confirm that the protection mechanism remains operational.
Before selecting the 5SV3312-6RC, verify:
Rated current: 25 A
Residual-current sensitivity: 30 mA
RCCB type: Type A
Pole arrangement: 2-pole / 1+N
System voltage compatibility
Upstream overcurrent protection
Available panel space: 2 module width
Conductor size and termination
Connected equipment leakage-current characteristics
Applicable national electrical regulations
The RCCB type should be selected according to the actual load and residual-current waveform.
The 5SV4312-0RC is a 25 A, 2-pole / 1+N, Type AC, 30 mA RCCB, whereas the 5SV3312-6RC is a 25 A, Type A, 30 mA RCCB.
Therefore:
5SV3312-6RC → Type A, 25 A, 30 mA
5SV4312-0RC → Type AC, 25 A, 30 mA
The main difference is the residual-current type.
The 5SV3314-6RC is the corresponding 40 A, 2-pole / 1+N, Type A, 30 mA version.
Therefore:
5SV3312-6RC → 25 A
5SV3314-6RC → 40 A
Both use the Type A, 1P+N and 30 mA configuration. Siemens' product-selection data lists both current ratings in this family.
The 5SV3316-6 is the corresponding 63 A, 2-pole / 1+N, Type A, 30 mA device.
Therefore:
5SV3312-6RC → 25 A
5SV3314-6RC → 40 A
5SV3316-6 → 63 A
The primary difference is the rated current.
The 5SV3317-6 belongs to the corresponding 80 A, 2-pole / 1+N, Type A, 30 mA range.
Therefore:
5SV3312-6RC → 25 A
5SV3314-6RC → 40 A
5SV3316-6 → 63 A
5SV3317-6 → 80 A
These models share the Type A, 1P+N and 30 mA configuration while differing in rated current.
The 5SV3412-6 is the corresponding 25 A, 2-pole / 1+N, Type A, 100 mA device.
Therefore:
5SV3312-6RC → 25 A, 30 mA
5SV3412-6 → 25 A, 100 mA
The main difference is the residual-current operating threshold.
The 5SV3612-6 is the corresponding 25 A, 2-pole / 1+N, Type A, 300 mA device.
Therefore:
5SV3312-6RC → 25 A, 30 mA
5SV3412-6 → 25 A, 100 mA
5SV3612-6 → 25 A, 300 mA
The correct residual-current sensitivity should be selected according to the complete electrical protection scheme.
The 5SV3342-6RC is a 25 A, 4-pole / 3+N, Type A, 30 mA RCCB, while the 5SV3312-6RC is a 25 A, 2-pole / 1+N device.
Therefore:
5SV3312-6RC → 25 A, 2-pole / 1+N, Type A, 30 mA
5SV3342-6RC → 25 A, 4-pole / 3+N, Type A, 30 mA
The first is intended for suitable single-phase systems and the second for suitable three-phase-plus-neutral systems.
The Siemens 5SV3312-6RC is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
Commercial electrical contractors
Facility-maintenance teams
OEMs
Machine builders
Electrical distributors
Industrial maintenance departments
Electrical product dealers
For SB Smart, the product is positioned as a Siemens SENTRON 5SV3 Type A RCCB for 25 A single-phase residual-current protection.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON 5SV3 |
| Article Number | 5SV3312-6RC |
| Product Type | Residual Current Operated Circuit Breaker (RCCB) |
| RCCB Type | Type A |
| Rated Current | 25 A |
| Number of Poles | 2 Pole / 1+N |
| Residual Operating Current | 30 mA |
| Operation | Instantaneous |
| Rated Operating Voltage | 230 V AC for corresponding Siemens article |
| India Market Description | 240 V, 2MW |
| Module Width | 2 Modules / approx. 36 mm |
| DIN Size | Size 1 according to DIN 43880 |
| Grid Spacing | 60 mm |
| Short-Circuit Current Rating | 10 kA |
| Maximum Series Fuse | 63 A |
| Rated Insulation Voltage | 2,000 V |
| Protection Degree | IP20 when installed in a suitable distribution board |
| Switching Capacity | 0.5 kA according to IEC 61008-1 |
| Power Loss per Pole | 1 W at rated current |
| Mechanical Service Life | 10,000 operating cycles typical |
| Operating Frequency | 50 Hz |
These specifications are based on Siemens' current technical data for 5SV3312-6.
Siemens SENTRON 5SV3 RCCB
Article number 5SV3312-6RC
25 A rated current
2-pole / 1+N configuration
30 mA residual-current sensitivity
Type A
Instantaneous operation
230 V AC technical rating for the corresponding Siemens article
240 V India-market designation
2-module modular format
10 kA short-circuit current rating
2,000 V rated insulation voltage
60 mm grid spacing
DIN modular installation
Suitable for single-phase residual-current protection
Suitable for installations with compatible electronic loads
Type A protection: Suitable where residual currents may include pulsating DC components.
25 A rating: Suitable for compatible single-phase circuits and feeders.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
2-pole / 1+N design: Suitable for phase-and-neutral single-phase systems.
Instantaneous operation: Provides residual-current disconnection without intentional short-time delay.
Compact 2-module format: Helps optimize space in modular distribution boards.
DIN modular installation: Supports convenient integration into standard electrical protection assemblies.
10 kA short-circuit rating: Supports coordination with suitable upstream protective equipment.
SENTRON 5SV3 platform: Provides a standardized Siemens Type A residual-current protection solution.
The Siemens 5SV3312-6RC is a 25 A, 2-pole / 1+N, Type A RCCB with 30 mA residual-current sensitivity, designed for suitable single-phase AC electrical installations. Siemens' current Industry Mall identifies the corresponding 5SV3312-6 as an active 2-pole Type A RCCB with 25 A rated current, 30 mA residual current and 230 V AC rated voltage.
Its Type A characteristic makes it particularly suitable for compatible installations where residual currents can contain pulsating DC components.
For SB Smart, this product is best presented as a Siemens SENTRON 5SV3 Type A residual-current circuit breaker for 25 A single-phase electrical protection across India.
SB Smart supplies Siemens SENTRON/Betagard RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SV3312-6RC is a Siemens SENTRON 5SV3 residual-current operated circuit breaker rated at 25 A, with 2 poles / 1+N, 30 mA residual-current sensitivity and Type A characteristics.
It has 2 poles, configured for 1+N single-phase applications.
The rated current is 25 A.
The rated residual operating current is 30 mA.
It is a Type A RCCB, suitable for compatible AC residual currents and pulsating DC residual-current components.
Yes. Siemens identifies the corresponding 5SV3312-6 as an instantaneous RCCB.
Siemens' current technical data specifies 230 V AC for the corresponding 5SV3312-6 article, while the supplied India description uses 240 V.
2MW means 2 module width in the modular installation format. It does not mean a 2 MW power rating.
The specified short-circuit current rating is 10 kA, with a maximum permissible 63 A series fuse for the corresponding article.
5SV3312-6RC: 25 A, 2-pole / 1+N, Type A, 30 mA.
5SV4312-0RC: 25 A, 2-pole / 1+N, Type AC, 30 mA.
5SV3312-6RC: 25 A, Type A, 30 mA.
5SV3412-6: 25 A, Type A, 100 mA.
SB Smart supplies Siemens SENTRON 5SV3 Type A RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, maintenance teams and distribution applications.
|
Parameter |
Specification |
|
Product
Series |
Siemens
Betagard / SENTRON 5SV3 |
|
Part
Number |
5SV3312-6RC |
|
Product
Type |
RCCB
(Residual Current Circuit Breaker) |
|
Type |
Type
A |
|
Rated
Current |
25
A |
|
Sensitivity |
30
mA |
|
Poles |
2
Pole |
|
Rated
Voltage |
230
V AC |
|
Frequency |
50/60
Hz |
|
Mounting
Type |
DIN
Rail |
|
Protection |
Earth
leakage (residual current) |
|
Breaking
Capacity |
10
kA (typical series rating) |
|
Standard |
IEC
61008-1 |
|
Application |
Residential,
Commercial, Industrial protection |
No reviews yet.