RES.CUR.OP.CIRCUIT BREAKER TYPE A 25A 3+N-POLE 30MA 415V 4MW INDIA - 5SV3342-6RC

(0 Reviews)
Best Price (Excl. GST):
12,465 / nos MRP: ₹12,465 / nos
GST (18%): 2,244
Total Price (Incl. GST): ₹14,709
Available as per OEM Lead Time
Quantity:
nos
Secure
Fast Delivery
24/7 Support

100% Genuine Product

Industrial Grade

Quality Tested

GST Invoice Available

Product Description

Siemens 5SV3342-6RC RCCB – 25A, 4-Pole, 30mA, Type A, 415V

The Siemens 5SV3342-6RC is a SENTRON 5SV3 Residual Current Operated Circuit Breaker (RCCB) designed for residual-current protection in suitable three-phase AC electrical installations with neutral. It is a 4-pole / 3+N, Type A RCCB with a 25 A rated current and 30 mA rated residual operating current. Siemens' current product data identifies the corresponding 5SV3342-6 as an instantaneous 4-pole Type A RCCB, rated 25 A, 30 mA and 400 V AC.

The supplied India product designation specifies 415 V and 4MW, making the device suitable for compatible three-phase-plus-neutral distribution boards, electrical panels and residual-current protection applications.

Siemens 5SV3342-6RC Residual Current Circuit Breaker

The 5SV3342-6RC belongs to the Siemens SENTRON 5SV3 RCCB family. Its primary function is to monitor residual current and disconnect the protected circuit when the residual current reaches the specified operating threshold.

The 4-pole / 3+N configuration is designed for three-phase systems with neutral, making it suitable for compatible industrial, commercial and building electrical installations.

Siemens lists the corresponding 5SV3342-6 as an active product with a description of 4-pole, Type A, 25 A, 30 mA, 400 V AC.

25 A Rated Current

The RCCB has a rated current of 25 A.

This makes it suitable for compatible three-phase circuits and feeders where a 25 A residual-current protection device is required.

The protected circuit should always be designed so that the RCCB operates within its specified electrical ratings and installation conditions.

30 mA Residual Current Sensitivity

The 5SV3342-6RC has a rated residual operating current of 30 mA. Siemens' current data sheet confirms 30 mA as the rated tripping fault current.

When residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.

The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable installation requirements.

Type A Residual Current Protection

The device is a Type A RCCB.

Type A residual-current protection is designed to detect suitable AC residual currents as well as pulsating DC residual-current components. This makes Type A RCCBs suitable for many modern installations containing electronic and rectifier-based loads.

Potential applications can include:

  • Electronic power supplies

  • Rectifier circuits

  • Automation equipment

  • Variable-speed equipment

  • Industrial electronic machinery

  • Modern commercial equipment

The appropriate RCCB type should always be selected according to the residual-current characteristics of the connected equipment.

4-Pole / 3+N Configuration

The 5SV3342-6RC has 4 poles, making it suitable for three-phase plus neutral circuits.

This arrangement allows the three phases and neutral to be incorporated into the residual-current protection system.

Typical applications include:

  • Three-phase distribution boards

  • PCC panels

  • MCC panels

  • Industrial feeders

  • Commercial electrical panels

  • Sub-distribution boards

  • Machine supply circuits

  • Factory electrical systems

415 V India Application

The supplied India designation identifies the RCCB for 415 V AC applications.

Siemens' current technical data for the corresponding 5SV3342-6 specifies 400 V AC rated operating voltage.

For the SB Smart product listing, the 415 V India-market designation can be retained while actual installation selection should be checked against the Siemens technical rating and the electrical system design.

Instantaneous Operation

The 5SV3342-6RC is an instantaneous RCCB. Siemens specifies that the switching function is not short-time delayed.

This means the device responds without an intentionally introduced short-time delay when the residual-current threshold is reached.

10 kA Short-Circuit Current Rating

The corresponding Siemens 5SV3342-6 is specified with a 10 kA short-circuit current rating. The data sheet also specifies a maximum permissible 80 A series fuse for short-circuit coordination.

The RCCB should nevertheless be coordinated with suitable upstream overcurrent protection and the prospective short-circuit conditions of the installation.

An RCCB primarily provides residual-current protection and should not be treated as a substitute for an MCB or MCCB for overload and short-circuit protection unless the complete protection arrangement specifically provides those functions.

4-Module Design

The India product description specifies 4MW, meaning 4 module width.

The 4MW designation refers to the physical modular width of the device and does not mean a 4 MW power rating.

The Siemens 2025 product catalogue identifies the Type A 3P+N range in a 4-module arrangement, including the 25 A article 5SV3342-6.

DIN Modular Installation

The corresponding 5SV3342-6 is classified as a size 1 installation device according to DIN 43880 and has 60 mm grid spacing.

This supports installation in conventional modular distribution boards and electrical panels.

The RCCB can be combined with compatible MCBs, busbars and supplementary protection accessories according to the panel design.

IP20 Protection

Siemens specifies IP20 protection when the device is installed in a suitable distribution board with connected conductors.

The RCCB should therefore be installed inside an appropriate electrical enclosure or distribution assembly.

Residual Current Protection

Residual current occurs when part of the electrical current flows outside the intended circuit path, such as through an unintended leakage path to earth.

The RCCB monitors the current balance and disconnects the protected circuit when the residual current reaches the configured 30 mA threshold.

This provides an additional layer of residual-current protection within the overall electrical safety system.

Applications with Electronic Loads

The Type A characteristic makes the 5SV3342-6RC suitable for installations where residual currents may contain pulsating DC components.

Potential applications include:

  • Industrial automation equipment

  • Electronic control panels

  • Rectifier-based machinery

  • Variable-speed equipment

  • Commercial electronic equipment

  • Modern machine installations

  • Power-electronic loads

The actual suitability should be verified against the residual-current characteristics of the connected equipment.

Three-Phase Distribution Applications

The 5SV3342-6RC can be considered for compatible:

  • Industrial distribution boards

  • Commercial electrical panels

  • Three-phase feeder circuits

  • PCC and MCC panels

  • Factory electrical systems

  • Building distribution systems

  • Machine supply circuits

  • Sub-distribution boards

Industrial Panel Applications

The combination of:

25 A + 30 mA + Type A + 4-pole / 3+N

makes this article suitable for selected three-phase residual-current protection applications.

Panel builders can use it where the protection design requires a Type A RCCB with a 25 A rated current and 30 mA residual-current threshold.

Protection Coordination

The RCCB should be coordinated with appropriate upstream overcurrent protection where required.

A typical arrangement can include:

Incoming Supply → MCB/MCCB → RCCB → Protected Load

The exact arrangement depends on the electrical system, upstream protective device and applicable installation requirements.

The RCCB's residual-current function should be considered separately from overload and short-circuit protection.

Maintenance and Testing

RCCBs should be included in the electrical installation's regular inspection and testing program.

The test function should be operated according to the manufacturer's instructions and applicable maintenance requirements to verify correct residual-current tripping.

Regular testing helps confirm that the protective mechanism remains operational.

Installation Considerations

Before selecting the 5SV3342-6RC, verify:

  • Rated current: 25 A

  • Residual-current sensitivity: 30 mA

  • RCCB type: Type A

  • Pole configuration: 4-pole / 3+N

  • System voltage compatibility

  • Upstream overcurrent protection

  • Available panel space: 4 module width

  • Conductor size and termination

  • Connected equipment leakage-current characteristics

  • Applicable national electrical regulations

The RCCB type should be selected according to the actual load and residual-current waveform.

Difference from Type AC 25 A, 30 mA Version

The 5SV4342-0RC is a 25 A, 4-pole, Type AC, 30 mA RCCB, whereas the 5SV3342-6RC is a 25 A, 4-pole, Type A, 30 mA RCCB.

Therefore:

5SV3342-6RC → Type A, 25 A, 30 mA

5SV4342-0RC → Type AC, 25 A, 30 mA

The main difference is the residual-current type.

Difference from Type A 40 A Version

The 5SV3344-6RC is the corresponding 40 A, 4-pole, Type A, 30 mA version.

Therefore:

5SV3342-6RC → 25 A

5SV3344-6RC → 40 A

Both are Type A, 4-pole RCCBs with 30 mA residual-current sensitivity. Siemens' 2025 catalogue lists both articles together in this range.

Difference from Type A 63 A Version

The 5SV3346-6RC is the corresponding 63 A, 4-pole, Type A, 30 mA version.

Therefore:

5SV3342-6RC → 25 A

5SV3344-6RC → 40 A

5SV3346-6RC → 63 A

The correct rated current should be selected according to the protected circuit.

Difference from Type A 80 A Version

The 5SV3347-6 is the corresponding 80 A, 4-pole, Type A, 30 mA device in the Siemens product range.

Therefore:

5SV3342-6RC → 25 A

5SV3344-6RC → 40 A

5SV3346-6RC → 63 A

5SV3347-6 → 80 A

Difference from Type A 100 mA Version

The 5SV3442-6 is a 25 A, 4-pole, Type A, 100 mA RCCB in the Siemens 5SV3 range. Siemens' 2025 catalogue lists this article separately from the 30 mA 5SV3342-6.

Therefore:

5SV3342-6RC → 25 A, 30 mA

5SV3442-6 → 25 A, 100 mA

The main difference is the residual-current operating threshold.

Difference from Type A 300 mA Version

The 5SV3642-6RC belongs to the corresponding Type A range with a 300 mA residual-current threshold.

Therefore:

5SV3342-6RC → 25 A, 30 mA

5SV3642-6RC → 25 A, 300 mA

The correct sensitivity should be selected according to the overall electrical protection scheme.

Difference from Type B Version

Type B RCCBs are intended for applications requiring detection of a broader range of residual-current waveforms.

The 5SV3342-6RC is specifically a Type A, instantaneous RCCB, so it should not be substituted by another RCCB type without checking the protection requirements of the connected equipment.

Difference from Selective Type A Version

Selective RCCBs provide intentional time grading for coordination with other residual-current protective devices.

The 5SV3342-6RC is instantaneous, so it does not provide this intentional short-time delay.

Suitable for Electrical Panel Builders and Industrial Buyers

The Siemens 5SV3342-6RC is relevant for:

  • Electrical panel builders

  • Industrial buyers

  • Electrical contractors

  • Commercial electrical contractors

  • Facility-maintenance teams

  • OEMs

  • Machine builders

  • Electrical distributors

  • Factory maintenance departments

  • Electrical product dealers

For SB Smart, the product is positioned as a Siemens SENTRON 5SV3 Type A RCCB for 25 A three-phase residual-current protection.

Technical Specification

SpecificationDetails
BrandSiemens
Product FamilySENTRON 5SV3
Article Number5SV3342-6RC
Product TypeResidual Current Operated Circuit Breaker (RCCB)
RCCB TypeType A
Rated Current25 A
Number of Poles4 Pole / 3+N
Residual Operating Current30 mA
OperationInstantaneous
Rated Operating Voltage400 V AC for corresponding Siemens article
India Market Description415 V AC, 4MW
Module Width4 Modules
DIN SizeSize 1 according to DIN 43880
Grid Spacing60 mm
Short-Circuit Current Rating10 kA
Maximum Series Fuse80 A
Rated Insulation Voltage2,000 V
Pollution Degree2
Protection DegreeIP20 when installed in a suitable distribution board
Switching Capacity per IEC 61008-10.8 kA
Typical Mechanical Service Life10,000 operating cycles
Rated Frequency50 Hz

These specifications are based on Siemens' current data sheet for 5SV3342-6.

Key Features

  • Siemens SENTRON 5SV3 RCCB

  • Article number 5SV3342-6RC

  • 25 A rated current

  • 4-pole / 3+N configuration

  • 30 mA residual-current sensitivity

  • Type A

  • Instantaneous operation

  • 400 V AC technical rating for the corresponding Siemens article

  • 415 V India-market designation

  • 4-module modular format

  • 10 kA short-circuit current rating

  • 2,000 V rated insulation voltage

  • 60 mm grid spacing

  • DIN modular installation

  • Suitable for three-phase-plus-neutral residual-current protection

  • Suitable for installations with compatible electronic loads

Benefits

  • Type A protection: Suitable where residual currents may include pulsating DC components.

  • 25 A rating: Suitable for compatible three-phase distribution and feeder circuits.

  • 30 mA sensitivity: Provides residual-current protection at the specified operating threshold.

  • 4-pole / 3+N design: Suitable for three-phase plus neutral systems.

  • Instantaneous operation: Provides residual-current disconnection without intentional short-time delay.

  • 4-module format: Supports standard modular electrical-panel installation.

  • 10 kA short-circuit rating: Supports coordination with suitable upstream protective equipment.

  • DIN modular design: Allows convenient integration into conventional electrical distribution assemblies.

  • Siemens SENTRON 5SV3 platform: Provides a standardized Type A residual-current protection solution.

Why Choose Siemens 5SV3342-6RC?

The Siemens 5SV3342-6RC is a 25 A, 4-pole / 3+N, Type A RCCB with 30 mA residual-current sensitivity, designed for suitable three-phase electrical installations. Siemens' current Industry Mall and data sheet identify the corresponding 5SV3342-6 as an active, instantaneous 4-pole Type A RCCB with 25 A rated current, 30 mA residual current and 400 V AC rated voltage.

Its Type A characteristic makes it suitable for compatible installations where residual-current waveforms can contain pulsating DC components.

For SB Smart, this product is best presented as a Siemens SENTRON 5SV3 Type A residual-current circuit breaker for 25 A three-phase electrical protection across India.

Delivery Across India

SB Smart supplies Siemens SENTRON/Betagard RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.

Major delivery locations include:

  • Faridabad

  • Delhi

  • Gurgaon/Gurugram

  • Delhi NCR

  • Noida

  • Greater Noida

  • Haryana

  • Punjab

  • Mumbai

  • Pune

  • Ahmedabad

  • Bengaluru

  • Hyderabad

  • Chennai

  • Kolkata

  • Jaipur

  • Chandigarh

  • Lucknow

  • Indore

  • Surat

  • Vadodara

  • Nagpur

  • Coimbatore

  • And other major cities across India

Frequently Asked Questions

1. What is Siemens 5SV3342-6RC?

The 5SV3342-6RC is a Siemens SENTRON 5SV3 residual-current operated circuit breaker rated at 25 A, with 4 poles / 3+N, 30 mA residual-current sensitivity and Type A characteristics.

2. How many poles does it have?

It has 4 poles, suitable for three-phase plus neutral applications.

3. What is the rated current?

The rated current is 25 A.

4. What is the residual-current sensitivity?

The rated residual operating current is 30 mA.

5. What type of RCCB is it?

It is a Type A RCCB, suitable for compatible AC residual currents and pulsating DC residual-current components.

6. Is it instantaneous?

Yes. Siemens identifies the corresponding 5SV3342-6 as instantaneous, with no short-time delayed switching function.

7. What is the voltage rating?

Siemens' current technical data specifies 400 V AC for the corresponding 5SV3342-6 article, while the India-facing designation uses 415 V.

8. What does 4MW mean?

4MW means 4 module width in the modular installation format. It does not mean a 4 MW power rating.

9. What is the short-circuit current rating?

The specified short-circuit current rating is 10 kA.

10. What is the difference between 5SV3342-6RC and 5SV4342-0RC?

5SV3342-6RC: 25 A, 4-pole, Type A, 30 mA.

5SV4342-0RC: 25 A, 4-pole, Type AC, 30 mA.

11. What is the difference between 5SV3342-6RC and 5SV3344-6RC?

5SV3342-6RC: 25 A, 4-pole, Type A, 30 mA.

5SV3344-6RC: 40 A, 4-pole, Type A, 30 mA. Siemens lists both within the same Type A 3P+N range.

12. Where can I buy Siemens 5SV3342-6RC in India?

SB Smart supplies Siemens SENTRON 5SV3 Type A RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, maintenance teams and distribution applications.

Technical Specifications

Parameter

Specification

Product Series

Siemens SENTRON 5SV3 (Betagard)

Part Number

5SV3342-6RC

Product Type

RCCB (Residual Current Circuit Breaker)

Type

Type A

Rated Current

25 A

Sensitivity

30 mA

Poles

4 Pole (3P+N)

Rated Voltage

230/400 V AC

Frequency

50/60 Hz

Mounting Type

DIN Rail

Protection

Earth leakage (residual current)

Short-Circuit Capacity

Up to 10 kA (series dependent)

Standard

IEC 61008-1

Application

Residential, Commercial & Light Industrial

Customer Reviews

Write a Review

No reviews yet.

Why Buy From SB Smart?

Authorized Supplier
Genuine products directly from manufacturers with warranty support.
Industrial Expertise
Over 10 years of experience in industrial automation and electricals.
PAN India Delivery
Fast and secure shipping to all major industrial hubs across India.
Dedicated Support
Expert technical team available for product selection and support.

Request a Quote

×
Product: Product Name

Thank You!

Your quote request has been submitted successfully.

Our team will contact you shortly.

Product Enquiry

×
Enquiring for: Product Name

Enquiry Sent!

We have received your enquiry.

Our team will get back to you soon.