The Siemens 5SV3342-6RC is a SENTRON 5SV3 Residual Current Operated Circuit Breaker (RCCB) designed for residual-current protection in suitable three-phase AC electrical installations with neutral. It is a 4-pole / 3+N, Type A RCCB with a 25 A rated current and 30 mA rated residual operating current. Siemens' current product data identifies the corresponding 5SV3342-6 as an instantaneous 4-pole Type A RCCB, rated 25 A, 30 mA and 400 V AC.
The supplied India product designation specifies 415 V and 4MW, making the device suitable for compatible three-phase-plus-neutral distribution boards, electrical panels and residual-current protection applications.
The 5SV3342-6RC belongs to the Siemens SENTRON 5SV3 RCCB family. Its primary function is to monitor residual current and disconnect the protected circuit when the residual current reaches the specified operating threshold.
The 4-pole / 3+N configuration is designed for three-phase systems with neutral, making it suitable for compatible industrial, commercial and building electrical installations.
Siemens lists the corresponding 5SV3342-6 as an active product with a description of 4-pole, Type A, 25 A, 30 mA, 400 V AC.
The RCCB has a rated current of 25 A.
This makes it suitable for compatible three-phase circuits and feeders where a 25 A residual-current protection device is required.
The protected circuit should always be designed so that the RCCB operates within its specified electrical ratings and installation conditions.
The 5SV3342-6RC has a rated residual operating current of 30 mA. Siemens' current data sheet confirms 30 mA as the rated tripping fault current.
When residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.
The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable installation requirements.
The device is a Type A RCCB.
Type A residual-current protection is designed to detect suitable AC residual currents as well as pulsating DC residual-current components. This makes Type A RCCBs suitable for many modern installations containing electronic and rectifier-based loads.
Potential applications can include:
Electronic power supplies
Rectifier circuits
Automation equipment
Variable-speed equipment
Industrial electronic machinery
Modern commercial equipment
The appropriate RCCB type should always be selected according to the residual-current characteristics of the connected equipment.
The 5SV3342-6RC has 4 poles, making it suitable for three-phase plus neutral circuits.
This arrangement allows the three phases and neutral to be incorporated into the residual-current protection system.
Typical applications include:
Three-phase distribution boards
PCC panels
MCC panels
Industrial feeders
Commercial electrical panels
Sub-distribution boards
Machine supply circuits
Factory electrical systems
The supplied India designation identifies the RCCB for 415 V AC applications.
Siemens' current technical data for the corresponding 5SV3342-6 specifies 400 V AC rated operating voltage.
For the SB Smart product listing, the 415 V India-market designation can be retained while actual installation selection should be checked against the Siemens technical rating and the electrical system design.
The 5SV3342-6RC is an instantaneous RCCB. Siemens specifies that the switching function is not short-time delayed.
This means the device responds without an intentionally introduced short-time delay when the residual-current threshold is reached.
The corresponding Siemens 5SV3342-6 is specified with a 10 kA short-circuit current rating. The data sheet also specifies a maximum permissible 80 A series fuse for short-circuit coordination.
The RCCB should nevertheless be coordinated with suitable upstream overcurrent protection and the prospective short-circuit conditions of the installation.
An RCCB primarily provides residual-current protection and should not be treated as a substitute for an MCB or MCCB for overload and short-circuit protection unless the complete protection arrangement specifically provides those functions.
The India product description specifies 4MW, meaning 4 module width.
The 4MW designation refers to the physical modular width of the device and does not mean a 4 MW power rating.
The Siemens 2025 product catalogue identifies the Type A 3P+N range in a 4-module arrangement, including the 25 A article 5SV3342-6.
The corresponding 5SV3342-6 is classified as a size 1 installation device according to DIN 43880 and has 60 mm grid spacing.
This supports installation in conventional modular distribution boards and electrical panels.
The RCCB can be combined with compatible MCBs, busbars and supplementary protection accessories according to the panel design.
Siemens specifies IP20 protection when the device is installed in a suitable distribution board with connected conductors.
The RCCB should therefore be installed inside an appropriate electrical enclosure or distribution assembly.
Residual current occurs when part of the electrical current flows outside the intended circuit path, such as through an unintended leakage path to earth.
The RCCB monitors the current balance and disconnects the protected circuit when the residual current reaches the configured 30 mA threshold.
This provides an additional layer of residual-current protection within the overall electrical safety system.
The Type A characteristic makes the 5SV3342-6RC suitable for installations where residual currents may contain pulsating DC components.
Potential applications include:
Industrial automation equipment
Electronic control panels
Rectifier-based machinery
Variable-speed equipment
Commercial electronic equipment
Modern machine installations
Power-electronic loads
The actual suitability should be verified against the residual-current characteristics of the connected equipment.
The 5SV3342-6RC can be considered for compatible:
Industrial distribution boards
Commercial electrical panels
Three-phase feeder circuits
PCC and MCC panels
Factory electrical systems
Building distribution systems
Machine supply circuits
Sub-distribution boards
The combination of:
25 A + 30 mA + Type A + 4-pole / 3+N
makes this article suitable for selected three-phase residual-current protection applications.
Panel builders can use it where the protection design requires a Type A RCCB with a 25 A rated current and 30 mA residual-current threshold.
The RCCB should be coordinated with appropriate upstream overcurrent protection where required.
A typical arrangement can include:
Incoming Supply → MCB/MCCB → RCCB → Protected Load
The exact arrangement depends on the electrical system, upstream protective device and applicable installation requirements.
The RCCB's residual-current function should be considered separately from overload and short-circuit protection.
RCCBs should be included in the electrical installation's regular inspection and testing program.
The test function should be operated according to the manufacturer's instructions and applicable maintenance requirements to verify correct residual-current tripping.
Regular testing helps confirm that the protective mechanism remains operational.
Before selecting the 5SV3342-6RC, verify:
Rated current: 25 A
Residual-current sensitivity: 30 mA
RCCB type: Type A
Pole configuration: 4-pole / 3+N
System voltage compatibility
Upstream overcurrent protection
Available panel space: 4 module width
Conductor size and termination
Connected equipment leakage-current characteristics
Applicable national electrical regulations
The RCCB type should be selected according to the actual load and residual-current waveform.
The 5SV4342-0RC is a 25 A, 4-pole, Type AC, 30 mA RCCB, whereas the 5SV3342-6RC is a 25 A, 4-pole, Type A, 30 mA RCCB.
Therefore:
5SV3342-6RC → Type A, 25 A, 30 mA
5SV4342-0RC → Type AC, 25 A, 30 mA
The main difference is the residual-current type.
The 5SV3344-6RC is the corresponding 40 A, 4-pole, Type A, 30 mA version.
Therefore:
5SV3342-6RC → 25 A
5SV3344-6RC → 40 A
Both are Type A, 4-pole RCCBs with 30 mA residual-current sensitivity. Siemens' 2025 catalogue lists both articles together in this range.
The 5SV3346-6RC is the corresponding 63 A, 4-pole, Type A, 30 mA version.
Therefore:
5SV3342-6RC → 25 A
5SV3344-6RC → 40 A
5SV3346-6RC → 63 A
The correct rated current should be selected according to the protected circuit.
The 5SV3347-6 is the corresponding 80 A, 4-pole, Type A, 30 mA device in the Siemens product range.
Therefore:
5SV3342-6RC → 25 A
5SV3344-6RC → 40 A
5SV3346-6RC → 63 A
5SV3347-6 → 80 A
The 5SV3442-6 is a 25 A, 4-pole, Type A, 100 mA RCCB in the Siemens 5SV3 range. Siemens' 2025 catalogue lists this article separately from the 30 mA 5SV3342-6.
Therefore:
5SV3342-6RC → 25 A, 30 mA
5SV3442-6 → 25 A, 100 mA
The main difference is the residual-current operating threshold.
The 5SV3642-6RC belongs to the corresponding Type A range with a 300 mA residual-current threshold.
Therefore:
5SV3342-6RC → 25 A, 30 mA
5SV3642-6RC → 25 A, 300 mA
The correct sensitivity should be selected according to the overall electrical protection scheme.
Type B RCCBs are intended for applications requiring detection of a broader range of residual-current waveforms.
The 5SV3342-6RC is specifically a Type A, instantaneous RCCB, so it should not be substituted by another RCCB type without checking the protection requirements of the connected equipment.
Selective RCCBs provide intentional time grading for coordination with other residual-current protective devices.
The 5SV3342-6RC is instantaneous, so it does not provide this intentional short-time delay.
The Siemens 5SV3342-6RC is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
Commercial electrical contractors
Facility-maintenance teams
OEMs
Machine builders
Electrical distributors
Factory maintenance departments
Electrical product dealers
For SB Smart, the product is positioned as a Siemens SENTRON 5SV3 Type A RCCB for 25 A three-phase residual-current protection.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON 5SV3 |
| Article Number | 5SV3342-6RC |
| Product Type | Residual Current Operated Circuit Breaker (RCCB) |
| RCCB Type | Type A |
| Rated Current | 25 A |
| Number of Poles | 4 Pole / 3+N |
| Residual Operating Current | 30 mA |
| Operation | Instantaneous |
| Rated Operating Voltage | 400 V AC for corresponding Siemens article |
| India Market Description | 415 V AC, 4MW |
| Module Width | 4 Modules |
| DIN Size | Size 1 according to DIN 43880 |
| Grid Spacing | 60 mm |
| Short-Circuit Current Rating | 10 kA |
| Maximum Series Fuse | 80 A |
| Rated Insulation Voltage | 2,000 V |
| Pollution Degree | 2 |
| Protection Degree | IP20 when installed in a suitable distribution board |
| Switching Capacity per IEC 61008-1 | 0.8 kA |
| Typical Mechanical Service Life | 10,000 operating cycles |
| Rated Frequency | 50 Hz |
These specifications are based on Siemens' current data sheet for 5SV3342-6.
Siemens SENTRON 5SV3 RCCB
Article number 5SV3342-6RC
25 A rated current
4-pole / 3+N configuration
30 mA residual-current sensitivity
Type A
Instantaneous operation
400 V AC technical rating for the corresponding Siemens article
415 V India-market designation
4-module modular format
10 kA short-circuit current rating
2,000 V rated insulation voltage
60 mm grid spacing
DIN modular installation
Suitable for three-phase-plus-neutral residual-current protection
Suitable for installations with compatible electronic loads
Type A protection: Suitable where residual currents may include pulsating DC components.
25 A rating: Suitable for compatible three-phase distribution and feeder circuits.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
4-pole / 3+N design: Suitable for three-phase plus neutral systems.
Instantaneous operation: Provides residual-current disconnection without intentional short-time delay.
4-module format: Supports standard modular electrical-panel installation.
10 kA short-circuit rating: Supports coordination with suitable upstream protective equipment.
DIN modular design: Allows convenient integration into conventional electrical distribution assemblies.
Siemens SENTRON 5SV3 platform: Provides a standardized Type A residual-current protection solution.
The Siemens 5SV3342-6RC is a 25 A, 4-pole / 3+N, Type A RCCB with 30 mA residual-current sensitivity, designed for suitable three-phase electrical installations. Siemens' current Industry Mall and data sheet identify the corresponding 5SV3342-6 as an active, instantaneous 4-pole Type A RCCB with 25 A rated current, 30 mA residual current and 400 V AC rated voltage.
Its Type A characteristic makes it suitable for compatible installations where residual-current waveforms can contain pulsating DC components.
For SB Smart, this product is best presented as a Siemens SENTRON 5SV3 Type A residual-current circuit breaker for 25 A three-phase electrical protection across India.
SB Smart supplies Siemens SENTRON/Betagard RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SV3342-6RC is a Siemens SENTRON 5SV3 residual-current operated circuit breaker rated at 25 A, with 4 poles / 3+N, 30 mA residual-current sensitivity and Type A characteristics.
It has 4 poles, suitable for three-phase plus neutral applications.
The rated current is 25 A.
The rated residual operating current is 30 mA.
It is a Type A RCCB, suitable for compatible AC residual currents and pulsating DC residual-current components.
Yes. Siemens identifies the corresponding 5SV3342-6 as instantaneous, with no short-time delayed switching function.
Siemens' current technical data specifies 400 V AC for the corresponding 5SV3342-6 article, while the India-facing designation uses 415 V.
4MW means 4 module width in the modular installation format. It does not mean a 4 MW power rating.
The specified short-circuit current rating is 10 kA.
5SV3342-6RC: 25 A, 4-pole, Type A, 30 mA.
5SV4342-0RC: 25 A, 4-pole, Type AC, 30 mA.
5SV3342-6RC: 25 A, 4-pole, Type A, 30 mA.
5SV3344-6RC: 40 A, 4-pole, Type A, 30 mA. Siemens lists both within the same Type A 3P+N range.
SB Smart supplies Siemens SENTRON 5SV3 Type A RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, maintenance teams and distribution applications.
|
Parameter |
Specification |
|
Product
Series |
Siemens
SENTRON 5SV3 (Betagard) |
|
Part
Number |
5SV3342-6RC |
|
Product
Type |
RCCB
(Residual Current Circuit Breaker) |
|
Type |
Type
A |
|
Rated
Current |
25
A |
|
Sensitivity |
30
mA |
|
Poles |
4
Pole (3P+N) |
|
Rated
Voltage |
230/400
V AC |
|
Frequency |
50/60
Hz |
|
Mounting
Type |
DIN
Rail |
|
Protection |
Earth
leakage (residual current) |
|
Short-Circuit
Capacity |
Up
to 10 kA (series dependent) |
|
Standard |
IEC
61008-1 |
|
Application |
Residential,
Commercial & Light Industrial |
No reviews yet.