Siemens 5SV3344-6RC RCCB – 40A, 4-Pole, 30mA, Type A, 415V

The Siemens 5SV3344-6RC is a SENTRON 5SV3 Residual Current Operated Circuit Breaker (RCCB) designed for residual-current protection in suitable three-phase AC electrical installations with neutral. It is a 4-pole / 3+N, Type A RCCB with a 40 A rated current and 30 mA rated residual operating current. Siemens identifies the corresponding 5SV3344-6 as an instantaneous 4-pole Type A RCCB, rated 40 A, 30 mA and 400 V AC.

The India-facing designation specifies 415 V and 4MW, making this model suitable for compatible three-phase-plus-neutral distribution boards, industrial panels, feeder circuits and residual-current protection applications.

Siemens 5SV3344-6RC Residual Current Circuit Breaker

The 5SV3344-6RC belongs to the Siemens SENTRON 5SV3 RCCB family. Its primary function is to detect residual current and disconnect the protected circuit when the residual-current level reaches the specified operating threshold.

The 4-pole / 3+N configuration makes it suitable for three-phase electrical systems with neutral. Siemens' current Industry Mall identifies the corresponding article as an active 5SV3 Type A RCCB, 4-pole, 40 A, 30 mA, 400 V AC.

40 A Rated Current

The RCCB has a rated current of 40 A.

This makes it suitable for compatible three-phase distribution circuits and feeders where a 40 A residual-current protection device is required.

The protected circuit should always be designed so that the RCCB operates within its specified electrical ratings and installation conditions.

30 mA Residual Current Sensitivity

The 5SV3344-6RC has a rated residual operating current of 30 mA.

When residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit. Siemens' current datasheet confirms 30 mA as the rated tripping fault current.

The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable installation requirements.

Type A Residual Current Protection

The device is a Type A RCCB.

Type A residual-current protection is designed for residual currents containing AC components and pulsating DC components. This makes Type A devices suitable for many modern electrical installations containing electronic equipment and rectifier-based loads.

Potential applications can include:

  • Electronic power supplies

  • Rectifier-based equipment

  • Variable-speed equipment

  • Automation systems

  • Industrial electronic machinery

  • Modern commercial electrical equipment

The correct RCCB type should always be selected according to the residual-current characteristics of the connected equipment.

4-Pole / 3+N Configuration

The 5SV3344-6RC has 4 poles, suitable for three-phase plus neutral circuits.

This arrangement allows the three phase conductors and neutral to be incorporated into the residual-current protection system.

Typical applications include:

  • Three-phase distribution boards

  • PCC panels

  • MCC panels

  • Industrial feeder circuits

  • Commercial electrical panels

  • Sub-distribution boards

  • Machine supply circuits

  • Factory electrical systems

415 V India Application

The supplied India product designation identifies this RCCB for 415 V AC applications.

Siemens' current technical data for the corresponding 5SV3344-6 specifies 400 V AC as the rated AC supply voltage.

For the SB Smart product page, the 415 V India-market designation can be retained, while actual installation selection should be checked against the Siemens technical rating and the electrical system design.

Instantaneous Operation

The 5SV3344-6RC is an instantaneous RCCB. Siemens specifies that the switching function is not short-time delayed.

This means the device responds without an intentionally introduced short-time delay when the specified residual-current threshold is reached.

10 kA Short-Circuit Current Rating

The corresponding Siemens 5SV3344-6 has a specified 10 kA short-circuit current rating. Siemens also specifies a maximum permissible series-fuse rating of 80 A for this article.

The RCCB should nevertheless be coordinated with suitable upstream overcurrent protection and the prospective short-circuit conditions of the installation.

An RCCB primarily provides residual-current protection and should not be treated as a substitute for an MCB or MCCB for overload and short-circuit protection unless the complete protection arrangement specifically provides those functions.

4-Module Design

The India product description specifies 4MW, meaning 4 module width.

The 4MW designation refers to the physical modular width of the device and does not mean a 4 MW power rating.

The compact modular construction is suitable for:

  • Distribution boards

  • Electrical control panels

  • PCC panels

  • Sub-distribution boards

  • Commercial switchboards

  • Industrial protection assemblies

DIN Modular Installation

The corresponding 5SV3344-6 is classified as a size 1 installation device according to DIN 43880 and uses 60 mm grid spacing.

This supports installation in conventional modular electrical distribution assemblies.

The RCCB can be combined with compatible MCBs, busbars and other protective accessories according to the panel design.

IP20 Protection

Siemens specifies IP20 protection when the device is installed in a suitable distribution board with connected conductors.

The RCCB should therefore be installed inside an appropriate electrical enclosure or distribution assembly.

Residual Current Protection

Residual current occurs when part of the electrical current flows outside the intended circuit path, such as through an unintended leakage path to earth.

The RCCB monitors the current balance and disconnects the protected circuit when the residual current reaches the configured 30 mA threshold.

This provides an additional layer of residual-current protection within the overall electrical safety system.

Applications with Electronic Loads

The Type A characteristic makes this RCCB suitable for installations where residual currents may include pulsating DC components.

Potential applications include:

  • Industrial automation equipment

  • Electronic control panels

  • Rectifier-based machinery

  • Variable-speed equipment

  • Commercial electronic equipment

  • Modern machine installations

  • Power-electronic loads

The actual suitability should be verified against the residual-current characteristics of the connected equipment.

Three-Phase Distribution Applications

The 5SV3344-6RC can be considered for compatible:

  • Industrial distribution boards

  • Commercial electrical panels

  • Three-phase feeder circuits

  • PCC and MCC panels

  • Factory electrical systems

  • Building distribution systems

  • Machine supply circuits

  • Sub-distribution boards

Industrial Panel Applications

The combination of:

40 A + 30 mA + Type A + 4-pole / 3+N

makes this article suitable for selected three-phase residual-current protection applications.

Panel builders can use it where the protection design requires a Type A RCCB with a 40 A rated current and 30 mA residual-current threshold.

Maintenance and Testing

RCCBs should be included in the electrical installation's regular inspection and testing program.

The test function should be operated according to the manufacturer's instructions and applicable electrical-maintenance requirements to verify correct residual-current tripping.

Regular testing helps confirm that the protective mechanism remains operational.

Installation Considerations

Before selecting the 5SV3344-6RC, verify:

  • Rated current: 40 A

  • Residual-current sensitivity: 30 mA

  • RCCB type: Type A

  • Pole configuration: 4-pole / 3+N

  • System voltage compatibility

  • Upstream overcurrent protection

  • Available panel space: 4 module width

  • Conductor size and termination

  • Connected equipment leakage-current characteristics

  • Applicable national electrical regulations

The RCCB type should be selected according to the actual load and residual-current waveform.

Difference from Type AC 40 A, 30 mA Version

The 5SV4344-0RC is a 40 A, 4-pole, Type AC, 30 mA RCCB, whereas the 5SV3344-6RC is a 40 A, 4-pole, Type A, 30 mA RCCB.

Therefore:

5SV3344-6RC → Type A, 40 A, 30 mA

5SV4344-0RC → Type AC, 40 A, 30 mA

The main difference is the residual-current type.

Difference from Type A 63 A Version

The 5SV3346-6RC is the corresponding 63 A, 4-pole, Type A, 30 mA version.

Therefore:

5SV3344-6RC → 40 A

5SV3346-6RC → 63 A

The main difference is the rated current.

Difference from Type A 300 mA Version

The 5SV3644-6RC belongs to the Type A family with a higher residual-current threshold.

The 5SV3344-6RC is specifically the 30 mA version, while selection of a 300 mA device depends on the required protection scheme.

Difference from Type B Version

Type B RCCBs are designed for a broader range of residual-current waveforms than Type A.

The 5SV3344-6RC is specifically a Type A, instantaneous RCCB and should not be replaced by another RCCB type without verifying the protection requirements of the connected equipment.

Difference from Selective Type A Version

A selective RCCB incorporates intentional time grading for coordination with other residual-current protective devices.

The 5SV3344-6RC is instantaneous, so it does not provide selective time delay.

Difference from 25 A Version

The 5SV3342-6RC is the corresponding Type A, 25 A, 4-pole, 30 mA variant in the same product family.

The 5SV3344-6RC is selected when the required rated current is 40 A.

Difference from 63 A Version

The 5SV3346-6RC is rated at 63 A, whereas the 5SV3344-6RC is rated at 40 A.

Both are Type A, 4-pole RCCBs with 30 mA residual-current sensitivity.

Suitable for Electrical Panel Builders and Industrial Buyers

The Siemens 5SV3344-6RC is relevant for:

  • Electrical panel builders

  • Industrial buyers

  • Electrical contractors

  • Commercial electrical contractors

  • Facility-maintenance teams

  • OEMs

  • Machine builders

  • Electrical distributors

  • Factory maintenance departments

  • Electrical product dealers

For SB Smart, the product is positioned as a Siemens SENTRON 5SV3 Type A RCCB for 40 A three-phase residual-current protection.

Technical Specification

SpecificationDetails
BrandSiemens
Product FamilySENTRON 5SV3
Article Number5SV3344-6RC
Product TypeResidual Current Operated Circuit Breaker (RCCB)
RCCB TypeType A
Rated Current40 A
Number of Poles4 Pole / 3+N
Residual Operating Current30 mA
OperationInstantaneous
Rated Operating Voltage400 V AC for corresponding Siemens article
India Market Description415 V AC, 4MW
Module Width4 Modules
DIN SizeSize 1 according to DIN 43880
Grid Spacing60 mm
Short-Circuit Current Rating10 kA
Maximum Series Fuse80 A
Rated Insulation Voltage2,000 V
Protection DegreeIP20 when installed in a suitable distribution board
Operating Frequency50 Hz
Mechanical Service Life10,000 operating cycles typical

These values are based on Siemens' current data for 5SV3344-6.

Key Features

  • Siemens SENTRON 5SV3 RCCB

  • Article number 5SV3344-6RC

  • 40 A rated current

  • 4-pole / 3+N configuration

  • 30 mA residual-current sensitivity

  • Type A

  • Instantaneous operation

  • 400 V AC technical rating for the corresponding Siemens article

  • 415 V India-market designation

  • 4-module modular format

  • 10 kA short-circuit current rating

  • 2,000 V rated insulation voltage

  • 60 mm grid spacing

  • DIN modular installation

  • Suitable for three-phase-plus-neutral residual-current protection

  • Suitable for installations with compatible electronic loads

Benefits

  • Type A protection: Suitable where residual currents may include pulsating DC components.

  • 40 A rating: Suitable for compatible three-phase distribution and feeder circuits.

  • 30 mA sensitivity: Provides residual-current protection at the specified operating threshold.

  • 4-pole / 3+N design: Suitable for three-phase plus neutral systems.

  • Instantaneous operation: Provides residual-current disconnection without intentional short-time delay.

  • 4-module format: Supports standard modular electrical-panel installation.

  • 10 kA short-circuit rating: Supports coordination with suitable upstream protective equipment.

  • DIN modular design: Allows integration into conventional electrical distribution assemblies.

  • Siemens SENTRON 5SV3 platform: Provides a standardized Type A residual-current protection solution.

Why Choose Siemens 5SV3344-6RC?

The Siemens 5SV3344-6RC is a 40 A, 4-pole / 3+N, Type A RCCB with 30 mA residual-current sensitivity, designed for suitable three-phase electrical installations. Siemens' current Industry Mall identifies the corresponding 5SV3344-6 as an active 4-pole Type A RCCB, 40 A, 30 mA, 400 V AC, while its datasheet confirms instantaneous operation and a 10 kA short-circuit current rating.

Its Type A characteristic makes it particularly suitable for compatible installations where residual currents can contain pulsating DC components.

For SB Smart, this product is best presented as a Siemens SENTRON 5SV3 Type A residual-current circuit breaker for 40 A three-phase electrical protection across India.

Delivery Across India

SB Smart supplies Siemens SENTRON/Betagard RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.

Major delivery locations include:

  • Faridabad

  • Delhi

  • Gurgaon/Gurugram

  • Delhi NCR

  • Noida

  • Greater Noida

  • Haryana

  • Punjab

  • Mumbai

  • Pune

  • Ahmedabad

  • Bengaluru

  • Hyderabad

  • Chennai

  • Kolkata

  • Jaipur

  • Chandigarh

  • Lucknow

  • Indore

  • Surat

  • Vadodara

  • Nagpur

  • Coimbatore

  • And other major cities across India

Frequently Asked Questions

1. What is Siemens 5SV3344-6RC?

The 5SV3344-6RC is a Siemens SENTRON 5SV3 residual-current operated circuit breaker rated at 40 A, with 4 poles / 3+N, 30 mA residual-current sensitivity and Type A characteristics.

2. How many poles does it have?

It has 4 poles, suitable for three-phase plus neutral applications.

3. What is the rated current?

The rated current is 40 A.

4. What is the residual-current sensitivity?

The rated residual operating current is 30 mA.

5. What type of RCCB is it?

It is a Type A RCCB, suitable for compatible AC residual currents and pulsating DC residual-current components.

6. Is it instantaneous?

Yes. Siemens identifies the corresponding 5SV3344-6 as instantaneous, without short-time delayed switching.

7. What is the voltage rating?

Siemens' current technical data specifies 400 V AC for the corresponding 5SV3344-6 article, while the India-facing designation uses 415 V.

8. What does 4MW mean?

4MW means 4 module width in the modular installation format. It does not mean a 4 MW power rating.

9. What is the short-circuit current rating?

The specified short-circuit current rating is 10 kA.

10. What is the difference between 5SV3344-6RC and 5SV4344-0RC?

5SV3344-6RC: 40 A, 4-pole, Type A, 30 mA.

5SV4344-0RC: 40 A, 4-pole, Type AC, 30 mA.

11. What is the difference between 5SV3344-6RC and 5SV3346-6RC?

5SV3344-6RC: 40 A, 4-pole, Type A, 30 mA.

5SV3346-6RC: 63 A, 4-pole, Type A, 30 mA.

12. Where can I buy Siemens 5SV3344-6RC in India?

SB Smart supplies Siemens SENTRON 5SV3 Type A RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, maintenance teams and distribution applications.

Technical Specifications

ParameterSpecification
Product SeriesSiemens SENTRON 5SV3
Part Number5SV3344-6RC
Product TypeRCCB (Residual Current Circuit Breaker)
Number of Poles4 Pole (3P+N)
Rated Current (In)40A
Residual Current Sensitivity (IΔn)30mA
Tripping CharacteristicType A
Rated Operational Voltage400V AC
Frequency50 Hz
Mounting TypeDIN Rail Mounting
Short Circuit Withstand Capacity10kA
Rated Insulation Voltage (Ui)2000V
Rated Impulse Withstand Voltage (Uimp)6kV
Degree of ProtectionIP20
Ambient Operating Temperature-25°C to +45°C
Connection TypeScrew Terminal
Width4 Modular Units
Mechanical LifeApprox. 10,000 Switching Cycles
ApplicationPersonnel Protection, Earth Leakage Protection, Distribution Boards, Industrial Panels

Customer Reviews

Write a Review

No reviews yet.

Why Buy From SB Smart?

Authorized Supplier
Genuine products directly from manufacturers with warranty support.
Industrial Expertise
Over 10 years of experience in industrial automation and electricals.
PAN India Delivery
Fast and secure shipping to all major industrial hubs across India.
Dedicated Support
Expert technical team available for product selection and support.

Request a Quote

×
Product: Product Name

Thank You!

Your quote request has been submitted successfully.

Our team will contact you shortly.

Product Enquiry

×
Enquiring for: Product Name

Enquiry Sent!

We have received your enquiry.

Our team will get back to you soon.