RES.CUR.OP.CIRCUIT BREAKER TYPE A 63A 3+N-POLE 300MA 415V 4MW INDIA - 5SV3646-6RC

(0 Reviews)
Best Price (Excl. GST):
15,625 / nos MRP: ₹15,625 / nos
GST (18%): 2,813
Total Price (Incl. GST): ₹18,438
Available as per OEM Lead Time
Quantity:
nos
Secure
Fast Delivery
24/7 Support

100% Genuine Product

Industrial Grade

Quality Tested

GST Invoice Available

Product Description


Siemens 5SV3646-6RC RCCB – 63A, 4-Pole, 300mA, Type A, 415V

The Siemens 5SV3646-6RC is a SENTRON 5SV3 residual current operated circuit breaker (RCCB) designed for protection against residual currents in suitable three-phase AC electrical installations. It is a 4-pole / 3+N, Type A RCCB with a 63 A rated current and 300 mA rated residual operating current. Siemens technical documentation identifies the corresponding 5SV3646-6 as a 4-pole Type A RCCB, 63 A, 300 mA, 400 V AC, with instantaneous operation.

The supplied India product designation specifies 415 V and 4MW, making this model suitable for compatible three-phase-plus-neutral distribution and protection applications.

Siemens 5SV3646-6RC Residual Current Circuit Breaker

The 5SV3646-6RC belongs to the Siemens SENTRON 5SV3 RCCB family. Its primary purpose is to detect residual current and disconnect the protected circuit when the residual-current level reaches the specified operating threshold.

The 4-pole / 3+N configuration allows the device to be used on three-phase systems with neutral and makes it suitable for industrial, commercial and electrical-distribution applications.

Siemens also shows 5SV3646-6 as the successor to the discontinued 5SM3646-6 article, confirming the product family transition.

63 A Rated Current

The RCCB has a rated current of 63 A.

This makes it suitable for compatible three-phase distribution circuits and feeders where a 63 A residual-current protection device is required.

The protected circuit should be designed so that the RCCB remains within its specified electrical ratings and installation conditions.

300 mA Residual Current Sensitivity

The 5SV3646-6RC has a rated residual operating current of 300 mA.

When the residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.

A 300 mA residual-current threshold is commonly considered for selected distribution and equipment protection schemes. The appropriate sensitivity must be selected according to the complete electrical protection design and applicable standards.

Type A Residual Current Protection

The device is a Type A RCCB.

Unlike Type AC devices, Type A RCCBs are intended for residual currents that may include pulsating DC components in addition to AC residual current. This makes Type A protection relevant for installations containing suitable electronic and rectifier-based loads.

The correct RCCB type should always be selected according to the residual-current characteristics of the equipment and installation.

4-Pole / 3+N Configuration

The 5SV3646-6RC has 4 poles, making it suitable for three-phase plus neutral electrical systems.

This arrangement allows the three phases and neutral to be incorporated into the residual-current protection system.

Typical applications include:

  • Three-phase distribution boards

  • Industrial feeders

  • PCC panels

  • MCC panels

  • Commercial electrical panels

  • Sub-distribution boards

  • Machine supply circuits

  • Factory electrical systems

415 V AC / 400 V AC Application

The supplied India product description identifies the device for 415 V AC systems.

Siemens' technical documentation for the corresponding 5SV3646-6 specifies 400 V AC rated operating voltage.

For the SB Smart product page, the 415 V India-market designation can be retained, while actual installation selection should be based on the applicable Siemens rating and the electrical system design.

Instantaneous Operation

The 5SV3646-6RC is an instantaneous RCCB. Siemens' available product documentation identifies the device as instantaneous rather than short-time delayed.

This means the RCCB responds without an intentionally introduced short-time delay when the specified residual-current threshold is reached.

10 kA Short-Circuit Current Rating

Siemens specifies a 10 kA short-circuit current rating for the corresponding 5SV3646-6 article.

The RCCB should still be coordinated with appropriate upstream overcurrent protection and the prospective short-circuit current of the installation.

An RCCB primarily provides residual-current protection and should not be treated as a substitute for an MCB or MCCB for overload and short-circuit protection unless the complete protection arrangement specifically provides those functions.

4-Module Design

The India product description specifies 4MW, meaning 4 module width.

The 4MW designation refers to the physical modular width and does not mean a 4 MW power rating.

The compact modular format is suitable for:

  • Distribution boards

  • Electrical control panels

  • PCC panels

  • Sub-distribution boards

  • Commercial switchboards

  • Industrial protection assemblies

DIN Modular Installation

The 5SV3646-6RC is designed for modular installation in suitable electrical distribution assemblies.

Siemens specifies size 1 according to DIN 43880 for the corresponding article and a 60 mm grid spacing.

This supports integration into conventional modular protection arrangements.

IP20 Protection

Siemens specifies IP20 protection when installed in a suitable distribution board with connected conductors.

The RCCB should therefore be installed inside an appropriate electrical enclosure or distribution assembly.

Residual Current Protection

Residual current occurs when part of the electrical current flows outside its intended path, such as through an unintended leakage path to earth.

The RCCB monitors the current balance and disconnects the protected circuit when the residual current reaches the configured 300 mA threshold.

This provides an additional layer of residual-current protection within the overall electrical protection system.

Three-Phase Distribution Applications

The 5SV3646-6RC can be considered for compatible:

  • Industrial distribution boards

  • Commercial electrical panels

  • Three-phase feeder circuits

  • PCC and MCC panels

  • Factory electrical systems

  • Building distribution systems

  • Machine supply circuits

  • Sub-distribution boards

Industrial Panel Applications

The combination of:

63 A + 300 mA + Type A + 4-pole / 3+N

makes the device relevant for selected three-phase residual-current protection applications where Type A characteristics are required.

This is particularly relevant when connected equipment can produce residual-current waveforms containing pulsating DC components.

Electronic Load Compatibility

Type A RCCBs are suitable for many installations containing modern electronic equipment where residual currents may not be purely sinusoidal.

Potential applications can include systems containing:

  • Electronic power supplies

  • Rectifier circuits

  • Variable-speed equipment

  • Automation systems

  • Modern industrial control equipment

The exact suitability must be evaluated against the residual-current waveform produced by the connected equipment.

Maintenance and Testing

RCCBs should be included in an appropriate electrical inspection and testing program.

The test function should be operated according to the manufacturer's instructions and applicable maintenance requirements to verify correct residual-current tripping.

Regular testing helps confirm that the protective mechanism remains operational.

Installation Considerations

Before selecting the 5SV3646-6RC, verify:

  • Rated current: 63 A

  • Residual-current sensitivity: 300 mA

  • RCCB type: Type A

  • Pole configuration: 4-pole / 3+N

  • System voltage compatibility

  • Upstream overcurrent protection

  • Available panel space: 4 module width

  • Conductor size and termination

  • Connected equipment leakage-current characteristics

  • Applicable national electrical regulations

The RCCB type should be selected according to the actual equipment and installation design.

Difference from Type AC 300 mA Version

The Siemens 5SV4646-0RC is a 63 A, 4-pole, Type AC, 300 mA RCCB, while 5SV3646-6RC is a 63 A, 4-pole, Type A, 300 mA device.

Therefore:

5SV3646-6RC → Type A, 63 A, 300 mA

5SV4646-0RC → Type AC, 63 A, 300 mA

The main difference is the residual-current type.

Difference from Type B Version

Siemens also lists 5SV3646-4 as a 63 A, 4-pole, Type B, 300 mA, short-time-delayed RCCB for demanding residual-current applications.

Therefore:

5SV3646-6RC → Type A, instantaneous

5SV3646-4 → Type B, short-time delayed

The correct type must be selected according to the residual-current waveform and protection-coordination requirements.

Difference from Selective Type A Version

Siemens lists 5SV3646-8KL as a 63 A, 4-pole, Type A, selective, 300 mA RCCB.

Therefore:

5SV3646-6RC → Type A, instantaneous

5SV3646-8KL → Type A, selective

Selective RCCBs are used where coordination with upstream residual-current protection requires intentional time grading.

Difference from 30 mA Version

The 5SV3 Type A family contains different residual-current sensitivities.

The 5SV3646-6RC is specifically the 300 mA version, so it should not be substituted with a 30 mA device unless the protection design calls for that lower threshold.

Difference from 100 mA Version

The 5SV3646-6RC is the 300 mA version. Other Type A devices in the Siemens 5SV3 family may have different residual operating-current values.

The article number should always be checked carefully when selecting a replacement because the residual-current sensitivity directly affects the protection function.

Difference from 30 mA / 63 A Type AC Version

A Type AC 63 A RCCB with a lower residual-current sensitivity is a different product selection.

The 5SV3646-6RC should be selected where both Type A characteristics and 300 mA sensitivity are required.

Suitable for Electrical Panel Builders and Industrial Buyers

The Siemens 5SV3646-6RC is relevant for:

  • Electrical panel builders

  • Industrial buyers

  • Electrical contractors

  • Commercial electrical contractors

  • Facility-maintenance teams

  • OEMs

  • Machine builders

  • Electrical distributors

  • Factory maintenance departments

  • Electrical product dealers

For SB Smart, the product is positioned as a Siemens SENTRON 5SV3 Type A RCCB for 63 A three-phase residual-current protection.

Technical Specification

SpecificationDetails
BrandSiemens
Product FamilySENTRON 5SV3
Article Number5SV3646-6RC
Product TypeResidual Current Operated Circuit Breaker (RCCB)
RCCB TypeType A
Rated Current63 A
Number of Poles4 Pole / 3+N
Residual Operating Current300 mA
OperationInstantaneous
Rated Operating Voltage400 V AC for corresponding Siemens article
India Market Description415 V AC, 4MW
Module Width4 Modules
DIN SizeSize 1 according to DIN 43880
Grid Spacing60 mm
Short-Circuit Current Rating10 kA
Rated Insulation Voltage2,000 V
Protection DegreeIP20 when installed in suitable distribution-board conditions
Operating Frequency50/60 Hz

The specifications above are based on Siemens documentation for 5SV3646-6 and the supplied India product designation.

Key Features

  • Siemens SENTRON 5SV3 RCCB

  • Article number 5SV3646-6RC

  • 63 A rated current

  • 4-pole / 3+N configuration

  • 300 mA residual-current sensitivity

  • Type A

  • Instantaneous operation

  • 400 V AC technical rating for the corresponding Siemens article

  • 415 V India-market designation

  • 4-module modular format

  • 10 kA short-circuit current rating

  • 2,000 V rated insulation voltage

  • 60 mm grid spacing

  • DIN modular installation

  • Suitable for three-phase-plus-neutral residual-current protection

Benefits

  • Type A protection: Suitable for compatible installations where residual currents can include pulsating DC components.

  • 63 A rating: Suitable for compatible higher-current three-phase circuits.

  • 300 mA sensitivity: Provides residual-current protection at the specified operating threshold.

  • 4-pole / 3+N design: Suitable for three-phase plus neutral systems.

  • Instantaneous operation: Provides residual-current disconnection without intentional short-time delay.

  • 4-module format: Supports standard modular panel installation.

  • 10 kA short-circuit rating: Supports coordination with suitable upstream protective equipment.

  • SENTRON 5SV3 design: Provides a Siemens solution for advanced residual-current protection.

  • Industrial compatibility: Suitable for selected applications involving modern electronic loads.

Why Choose Siemens 5SV3646-6RC?

The Siemens 5SV3646-6RC is a 63 A, 4-pole / 3+N, Type A RCCB with 300 mA residual-current sensitivity, designed for suitable three-phase electrical installations. Siemens documentation identifies the corresponding 5SV3646-6 as a 4-pole Type A, 63 A, 300 mA, 400 V AC instantaneous RCCB with a 10 kA short-circuit current rating.

It is especially relevant where the electrical installation includes equipment that may generate residual currents with pulsating DC components and therefore requires Type A rather than Type AC characteristics.

For SB Smart, this product is best presented as a Siemens SENTRON 5SV3 Type A residual-current circuit breaker for 63 A three-phase electrical protection across India.

Delivery Across India

SB Smart supplies Siemens SENTRON/Betagard RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.

Major delivery locations include:

  • Faridabad

  • Delhi

  • Gurgaon/Gurugram

  • Delhi NCR

  • Noida

  • Greater Noida

  • Haryana

  • Punjab

  • Mumbai

  • Pune

  • Ahmedabad

  • Bengaluru

  • Hyderabad

  • Chennai

  • Kolkata

  • Jaipur

  • Chandigarh

  • Lucknow

  • Indore

  • Surat

  • Vadodara

  • Nagpur

  • Coimbatore

  • And other major cities across India

Frequently Asked Questions

1. What is Siemens 5SV3646-6RC?

The 5SV3646-6RC is a Siemens SENTRON 5SV3 residual-current operated circuit breaker rated at 63 A, with 4 poles / 3+N, 300 mA residual-current sensitivity and Type A characteristics.

2. How many poles does it have?

It has 4 poles, suitable for three-phase plus neutral applications.

3. What is the rated current?

The rated current is 63 A.

4. What is the residual-current sensitivity?

The rated residual operating current is 300 mA.

5. What type of RCCB is it?

It is a Type A RCCB, suitable for compatible AC residual currents and pulsating DC residual-current components.

6. Is it instantaneous?

Yes. Siemens identifies the corresponding 5SV3646-6 as instantaneous.

7. What is the voltage rating?

Siemens' technical data for the corresponding 5SV3646-6 specifies 400 V AC, while the India-facing product description uses 415 V.

8. What does 4MW mean?

4MW means 4 module width in the modular installation format. It does not mean a 4 MW power rating.

9. What is the short-circuit current rating?

The specified short-circuit current rating is 10 kA.

10. What is the difference between 5SV3646-6RC and 5SV4646-0RC?

5SV3646-6RC: 63 A, 4-pole, Type A, 300 mA.

5SV4646-0RC: 63 A, 4-pole, Type AC, 300 mA.

11. What is the difference between 5SV3646-6RC and 5SV3646-4?

5SV3646-6RC: Type A, instantaneous, 63 A, 300 mA.

5SV3646-4: Type B, short-time delayed, 63 A, 300 mA.

12. Where can I buy Siemens 5SV3646-6RC in India?

SB Smart supplies Siemens SENTRON 5SV3 Type A RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, maintenance teams and distribution applications.

Technical Specifications

ParameterSpecification
Product SeriesSiemens SENTRON 5SV3
Part Number5SV3646-6RC
Product TypeRCCB (Residual Current Circuit Breaker)
Number of Poles4 Pole (3P+N)
Rated Current (In)63A
Rated Residual Current (IΔn)300mA
Sensitivity TypeType A
Rated Voltage (Un)230/400V AC
Rated Frequency50 Hz
Mounting TypeDIN Rail
Short-Circuit Current Rating10kA
Rated Insulation Voltage (Ui)2000V
Rated Impulse Withstand Voltage (Uimp)6kV
Protection ClassIP20
Mechanical Life10,000 Operations
Operating Temperature-25°C to +45°C
Terminal Capacity0.75 mm² to 35 mm²
Tripping CharacteristicInstantaneous
Standard ComplianceIEC 61008-1
ApplicationIndustrial, Commercial & Distribution Systems

Customer Reviews

Write a Review

No reviews yet.

Why Buy From SB Smart?

Authorized Supplier
Genuine products directly from manufacturers with warranty support.
Industrial Expertise
Over 10 years of experience in industrial automation and electricals.
PAN India Delivery
Fast and secure shipping to all major industrial hubs across India.
Dedicated Support
Expert technical team available for product selection and support.

Request a Quote

×
Product: Product Name

Thank You!

Your quote request has been submitted successfully.

Our team will contact you shortly.

Product Enquiry

×
Enquiring for: Product Name

Enquiry Sent!

We have received your enquiry.

Our team will get back to you soon.