RES.CUR.OP.CIRCUIT BREAKER TYPE AC 25A 1+N-POLE 100MA 240V 2MW INDIA - 5SV4412-0RC

(0 Reviews)
Best Price (Excl. GST):
2,102 / nos MRP: ₹6,005 / nos
GST (18%): 378
Total Price (Incl. GST): ₹2,480
You Save: ₹3,903 (65%)
Ready to Dispatch
Quantity:
nos
Secure
Fast Delivery
24/7 Support

100% Genuine Product

Industrial Grade

Quality Tested

GST Invoice Available

Product Description


Siemens 5SV4412-0RC RCCB – 25A, 2-Pole, 100mA, Type AC, 240V

The Siemens 5SV4412-0RC is a SENTRON 5SV4 residual current operated circuit breaker (RCCB) designed for residual-current protection in suitable single-phase AC electrical installations. It features a 25 A rated current, 2-pole / 1+N configuration, 100 mA rated residual operating current, and Type AC residual-current protection. Siemens lists the corresponding 5SV4412-0 in the Type AC, 1P+N RCCB range for 230 V AC systems.

The India-facing description identifies this article as a 240 V, 2-module-width RCCB, making it suitable for compatible single-phase distribution boards, electrical panels and feeder circuits.

Siemens 5SV4412-0RC Residual Current Circuit Breaker

The 5SV4412-0RC belongs to the Siemens SENTRON 5SV4 / Betagard RCCB family. Its primary function is to detect residual current in a protected circuit and disconnect the circuit when the residual current reaches the specified operating threshold.

The 2-pole / 1+N arrangement is intended for single-phase circuits where phase and neutral are included in the RCCB protection arrangement. Siemens' selection data places 5SV4412-0 within the Type AC, 1P+N, 2-module RCCB range.

25 A Rated Current

The RCCB has a rated current of 25 A.

This makes it suitable for compatible single-phase distribution circuits and feeders where a 25 A residual-current protection device is required.

The protected circuit should be designed so that the RCCB operates within its specified current, voltage and environmental conditions.

100 mA Residual Current Sensitivity

The 5SV4412-0RC has a rated residual operating current of 100 mA.

When the residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.

The 100 mA sensitivity should be selected according to the intended protection function, electrical installation design and applicable regulations. Siemens' product-selection data lists 100 mA as one of the available residual-current ratings for the Type AC 1P+N range.

Type AC Residual Current Protection

The device is a Type AC RCCB.

Type AC residual-current devices are intended for compatible sinusoidal alternating residual currents. The RCCB type should always be selected according to the leakage-current waveform that can occur in the actual application.

2-Pole / 1+N Configuration

The 5SV4412-0RC has 2 poles and is designed for 1+N single-phase applications.

This arrangement allows the phase and neutral conductors to be included in the residual-current protection system.

Typical applications include:

  • Single-phase distribution boards

  • Commercial electrical panels

  • Sub-distribution circuits

  • Equipment feeders

  • Building electrical installations

  • Small industrial circuits

  • Auxiliary supply circuits

240 V AC / 230 V AC Application

The supplied India product description identifies the device as a 240 V, 2-module RCCB. Siemens' product-selection documentation identifies the corresponding 5SV4412-0 as a 230 V AC, 1P+N, Type AC RCCB.

For the SB Smart product page, the 240 V India-market designation can be retained, while the exact Siemens technical rating should be considered during product selection.

Instantaneous Operation

The 5SV4412-0RC belongs to the Siemens instantaneous Type AC 1P+N RCCB family. Siemens' catalogue distinguishes these devices from short-time delayed and selective versions.

This means the device operates without an intentionally introduced short-time delay when the specified residual-current threshold is reached.

Short-Circuit Protection and Coordination

An RCCB primarily provides residual-current protection. It should be coordinated with suitable upstream overcurrent protection where required.

The complete protection arrangement should consider:

  • Prospective short-circuit current

  • Upstream MCB/MCCB protection

  • Rated current

  • Conductor size

  • Installation requirements

The RCCB should not be treated as a replacement for an overcurrent protective device unless the complete protection scheme specifically provides that function.

Compact 2-Module Design

The India product description specifies 2MW, meaning 2 module width.

The 2MW designation refers to the physical modular width and does not mean a 2 MW power rating. Siemens identifies the corresponding Type AC 1P+N device range as a 2-module format.

This compact construction is suitable for:

  • Modular distribution boards

  • Consumer units

  • Commercial panels

  • Sub-distribution boards

  • Compact electrical enclosures

DIN Modular Installation

The 5SV4412-0RC is designed for modular installation in suitable electrical distribution assemblies.

The compact 1P+N format allows panel builders to combine the RCCB with compatible MCBs, busbars and other electrical-protection accessories.

Residual Current Protection

Residual current occurs when part of the electrical current flows through an unintended path, such as leakage to earth.

The RCCB monitors the relevant current balance and disconnects the protected circuit when the residual current reaches the configured 100 mA threshold.

This provides an additional layer of residual-current protection within the overall electrical safety design.

Single-Phase Distribution Applications

The 5SV4412-0RC can be considered for compatible single-phase applications such as:

  • Commercial distribution boards

  • Building electrical panels

  • Sub-distribution systems

  • Equipment supply circuits

  • Office electrical installations

  • Single-phase feeder protection

  • Industrial auxiliary circuits

The actual application should be determined by the electrical design and applicable local requirements.

Protection Coordination

A typical protection arrangement can include:

Incoming Supply → Overcurrent Protection → RCCB → Protected Load

The exact arrangement depends on the electrical system, upstream protective device and applicable installation requirements.

An RCCB and MCB may perform different protective functions and should be selected and coordinated accordingly.

Maintenance and Testing

RCCBs should be included in an appropriate electrical inspection and testing program.

The test function should be operated according to the manufacturer's instructions and applicable maintenance requirements to verify correct residual-current tripping.

Regular testing can help confirm that the protective mechanism remains operational.

Installation Considerations

Before selecting the 5SV4412-0RC, verify:

  • Rated current: 25 A

  • Residual-current sensitivity: 100 mA

  • RCCB type: Type AC

  • Pole arrangement: 2-pole / 1+N

  • System voltage compatibility

  • Upstream overcurrent protection

  • Available panel space: 2 module width

  • Conductor size and termination

  • Applicable national electrical regulations

Siemens' product catalogue also notes that national installation regulations must be observed and that some products may have country-specific restrictions.

Difference from 30 mA Version

The corresponding Type AC 1P+N family also includes 30 mA variants.

For example, Siemens lists 5SV4312-0 in the same 1P+N Type AC family, while 5SV4412-0 represents the 100 mA version.

Therefore:

5SV4312-0 → 25 A, 30 mA

5SV4412-0RC → 25 A, 100 mA

The residual-current sensitivity should be selected according to the intended protection scheme.

Difference from 300 mA Version

The corresponding 300 mA 25 A Type AC 1P+N variant is 5SV4612-0 in Siemens' product-selection data.

Therefore:

5SV4412-0RC → 25 A, 100 mA

5SV4612-0RC → 25 A, 300 mA

The main difference is the residual-current operating threshold.

Difference from 40 A Version

The 5SV4414-0 is the corresponding 40 A, 1P+N, Type AC, 100 mA version.

Therefore:

5SV4412-0RC → 25 A

5SV4414-0RC → 40 A

Both are part of the same general 1P+N Type AC 100 mA family.

Difference from 63 A Version

The 5SV4416-0 is the corresponding 63 A, 1P+N, Type AC, 100 mA version. Siemens lists it together with the 25 A and 40 A variants in the same product family.

Therefore:

5SV4412-0RC → 25 A

5SV4414-0RC → 40 A

5SV4416-0RC → 63 A

The appropriate rated current should be selected according to the protected circuit.

Difference from 4-Pole Version

The 5SV4442-0RC is a 25 A, 4-pole / 3+N, Type AC, 100 mA RCCB, while the 5SV4412-0RC is a 25 A, 2-pole / 1+N device.

Therefore:

5SV4412-0RC → 25 A, 2-pole / 1+N

5SV4442-0RC → 25 A, 4-pole / 3+N

The first is intended for suitable single-phase circuits and the second for suitable three-phase-plus-neutral systems.

Suitable for Electrical Panel Builders and Industrial Buyers

The Siemens 5SV4412-0RC is relevant for:

  • Electrical panel builders

  • Industrial buyers

  • Electrical contractors

  • Commercial electrical contractors

  • Facility-maintenance teams

  • OEMs

  • Machine builders

  • Electrical distributors

  • Industrial maintenance departments

  • Electrical product dealers

For SB Smart, the product is positioned as a Siemens Betagard/SENTRON 5SV4 Type AC RCCB for 25 A single-phase residual-current protection.

Technical Specification

SpecificationDetails
BrandSiemens
Product FamilySENTRON / Betagard 5SV4
Article Number5SV4412-0RC
Product TypeResidual Current Operated Circuit Breaker (RCCB)
RCCB TypeType AC
Rated Current25 A
Number of Poles2 Pole / 1+N
Residual Operating Current100 mA
Operating CharacteristicInstantaneous
Rated Operating Voltage230 V AC for corresponding Siemens 5SV4412-0
India Market Description240 V, 2MW
Module Width2 Modules
InstallationDIN-type modular installation
Operating Frequency50 Hz
Protection DegreeIP20 when installed with connected conductors in a suitable distribution board
Overvoltage CategoryIII
Pollution Degree2

These specifications are based on Siemens' 5SV4 product-selection documentation for the corresponding 5SV4412-0 article and Type AC 1P+N range.

Key Features

  • Siemens SENTRON / Betagard 5SV4 RCCB

  • Article number 5SV4412-0RC

  • 25 A rated current

  • 2-pole / 1+N configuration

  • 100 mA residual-current sensitivity

  • Type AC

  • Instantaneous residual-current operation

  • 230 V AC rated operating voltage for the corresponding Siemens article

  • 2-module modular format

  • DIN-type installation

  • Suitable for single-phase AC residual-current protection

  • Suitable for commercial, building and compatible industrial electrical panels

Benefits

  • 25 A rating: Suitable for compatible single-phase circuits and feeders.

  • 100 mA sensitivity: Provides residual-current protection at the specified operating threshold.

  • 2-pole / 1+N design: Suitable for phase-and-neutral single-phase systems.

  • Type AC: Designed for compatible sinusoidal AC residual currents.

  • Instantaneous operation: Provides residual-current disconnection without intentional short-time delay.

  • Compact 2-module format: Helps optimize space in modular distribution boards.

  • DIN modular installation: Supports convenient integration into standard protection assemblies.

  • SENTRON design: Provides a standardized Siemens residual-current protection solution.

Why Choose Siemens 5SV4412-0RC?

The Siemens 5SV4412-0RC is a compact 25 A, 2-pole / 1+N, Type AC RCCB with 100 mA residual-current sensitivity, intended for suitable single-phase AC installations. Siemens' product-selection data identifies the corresponding 5SV4412-0 within the instantaneous Type AC 1P+N, 230 V AC, 2-module RCCB range.

It is suitable for customers looking to buy or source Siemens SENTRON/Betagard 5SV4 RCCBs for single-phase distribution boards, commercial electrical panels, building installations and compatible industrial circuits in India.

For SB Smart, this product is best presented as a Siemens 5SV4 residual-current circuit breaker for 25 A single-phase electrical protection across India.

Delivery Across India

SB Smart supplies Siemens SENTRON/Betagard RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.

Major delivery locations include:

  • Faridabad

  • Delhi

  • Gurgaon/Gurugram

  • Delhi NCR

  • Noida

  • Greater Noida

  • Haryana

  • Punjab

  • Mumbai

  • Pune

  • Ahmedabad

  • Bengaluru

  • Hyderabad

  • Chennai

  • Kolkata

  • Jaipur

  • Chandigarh

  • Lucknow

  • Indore

  • Surat

  • Vadodara

  • Nagpur

  • Coimbatore

  • And other major cities across India

Frequently Asked Questions

1. What is Siemens 5SV4412-0RC?

The 5SV4412-0RC is a Siemens SENTRON 5SV4 residual-current operated circuit breaker rated at 25 A, with 2 poles / 1+N, 100 mA residual-current sensitivity and Type AC characteristics.

2. How many poles does it have?

It has 2 poles, configured for 1+N single-phase applications.

3. What is the rated current?

The rated current is 25 A.

4. What is the residual-current sensitivity?

The rated residual operating current is 100 mA.

5. What type of RCCB is it?

It is a Type AC RCCB intended for compatible AC residual-current protection.

6. Is it instantaneous?

Yes. The corresponding Siemens 5SV4412-0 is listed in the instantaneous Type AC 1P+N RCCB range.

7. What is the rated voltage?

Siemens' product-selection data specifies 230 V AC for the corresponding 5SV4412-0 article. The India-facing description uses 240 V terminology.

8. What does 2MW mean?

2MW means 2 module width in the modular installation format. It does not mean a 2 MW power rating.

9. What is the difference between 5SV4412-0RC and 5SV4612-0RC?

5SV4412-0RC: 25 A, 2-pole / 1+N, 100 mA, Type AC.

5SV4612-0RC: 25 A, 2-pole / 1+N, 300 mA, Type AC.

10. What is the difference between 5SV4412-0RC and 5SV4442-0RC?

5SV4412-0RC: 25 A, 2-pole / 1+N, 100 mA.

5SV4442-0RC: 25 A, 4-pole / 3+N, 100 mA.

The first is for suitable single-phase applications, while the second is for suitable three-phase-plus-neutral systems.

11. Is the 5SV4412-0RC an RCBO?

No. It is an RCCB. It provides residual-current protection; suitable overcurrent protection must be provided separately where required.

12. Where can I buy Siemens 5SV4412-0RC in India?

SB Smart supplies Siemens SENTRON/Betagard 5SV4 RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, commercial installations and maintenance requirements.

Technical Specifications

ParameterSpecification
Product SeriesSiemens 5SV
Part Number5SV4412-0RC
Product TypeRCCB (Residual Current Circuit Breaker)
Number of Poles2 Pole (variant dependent)
Rated Current (In)25A–63A (variant dependent)
Residual Sensitivity30mA / 100mA (variant dependent)
Rated Voltage (Ue)Up to 230/415V AC
Frequency50/60 Hz
Mounting TypeDIN Rail Mounting
Protection TypeEarth Leakage Protection
Standard ComplianceIEC 61008 / IEC standards (variant dependent)
ApplicationResidential, commercial & industrial protection

Customer Reviews

Write a Review

No reviews yet.

Why Buy From SB Smart?

Authorized Supplier
Genuine products directly from manufacturers with warranty support.
Industrial Expertise
Over 10 years of experience in industrial automation and electricals.
PAN India Delivery
Fast and secure shipping to all major industrial hubs across India.
Dedicated Support
Expert technical team available for product selection and support.

Request a Quote

×
Product: Product Name

Thank You!

Your quote request has been submitted successfully.

Our team will contact you shortly.

Product Enquiry

×
Enquiring for: Product Name

Enquiry Sent!

We have received your enquiry.

Our team will get back to you soon.