The Siemens 5SV4414-0RC is a SENTRON 5SV4 residual current operated circuit breaker (RCCB) designed for residual-current protection in suitable single-phase AC electrical installations. It has a 40 A rated current, 2-pole / 1+N configuration, 100 mA residual operating current, and Type AC residual-current protection. Siemens technical data identifies the corresponding 5SV4414-0 article as an instantaneous 2-pole Type AC RCCB with a 230 V AC rated operating voltage.
The India-facing product description specifies the device as a 240 V, 2-module-width RCCB, making it suitable for compatible single-phase distribution and protection applications in electrical panels.
The 5SV4414-0RC belongs to the Siemens SENTRON 5SV4 / Betagard RCCB family. Its purpose is to detect residual current in a protected circuit and disconnect the circuit when the residual current reaches the specified operating threshold.
The 2-pole / 1+N configuration is intended for single-phase circuits where phase and neutral are incorporated into the residual-current protection arrangement. Current Indian product listings identify the article as a 40 A, 2-pole, 100 mA, Type AC RCCB.
The RCCB has a rated current of 40 A.
This makes it suitable for compatible single-phase distribution circuits and feeders where a 40 A residual-current protection device is required.
The complete electrical installation should be designed so that the RCCB operates within its specified voltage, current and environmental conditions.
The 5SV4414-0RC has a rated residual operating current of 100 mA.
When the residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.
The 100 mA sensitivity should be selected according to the overall protection design and applicable electrical installation requirements. Product listings for the exact article confirm the 100 mA sensitivity.
The device is a Type AC RCCB.
Type AC residual-current circuit breakers are intended for compatible sinusoidal alternating residual currents. The correct RCCB type should always be selected according to the residual-current waveform that can occur in the actual installation.
The 5SV4414-0RC has 2 poles and is intended for 1+N single-phase applications.
The phase and neutral conductors can therefore be incorporated into the RCCB protection arrangement.
Typical applications include:
Single-phase distribution boards
Commercial electrical panels
Sub-distribution circuits
Equipment feeders
Building electrical installations
Small industrial electrical systems
Auxiliary power circuits
The supplied India product description identifies the device as a 240 V, 2-module RCCB. Siemens technical documentation for the corresponding 5SV4414-0 specifies 230 V AC rated operating voltage for the 2-pole Type AC article and a 230/400 V AC supply designation for the applicable family.
For the SB Smart listing, the India-facing 240 V description can be retained while the exact Siemens technical rating should be considered during product selection.
The 5SV4414-0RC is an instantaneous RCCB.
Siemens technical data for the corresponding 5SV4414-0 specifies that the switching function is not short-time delayed.
This means the device operates without an intentional short-time delay when the specified residual-current threshold is reached.
The corresponding Siemens 5SV4414-0 is specified with a 10 kA short-circuit current rating.
The RCCB should nevertheless be coordinated with appropriate upstream overcurrent protection and the prospective short-circuit conditions of the installation.
An RCCB primarily provides residual-current protection and should not be considered a replacement for an MCB or MCCB for overload and short-circuit protection unless the complete protection arrangement specifically provides those functions.
The India product description specifies 2MW, meaning 2 module width.
The 2MW designation refers to the physical modular width and does not indicate a 2 MW power rating. Indian product data identifies the device width at approximately 36 mm.
This compact arrangement is useful for:
Modular distribution boards
Consumer units
Commercial panels
Sub-distribution boards
Compact electrical enclosures
The 5SV4414-0RC is designed for modular electrical distribution installation. The corresponding Siemens 5SV4414-0 data identifies the product as a size-1 DIN 43880 installation device, supporting integration into standard modular protection assemblies.
This makes it convenient for panel builders and electricians working with standard modular distribution equipment.
The corresponding 5SV4 device is designed around standard modular distribution-board dimensions, including 60 mm grid spacing.
This supports installation alongside suitable MCBs, busbars and other compatible protection accessories.
Residual current can occur when part of the electrical current travels through an unintended path, such as an earth-leakage path.
The RCCB monitors the relevant current balance and disconnects the protected circuit when residual current reaches the configured 100 mA operating threshold.
This provides an additional protective layer within the overall electrical safety system.
The 5SV4414-0RC can be considered for compatible single-phase applications such as:
Commercial distribution boards
Building electrical panels
Sub-distribution systems
Equipment supply circuits
Office electrical installations
Single-phase feeder protection
Industrial auxiliary circuits
The final protection application should be determined according to the electrical design and applicable regulations.
An RCCB should generally be coordinated with suitable overcurrent protection where required.
A typical arrangement may include:
Incoming Supply → Overcurrent Protection → RCCB → Protected Load
The exact configuration depends on the electrical system, upstream protective device and applicable installation requirements.
RCCBs should be included in an appropriate electrical inspection and testing program.
The test function should be operated according to the manufacturer's instructions and applicable maintenance requirements to verify correct residual-current tripping.
Regular testing can help confirm that the protection mechanism remains operational.
Before selecting the 5SV4414-0RC, verify:
Rated current: 40 A
Residual-current sensitivity: 100 mA
RCCB type: Type AC
Pole configuration: 2-pole / 1+N
System voltage compatibility
Upstream overcurrent protection
Available panel space: 2 module width
Conductor size and termination
Applicable national electrical regulations
The 5SV4412-0RC is the corresponding 25 A, 2-pole / 1+N, 100 mA, Type AC RCCB, while the 5SV4414-0RC is rated at 40 A.
Therefore:
5SV4412-0RC → 25 A
5SV4414-0RC → 40 A
The key difference is the rated current of the protected circuit.
The 5SV4416-0RC is the corresponding 63 A, 2-pole / 1+N, 100 mA, Type AC RCCB.
Therefore:
5SV4414-0RC → 40 A
5SV4416-0RC → 63 A
Both are used for compatible single-phase applications with the same 100 mA Type AC residual-current characteristic.
The 5SV4614-0RC is the corresponding 40 A, 2-pole / 1+N, Type AC version with 300 mA residual-current sensitivity.
Therefore:
5SV4414-0RC → 40 A, 100 mA
5SV4614-0RC → 40 A, 300 mA
The residual-current threshold should be carefully verified when choosing a replacement.
The 5SV4314-0RC is the corresponding 40 A, 2-pole / 1+N, Type AC version with 30 mA residual-current sensitivity.
Therefore:
5SV4314-0RC → 40 A, 30 mA
5SV4414-0RC → 40 A, 100 mA
5SV4614-0RC → 40 A, 300 mA
This range allows selection according to the residual-current protection requirement.
The 5SV4444-0RC is a 40 A, 4-pole / 3+N, Type AC, 100 mA RCCB, whereas the 5SV4414-0RC is a 40 A, 2-pole / 1+N device.
Therefore:
5SV4414-0RC → 40 A, 2-pole / 1+N
5SV4444-0RC → 40 A, 4-pole / 3+N
The first is intended for suitable single-phase circuits and the second for suitable three-phase-plus-neutral systems.
The Siemens 5SV4414-0RC is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
Commercial electrical contractors
Facility-maintenance teams
OEMs
Machine builders
Electrical distributors
Industrial maintenance departments
Electrical product dealers
For SB Smart, the product is positioned as a Siemens Betagard/SENTRON 5SV4 Type AC RCCB for 40 A single-phase residual-current protection.
Siemens SENTRON / Betagard 5SV4 RCCB
Article number 5SV4414-0RC
40 A rated current
2-pole / 1+N configuration
100 mA residual-current sensitivity
Type AC
Instantaneous operation
230 V AC rated operating voltage for the corresponding Siemens article
2-module India market format
10 kA short-circuit current rating for the corresponding 5SV4414-0
DIN modular installation
Suitable for single-phase AC residual-current protection
40 A rating: Suitable for compatible higher-current single-phase distribution circuits.
100 mA sensitivity: Provides residual-current protection at the specified operating threshold.
2-pole / 1+N design: Suitable for phase-and-neutral single-phase systems.
Type AC: Designed for compatible sinusoidal AC residual currents.
Instantaneous operation: Provides rapid residual-current disconnection without intentional short-time delay.
Compact 2-module format: Helps save space in modular distribution boards.
DIN modular installation: Supports convenient integration into standard protection assemblies.
10 kA short-circuit rating: Supports coordination with suitable upstream protective equipment.
Siemens SENTRON design: Provides a standardized residual-current protection solution.
The Siemens 5SV4414-0RC is a 40 A, 2-pole / 1+N, Type AC RCCB with 100 mA residual-current sensitivity, designed for suitable single-phase AC electrical installations. Siemens technical data for the corresponding article specifies instantaneous operation, 230 V AC rated operating voltage, DIN 43880 size 1 and 10 kA short-circuit current rating.
It is suitable for customers looking to buy or source Siemens Betagard/SENTRON 5SV4 RCCBs for single-phase distribution boards, commercial installations, electrical panels and compatible industrial circuits in India.
For SB Smart, this product is best presented as a Siemens 5SV4 residual-current circuit breaker for 40 A single-phase electrical protection across India.
SB Smart supplies Siemens SENTRON/Betagard RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SV4414-0RC is a Siemens SENTRON 5SV4 residual-current operated circuit breaker rated at 40 A, with 2 poles / 1+N, 100 mA residual-current sensitivity and Type AC characteristics.
It has 2 poles, configured for 1+N single-phase applications.
The rated current is 40 A.
The rated residual operating current is 100 mA.
It is a Type AC RCCB for suitable AC residual-current protection.
Yes. The corresponding Siemens 5SV4414-0 is specified as an instantaneous RCCB.
The exact Siemens data specifies 230 V AC for the 2-pole article, while the India-facing product description uses 240 V terminology.
2MW means 2 module width in the modular installation format. It does not mean a 2 MW power rating.
The corresponding Siemens 5SV4414-0 is specified with a 10 kA short-circuit current rating.
5SV4414-0RC: 40 A, 2-pole / 1+N, 100 mA, Type AC.
5SV4412-0RC: 25 A, 2-pole / 1+N, 100 mA, Type AC.
5SV4414-0RC: 40 A, 2-pole / 1+N, 100 mA, Type AC.
5SV4614-0RC: 40 A, 2-pole / 1+N, 300 mA, Type AC.
SB Smart supplies Siemens Betagard/SENTRON 5SV4 RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, commercial installations and maintenance requirements.
| Parameter | Specification |
|---|---|
| Product Series | Siemens SENTRON 5SV |
| Part Number | 5SV4414-0RC |
| Product Type | RCCB (Residual Current Circuit Breaker) |
| Number of Poles | 2 Pole (1P+N) |
| Rated Current (In) | 40A |
| Sensitivity (IΔn) | 100mA |
| Rated Voltage | 230V AC |
| Type | Type AC |
| Mounting Type | DIN Rail |
| Frequency | 50/60 Hz |
| Breaking Capacity | 10 kA (variant dependent) |
| Application | Earth leakage protection |
No reviews yet.