RES.CUR.OP.CIRCUIT BREAKER TYPE AC 63A 1+N-POLE 100MA 240V 2MW INDIA - 5SV4416-0RC

(0 Reviews)
Best Price (Excl. GST):
3,176 / nos MRP: ₹9,075 / nos
GST (18%): 572
Total Price (Incl. GST): ₹3,748
You Save: ₹5,899 (65%)
Ready to Dispatch
Quantity:
nos
Secure
Fast Delivery
24/7 Support

100% Genuine Product

Industrial Grade

Quality Tested

GST Invoice Available

Product Description


Siemens 5SV4416-0RC RCCB – 63A, 2-Pole, 100mA, Type AC, 240V

The Siemens 5SV4416-0RC is a SENTRON 5SV4 residual current operated circuit breaker (RCCB) designed for residual-current protection in suitable single-phase AC electrical installations. It features a 63 A rated current, 2-pole / 1+N configuration, 100 mA residual-current sensitivity and Type AC residual-current protection. Siemens identifies the corresponding 5SV4416-0 as an instantaneous 2-pole Type AC RCCB, with a rated operating voltage of 230 V AC.

Siemens 5SV4416-0RC Residual Current Circuit Breaker

The 5SV4416-0RC belongs to the Siemens SENTRON 5SV4 RCCB family. Its purpose is to detect residual current in the protected circuit and disconnect the circuit when the residual current reaches the specified operating threshold.

The 2-pole / 1+N configuration is intended for single-phase circuits where phase and neutral are incorporated into the RCCB protection arrangement. Siemens' selection data lists 5SV4416-0 in the Type AC, 1P+N family at 63 A and 100 mA.

63 A Rated Current

The RCCB has a rated current of 63 A.

This makes the device suitable for compatible single-phase distribution circuits and feeders where a 63 A residual-current protection device is required.

The connected circuit should be designed so that the RCCB operates within its specified current, voltage and installation conditions.

100 mA Residual Current Sensitivity

The 5SV4416-0RC has a rated residual operating current of 100 mA.

When the residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.

The appropriate residual-current sensitivity should be selected according to the complete electrical protection design and applicable installation requirements. Siemens product data confirms the 100 mA tripping residual current for this article.

Type AC Residual Current Protection

This model is a Type AC RCCB.

Type AC residual-current devices are intended for compatible alternating sinusoidal residual currents. The correct RCCB type should be selected according to the residual-current waveform that can occur in the actual application.

2-Pole / 1+N Configuration

The 5SV4416-0RC has 2 poles and is designed for 1+N single-phase systems.

The arrangement allows both the phase and neutral conductors to be incorporated into the residual-current protection system.

Typical applications include:

  • Single-phase distribution boards

  • Commercial electrical panels

  • Sub-distribution circuits

  • Equipment feeders

  • Building electrical installations

  • Small industrial distribution circuits

  • Compatible auxiliary circuits

240 V AC / 230 V AC Application

The India-facing product description identifies the device as a 240 V, 2-module RCCB. Siemens' technical data for the exact 5SV4416-0 specifies 230 V AC rated operating voltage for this 2-pole Type AC article.

For accurate product content, it is preferable to describe the exact Siemens article as a 230 V AC RCCB, while retaining the 240 V India-market designation where required.

Instantaneous Operation

The 5SV4416-0RC is an instantaneous RCCB. Siemens specifies that the switching function is not short-time delayed.

This means the device responds without an intentionally introduced short-time delay when the specified residual-current threshold is reached.

10 kA Short-Circuit Current Rating

Siemens specifies a 10 kA short-circuit current rating for the corresponding 5SV4416-0 article.

The RCCB should nevertheless be coordinated with suitable upstream overcurrent protection and the prospective short-circuit level of the installation.

An RCCB primarily provides residual-current protection and should not be considered a substitute for an MCB or MCCB for overload and short-circuit protection unless the complete protection arrangement specifically provides those functions.

Compact 2-Module Design

The India product description specifies 2MW, meaning 2 module width.

The 2MW designation refers to the physical modular width and does not indicate a 2 MW power rating. Siemens' product documentation identifies the device as size 1 according to DIN 43880, with a physical width of approximately 36 mm.

This compact format makes it suitable for:

  • Modular distribution boards

  • Consumer units

  • Commercial panels

  • Sub-distribution boards

  • Compact industrial enclosures

DIN-Rail Installation

The 5SV4416-0RC is designed for DIN-rail mounting.

Siemens technical data specifies the mounting type as DIN rail (REG) and identifies the installation device as a compact modular unit.

This allows convenient integration into standard modular electrical protection assemblies.

60 mm Grid Spacing

The corresponding 5SV4416-0 device uses 60 mm grid spacing, supporting integration into conventional modular distribution-board arrangements.

Residual Current Protection

Residual current occurs when a portion of electrical current flows outside its intended path, such as through an unintended earth-leakage route.

The RCCB monitors the current balance in the circuit and disconnects the protected circuit when the residual current reaches the configured 100 mA threshold.

This provides an additional layer of protection within the overall electrical installation.

Single-Phase Distribution Applications

The 5SV4416-0RC can be considered for compatible single-phase applications such as:

  • Commercial distribution boards

  • Building electrical panels

  • Sub-distribution systems

  • Equipment supply circuits

  • Industrial auxiliary circuits

  • Office electrical installations

  • Single-phase feeder protection

The exact application should be determined by the electrical protection design and applicable regulations.

Protection Coordination

Because the RCCB provides residual-current protection, coordination with suitable upstream overcurrent protection is important.

A typical protection arrangement may include:

Incoming Supply → Overcurrent Protection → RCCB → Protected Load

The actual arrangement should be determined by the electrical system design, Siemens documentation and applicable local regulations.

Maintenance and Testing

RCCBs should be included in the electrical installation's regular inspection and testing program.

The test function should be operated according to the manufacturer's instructions and applicable maintenance requirements to verify correct residual-current tripping.

Regular testing helps confirm that the protective mechanism remains operational.

Installation Considerations

Before selecting the 5SV4416-0RC, verify:

  • Rated current: 63 A

  • Residual-current sensitivity: 100 mA

  • RCCB type: Type AC

  • Pole arrangement: 2-pole / 1+N

  • System voltage compatibility

  • Upstream overcurrent protection

  • Available panel space: 2 module width

  • Conductor size and termination

  • Applicable national electrical regulations

Siemens' product information also notes that use of certain RCCBs may be subject to national restrictions, so local installation requirements should be checked before use.

Difference from 40 A Version

The 5SV4414-0RC is the corresponding 40 A, 2-pole / 1+N, 100 mA, Type AC RCCB, while 5SV4416-0RC is rated at 63 A.

Therefore:

5SV4414-0RC → 40 A

5SV4416-0RC → 63 A

Siemens selection data lists both articles in the same Type AC, 1P+N, 100 mA family.

Difference from 25 A Version

The 5SV4412-0RC is the corresponding 25 A version with 2 poles, Type AC and 100 mA residual-current sensitivity.

Therefore:

5SV4412-0RC → 25 A

5SV4414-0RC → 40 A

5SV4416-0RC → 63 A

These models are selected according to the rated current required for the protected circuit.

Difference from 300 mA Version

The 5SV4616-0RC is the corresponding 63 A, 2-pole, Type AC version with 300 mA residual-current sensitivity.

Therefore:

5SV4416-0RC → 63 A, 100 mA

5SV4616-0RC → 63 A, 300 mA

The main difference is the residual-current operating threshold. Siemens' selection data separates these variants by residual-current sensitivity.

Difference from 30 mA Version

The 5SV4316-0 belongs to the corresponding 63 A, 2-pole Type AC, 30 mA range.

The 5SV4416-0RC is the 100 mA version.

Therefore, the article number must be checked carefully when selecting a replacement, particularly where the required residual-current sensitivity is specified by the protection design.

Difference from 4-Pole Version

The 5SV4446-0RC is a 63 A, 4-pole / 3+N, Type AC, 100 mA RCCB for three-phase-plus-neutral systems, whereas the 5SV4416-0RC is a 63 A, 2-pole / 1+N device for single-phase applications.

Therefore:

5SV4416-0RC → 63 A, 2-pole / 1+N

5SV4446-0RC → 63 A, 4-pole / 3+N

Suitable for Electrical Panel Builders and Industrial Buyers

The Siemens 5SV4416-0RC is relevant for:

  • Electrical panel builders

  • Industrial buyers

  • Electrical contractors

  • Commercial electrical contractors

  • Facility-maintenance teams

  • OEMs

  • Machine builders

  • Electrical distributors

  • Industrial maintenance departments

  • Electrical product dealers

For SB Smart, the product is positioned as a Siemens SENTRON/Betagard 5SV4 Type AC RCCB for 63 A single-phase residual-current protection.

Key Features

  • Siemens SENTRON 5SV4 RCCB

  • Article number 5SV4416-0RC

  • 63 A rated current

  • 2-pole / 1+N configuration

  • 100 mA residual-current sensitivity

  • Type AC

  • Instantaneous operation

  • 230 V AC rated voltage for the exact article

  • 2-module India market format

  • 10 kA short-circuit current rating

  • 2,000 V rated insulation voltage

  • DIN-rail mounting

  • 60 mm grid spacing

  • Suitable for single-phase residual-current protection

Benefits

  • 63 A rating: Suitable for compatible higher-current single-phase distribution circuits.

  • 100 mA sensitivity: Provides residual-current protection at the specified operating threshold.

  • 2-pole / 1+N design: Suitable for phase-and-neutral single-phase systems.

  • Type AC: Designed for compatible sinusoidal AC residual currents.

  • Instantaneous operation: Provides rapid residual-current disconnection without intentional short-time delay.

  • Compact 2-module format: Helps save space in modular distribution boards.

  • DIN-rail mounting: Supports convenient installation in standard electrical protection assemblies.

  • 10 kA short-circuit rating: Supports coordination with appropriate upstream protective equipment.

  • Siemens SENTRON design: Provides a standardized residual-current protection solution.

Why Choose Siemens 5SV4416-0RC?

The Siemens 5SV4416-0RC is a 63 A, 2-pole / 1+N, Type AC RCCB with 100 mA residual-current sensitivity, designed for suitable single-phase AC installations. Siemens' product data identifies the corresponding 5SV4416-0 article as an instantaneous RCCB with 230 V AC rated supply, 10 kA short-circuit rating and 2-module installation width.

It is suitable for customers looking to buy or source Siemens SENTRON 5SV4 RCCBs for single-phase distribution boards, commercial installations, electrical panels and compatible industrial circuits in India.

For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SV4 residual-current circuit breaker for 63 A single-phase electrical protection across India.

Delivery Across India

SB Smart supplies Siemens SENTRON protection devices, RCCBs and industrial electrical products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.

Major delivery locations include:

  • Faridabad

  • Delhi

  • Gurgaon/Gurugram

  • Delhi NCR

  • Noida

  • Greater Noida

  • Haryana

  • Punjab

  • Mumbai

  • Pune

  • Ahmedabad

  • Bengaluru

  • Hyderabad

  • Chennai

  • Kolkata

  • Jaipur

  • Chandigarh

  • Lucknow

  • Indore

  • Surat

  • Vadodara

  • Nagpur

  • Coimbatore

  • And other major cities across India

Frequently Asked Questions

1. What is Siemens 5SV4416-0RC?

The 5SV4416-0RC is a Siemens SENTRON 5SV4 residual-current operated circuit breaker rated at 63 A, with 2 poles / 1+N, 100 mA residual-current sensitivity and Type AC characteristics.

2. How many poles does it have?

It has 2 poles, configured for 1+N single-phase applications.

3. What is the rated current?

The rated current is 63 A.

4. What is the residual-current sensitivity?

The rated residual operating current is 100 mA.

5. What type of RCCB is it?

It is a Type AC RCCB intended for compatible AC residual-current protection.

6. Is it instantaneous?

Yes. Siemens identifies the device as instantaneous, with no short-time delayed switching function.

7. What is the voltage rating?

The exact Siemens 5SV4416-0 data specifies 230 V AC rated operating voltage. The India market description uses 240 V terminology.

8. What does 2MW mean?

2MW means 2 module width in the modular installation format. It does not mean a 2 MW power rating.

9. What is the short-circuit current rating?

The specified short-circuit current rating is 10 kA.

10. What is the difference between 5SV4416-0RC and 5SV4616-0RC?

5SV4416-0RC: 63 A, 2-pole / 1+N, Type AC, 100 mA

5SV4616-0RC: 63 A, 2-pole / 1+N, Type AC, 300 mA.

11. What is the difference between 5SV4416-0RC and 5SV4446-0RC?

5SV4416-0RC: 63 A, 2-pole / 1+N, 100 mA.

5SV4446-0RC: 63 A, 4-pole / 3+N, 100 mA.

The first is intended for single-phase circuits, while the second is for three-phase-plus-neutral systems.

12. Where can I buy Siemens 5SV4416-0RC in India?

SB Smart supplies Siemens SENTRON/Betagard 5SV4 RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, commercial installations and maintenance requirements.

Technical Specifications

ParameterSpecification
Product SeriesSiemens SENTRON 5SV
Part Number5SV4416-0RC
Product TypeRCCB (Residual Current Circuit Breaker)
Number of Poles2 Pole (1P+N)
Rated Current (In)63A
Residual Current (IΔn)100mA
Rated Voltage230/400V AC
TypeType AC
Mounting TypeDIN Rail
Frequency50/60 Hz
ApplicationEarth leakage protection

Customer Reviews

Write a Review

No reviews yet.

Why Buy From SB Smart?

Authorized Supplier
Genuine products directly from manufacturers with warranty support.
Industrial Expertise
Over 10 years of experience in industrial automation and electricals.
PAN India Delivery
Fast and secure shipping to all major industrial hubs across India.
Dedicated Support
Expert technical team available for product selection and support.

Request a Quote

×
Product: Product Name

Thank You!

Your quote request has been submitted successfully.

Our team will contact you shortly.

Product Enquiry

×
Enquiring for: Product Name

Enquiry Sent!

We have received your enquiry.

Our team will get back to you soon.