The Siemens 5SV4416-0RC is a SENTRON 5SV4 residual current operated circuit breaker (RCCB) designed for residual-current protection in suitable single-phase AC electrical installations. It features a 63 A rated current, 2-pole / 1+N configuration, 100 mA residual-current sensitivity and Type AC residual-current protection. Siemens identifies the corresponding 5SV4416-0 as an instantaneous 2-pole Type AC RCCB, with a rated operating voltage of 230 V AC.
The 5SV4416-0RC belongs to the Siemens SENTRON 5SV4 RCCB family. Its purpose is to detect residual current in the protected circuit and disconnect the circuit when the residual current reaches the specified operating threshold.
The 2-pole / 1+N configuration is intended for single-phase circuits where phase and neutral are incorporated into the RCCB protection arrangement. Siemens' selection data lists 5SV4416-0 in the Type AC, 1P+N family at 63 A and 100 mA.
The RCCB has a rated current of 63 A.
This makes the device suitable for compatible single-phase distribution circuits and feeders where a 63 A residual-current protection device is required.
The connected circuit should be designed so that the RCCB operates within its specified current, voltage and installation conditions.
The 5SV4416-0RC has a rated residual operating current of 100 mA.
When the residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.
The appropriate residual-current sensitivity should be selected according to the complete electrical protection design and applicable installation requirements. Siemens product data confirms the 100 mA tripping residual current for this article.
This model is a Type AC RCCB.
Type AC residual-current devices are intended for compatible alternating sinusoidal residual currents. The correct RCCB type should be selected according to the residual-current waveform that can occur in the actual application.
The 5SV4416-0RC has 2 poles and is designed for 1+N single-phase systems.
The arrangement allows both the phase and neutral conductors to be incorporated into the residual-current protection system.
Typical applications include:
Single-phase distribution boards
Commercial electrical panels
Sub-distribution circuits
Equipment feeders
Building electrical installations
Small industrial distribution circuits
Compatible auxiliary circuits
The India-facing product description identifies the device as a 240 V, 2-module RCCB. Siemens' technical data for the exact 5SV4416-0 specifies 230 V AC rated operating voltage for this 2-pole Type AC article.
For accurate product content, it is preferable to describe the exact Siemens article as a 230 V AC RCCB, while retaining the 240 V India-market designation where required.
The 5SV4416-0RC is an instantaneous RCCB. Siemens specifies that the switching function is not short-time delayed.
This means the device responds without an intentionally introduced short-time delay when the specified residual-current threshold is reached.
Siemens specifies a 10 kA short-circuit current rating for the corresponding 5SV4416-0 article.
The RCCB should nevertheless be coordinated with suitable upstream overcurrent protection and the prospective short-circuit level of the installation.
An RCCB primarily provides residual-current protection and should not be considered a substitute for an MCB or MCCB for overload and short-circuit protection unless the complete protection arrangement specifically provides those functions.
The India product description specifies 2MW, meaning 2 module width.
The 2MW designation refers to the physical modular width and does not indicate a 2 MW power rating. Siemens' product documentation identifies the device as size 1 according to DIN 43880, with a physical width of approximately 36 mm.
This compact format makes it suitable for:
Modular distribution boards
Consumer units
Commercial panels
Sub-distribution boards
Compact industrial enclosures
The 5SV4416-0RC is designed for DIN-rail mounting.
Siemens technical data specifies the mounting type as DIN rail (REG) and identifies the installation device as a compact modular unit.
This allows convenient integration into standard modular electrical protection assemblies.
The corresponding 5SV4416-0 device uses 60 mm grid spacing, supporting integration into conventional modular distribution-board arrangements.
Residual current occurs when a portion of electrical current flows outside its intended path, such as through an unintended earth-leakage route.
The RCCB monitors the current balance in the circuit and disconnects the protected circuit when the residual current reaches the configured 100 mA threshold.
This provides an additional layer of protection within the overall electrical installation.
The 5SV4416-0RC can be considered for compatible single-phase applications such as:
Commercial distribution boards
Building electrical panels
Sub-distribution systems
Equipment supply circuits
Industrial auxiliary circuits
Office electrical installations
Single-phase feeder protection
The exact application should be determined by the electrical protection design and applicable regulations.
Because the RCCB provides residual-current protection, coordination with suitable upstream overcurrent protection is important.
A typical protection arrangement may include:
Incoming Supply → Overcurrent Protection → RCCB → Protected Load
The actual arrangement should be determined by the electrical system design, Siemens documentation and applicable local regulations.
RCCBs should be included in the electrical installation's regular inspection and testing program.
The test function should be operated according to the manufacturer's instructions and applicable maintenance requirements to verify correct residual-current tripping.
Regular testing helps confirm that the protective mechanism remains operational.
Before selecting the 5SV4416-0RC, verify:
Rated current: 63 A
Residual-current sensitivity: 100 mA
RCCB type: Type AC
Pole arrangement: 2-pole / 1+N
System voltage compatibility
Upstream overcurrent protection
Available panel space: 2 module width
Conductor size and termination
Applicable national electrical regulations
Siemens' product information also notes that use of certain RCCBs may be subject to national restrictions, so local installation requirements should be checked before use.
The 5SV4414-0RC is the corresponding 40 A, 2-pole / 1+N, 100 mA, Type AC RCCB, while 5SV4416-0RC is rated at 63 A.
Therefore:
5SV4414-0RC → 40 A
5SV4416-0RC → 63 A
Siemens selection data lists both articles in the same Type AC, 1P+N, 100 mA family.
The 5SV4412-0RC is the corresponding 25 A version with 2 poles, Type AC and 100 mA residual-current sensitivity.
Therefore:
5SV4412-0RC → 25 A
5SV4414-0RC → 40 A
5SV4416-0RC → 63 A
These models are selected according to the rated current required for the protected circuit.
The 5SV4616-0RC is the corresponding 63 A, 2-pole, Type AC version with 300 mA residual-current sensitivity.
Therefore:
5SV4416-0RC → 63 A, 100 mA
5SV4616-0RC → 63 A, 300 mA
The main difference is the residual-current operating threshold. Siemens' selection data separates these variants by residual-current sensitivity.
The 5SV4316-0 belongs to the corresponding 63 A, 2-pole Type AC, 30 mA range.
The 5SV4416-0RC is the 100 mA version.
Therefore, the article number must be checked carefully when selecting a replacement, particularly where the required residual-current sensitivity is specified by the protection design.
The 5SV4446-0RC is a 63 A, 4-pole / 3+N, Type AC, 100 mA RCCB for three-phase-plus-neutral systems, whereas the 5SV4416-0RC is a 63 A, 2-pole / 1+N device for single-phase applications.
Therefore:
5SV4416-0RC → 63 A, 2-pole / 1+N
5SV4446-0RC → 63 A, 4-pole / 3+N
The Siemens 5SV4416-0RC is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
Commercial electrical contractors
Facility-maintenance teams
OEMs
Machine builders
Electrical distributors
Industrial maintenance departments
Electrical product dealers
For SB Smart, the product is positioned as a Siemens SENTRON/Betagard 5SV4 Type AC RCCB for 63 A single-phase residual-current protection.
Siemens SENTRON 5SV4 RCCB
Article number 5SV4416-0RC
63 A rated current
2-pole / 1+N configuration
100 mA residual-current sensitivity
Type AC
Instantaneous operation
230 V AC rated voltage for the exact article
2-module India market format
10 kA short-circuit current rating
2,000 V rated insulation voltage
DIN-rail mounting
60 mm grid spacing
Suitable for single-phase residual-current protection
63 A rating: Suitable for compatible higher-current single-phase distribution circuits.
100 mA sensitivity: Provides residual-current protection at the specified operating threshold.
2-pole / 1+N design: Suitable for phase-and-neutral single-phase systems.
Type AC: Designed for compatible sinusoidal AC residual currents.
Instantaneous operation: Provides rapid residual-current disconnection without intentional short-time delay.
Compact 2-module format: Helps save space in modular distribution boards.
DIN-rail mounting: Supports convenient installation in standard electrical protection assemblies.
10 kA short-circuit rating: Supports coordination with appropriate upstream protective equipment.
Siemens SENTRON design: Provides a standardized residual-current protection solution.
The Siemens 5SV4416-0RC is a 63 A, 2-pole / 1+N, Type AC RCCB with 100 mA residual-current sensitivity, designed for suitable single-phase AC installations. Siemens' product data identifies the corresponding 5SV4416-0 article as an instantaneous RCCB with 230 V AC rated supply, 10 kA short-circuit rating and 2-module installation width.
It is suitable for customers looking to buy or source Siemens SENTRON 5SV4 RCCBs for single-phase distribution boards, commercial installations, electrical panels and compatible industrial circuits in India.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SV4 residual-current circuit breaker for 63 A single-phase electrical protection across India.
SB Smart supplies Siemens SENTRON protection devices, RCCBs and industrial electrical products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SV4416-0RC is a Siemens SENTRON 5SV4 residual-current operated circuit breaker rated at 63 A, with 2 poles / 1+N, 100 mA residual-current sensitivity and Type AC characteristics.
It has 2 poles, configured for 1+N single-phase applications.
The rated current is 63 A.
The rated residual operating current is 100 mA.
It is a Type AC RCCB intended for compatible AC residual-current protection.
Yes. Siemens identifies the device as instantaneous, with no short-time delayed switching function.
The exact Siemens 5SV4416-0 data specifies 230 V AC rated operating voltage. The India market description uses 240 V terminology.
2MW means 2 module width in the modular installation format. It does not mean a 2 MW power rating.
The specified short-circuit current rating is 10 kA.
5SV4416-0RC: 63 A, 2-pole / 1+N, Type AC, 100 mA
5SV4616-0RC: 63 A, 2-pole / 1+N, Type AC, 300 mA.
5SV4416-0RC: 63 A, 2-pole / 1+N, 100 mA.
5SV4446-0RC: 63 A, 4-pole / 3+N, 100 mA.
The first is intended for single-phase circuits, while the second is for three-phase-plus-neutral systems.
SB Smart supplies Siemens SENTRON/Betagard 5SV4 RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, commercial installations and maintenance requirements.
| Parameter | Specification |
|---|---|
| Product Series | Siemens SENTRON 5SV |
| Part Number | 5SV4416-0RC |
| Product Type | RCCB (Residual Current Circuit Breaker) |
| Number of Poles | 2 Pole (1P+N) |
| Rated Current (In) | 63A |
| Residual Current (IΔn) | 100mA |
| Rated Voltage | 230/400V AC |
| Type | Type AC |
| Mounting Type | DIN Rail |
| Frequency | 50/60 Hz |
| Application | Earth leakage protection |
No reviews yet.