Siemens Logo

RES.CUR.OP.CIRCUIT BREAKER TYPE AC 40A 3+N-POLE 100MA 415V 4MW INDIA - 5SV4444-0RC

(0 Reviews)
Best Price (Excl. GST):
2,832 / nos MRP: ₹8,090 / nos
GST (18%): 510
Total Price (Incl. GST): ₹3,341
You Save: ₹5,259 (65%)
Ready to Dispatch
Quantity:
nos
Secure
Fast Delivery
24/7 Support

100% Genuine Product

Industrial Grade

Quality Tested

GST Invoice Available

Product Description


Siemens 5SV4444-0RC RCCB – 40A, 4-Pole, 100mA, Type AC, 415V

The Siemens 5SV4444-0RC is a SENTRON 5SV4 residual current operated circuit breaker (RCCB) designed for residual-current protection in suitable three-phase electrical installations with neutral. It is a 4-pole / 3+N, Type AC RCCB with a 40 A rated current and 100 mA rated residual operating current.

The device is suitable for compatible 415 V class three-phase AC distribution systems, including industrial, commercial and building electrical panels where 100 mA residual-current protection is required.

Siemens 5SV4444-0RC Residual Current Circuit Breaker

The 5SV4444-0RC belongs to the Siemens SENTRON 5SV4 RCCB family. Its purpose is to detect residual current in the protected circuit and disconnect the circuit when the residual current reaches the specified operating threshold.

The 4-pole / 3+N configuration is designed for three-phase systems with neutral, making it suitable for distribution boards, feeder circuits and electrical panels.

40 A Rated Current

The RCCB has a rated current of 40 A.

This makes it suitable for compatible three-phase distribution circuits and feeders where a 40 A RCCB is required.

The complete installation should be designed so that the RCCB operates within its rated electrical and environmental conditions.

100 mA Residual Current Sensitivity

The 5SV4444-0RC has a rated residual operating current of 100 mA.

When the residual current reaches the specified threshold, the RCCB trips and disconnects the protected circuit.

The 100 mA sensitivity should be selected according to the protection design and applicable electrical installation requirements.

Type AC Residual Current Protection

The device is a Type AC RCCB, intended for compatible sinusoidal alternating residual currents.

The RCCB type should always be selected according to the possible residual-current waveform in the actual installation.

4-Pole / 3+N Configuration

The 5SV4444-0RC provides 4 poles, making it suitable for three-phase plus neutral circuits.

This arrangement allows the three phase conductors and neutral to be incorporated into the residual-current protection system.

Typical applications include:

  • Three-phase distribution boards

  • PCC panels

  • MCC panels

  • Industrial feeder circuits

  • Commercial distribution panels

  • Factory electrical systems

  • Equipment supply circuits

415 V AC Three-Phase Application

The supplied India product description identifies the device for 415 V AC applications.

It is intended for suitable three-phase low-voltage distribution systems. The actual system voltage and wiring arrangement should be verified against the installation design and applicable Siemens documentation.

Instantaneous Operation

The 5SV4444-0RC is part of the Siemens 5SV4 Type AC RCCB range designed for instantaneous residual-current protection.

Instantaneous operation means there is no intentional short-time delay before the device responds when the specified residual-current threshold is reached.

Short-Circuit Protection and Coordination

An RCCB primarily provides residual-current protection. It should be coordinated with suitable upstream overcurrent protection such as an MCB or MCCB where required.

The complete protection arrangement should consider:

  • Prospective short-circuit current

  • Upstream protective device

  • Rated current

  • Conductor size

  • Electrical installation requirements

The RCCB should not be considered a replacement for an overcurrent protective device unless the overall protection arrangement specifically provides that function.

4-Module Design

The India product description specifies 4MW, meaning 4 module width.

The 4MW designation refers to the physical modular width of the device and does not represent a 4 MW power rating.

This format is suitable for:

  • Modular distribution boards

  • Electrical control panels

  • PCC panels

  • Sub-distribution boards

  • Commercial switchboards

  • Industrial protection assemblies

Modular Distribution Installation

The 5SV4 RCCB format supports integration into conventional modular electrical distribution assemblies.

The device can be installed alongside compatible MCBs, busbars and other protection accessories according to the panel design.

Residual Current Protection

Residual current occurs when part of the electrical current flows outside the intended circuit path, such as through an unintended earth-leakage path.

The RCCB monitors the relevant current balance and disconnects the circuit when the residual current reaches 100 mA.

This provides an additional level of protection within the overall electrical protection system.

Three-Phase Distribution Applications

The 5SV4444-0RC can be considered for compatible:

  • Industrial distribution boards

  • Commercial electrical panels

  • Three-phase feeder circuits

  • PCC and MCC panels

  • Factory electrical systems

  • Building distribution systems

  • Machine supply circuits

  • Sub-distribution boards

Industrial Panel Applications

The device is particularly relevant where the protection design requires:

40 A + 100 mA + Type AC + 4-pole / 3+N

This combination can be useful for selected three-phase distribution and feeder applications.

Maintenance and Testing

RCCBs should be included in the electrical installation's regular inspection and testing program.

The test function should be operated according to the manufacturer's instructions and applicable electrical-maintenance requirements to verify correct residual-current tripping.

Regular testing helps confirm that the protective mechanism remains functional.

Installation Considerations

Before selecting the 5SV4444-0RC, verify:

  • Rated current: 40 A

  • Residual-current sensitivity: 100 mA

  • RCCB type: Type AC

  • Pole configuration: 4-pole / 3+N

  • System voltage compatibility

  • Upstream overcurrent protection

  • Available panel space: 4 module width

  • Conductor size and termination

  • Applicable national electrical regulations

The correct RCCB type and sensitivity should always be selected according to the actual installation.

Difference from 40 A, 300 mA Version

The 5SV4644-0RC is the corresponding 40 A, 4-pole, Type AC RCCB with a 300 mA residual-current threshold.

Therefore:

5SV4444-0RC → 40 A, 100 mA

5SV4644-0RC → 40 A, 300 mA

The primary difference is the residual-current sensitivity.

Difference from 30 mA Version

Siemens also offers Type AC RCCBs with lower residual-current sensitivities such as 30 mA.

The 5SV4444-0RC is specifically the 100 mA version, so the article number and residual-current threshold should be verified carefully when selecting a replacement.

Difference from 63 A Version

The 5SV4446-0RC is rated at 63 A, while 5SV4444-0RC is rated at 40 A.

Both belong to the 4-pole Type AC family with a 100 mA residual-current threshold.

Therefore:

5SV4444-0RC → 40 A

5SV4446-0RC → 63 A

Difference from 25 A Version

The 5SV4442-0RC is the corresponding 25 A, 4-pole, Type AC, 100 mA version.

The 5SV4444-0RC is selected where a 40 A rated current is required.

Suitable for Electrical Panel Builders and Industrial Buyers

The Siemens 5SV4444-0RC is relevant for:

  • Electrical panel builders

  • Industrial buyers

  • Electrical contractors

  • Commercial electrical contractors

  • Facility-maintenance teams

  • Machine builders

  • OEMs

  • Electrical distributors

  • Factory maintenance departments

  • Electrical product dealers

For SB Smart, the product is positioned as a Siemens SENTRON 5SV4 Type AC RCCB for 40 A three-phase residual-current protection.

Key Features

  • Siemens SENTRON 5SV4 RCCB

  • Article number 5SV4444-0RC

  • 40 A rated current

  • 4-pole / 3+N configuration

  • 100 mA residual-current sensitivity

  • Type AC

  • Instantaneous residual-current operation

  • 415 V class three-phase application

  • 4-module India market format

  • Suitable for three-phase plus neutral circuits

  • Suitable for industrial and commercial distribution panels

  • Modular installation design

Benefits

  • 40 A rating: Suitable for compatible medium-current three-phase circuits.

  • 100 mA sensitivity: Provides residual-current protection at the specified threshold.

  • 4-pole / 3+N design: Suitable for three-phase plus neutral systems.

  • Type AC: Designed for compatible AC residual currents.

  • Instantaneous operation: Provides rapid residual-current disconnection without intentional delay.

  • 4-module format: Supports standard modular panel installation.

  • SENTRON 5SV4 design: Provides a standardized Siemens residual-current protection solution.

  • Industrial suitability: Suitable for PCC, MCC and distribution-panel applications.

Why Choose Siemens 5SV4444-0RC?

The Siemens 5SV4444-0RC is a 40 A, 4-pole / 3+N, Type AC RCCB with 100 mA residual-current sensitivity, designed for suitable three-phase AC electrical installations.

It is suitable for customers looking to buy or source Siemens SENTRON 5SV4 RCCBs for industrial distribution boards, commercial electrical panels, three-phase feeders and residual-current protection applications.

For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SV4 residual-current circuit breaker for 40 A three-phase electrical protection across India.

Delivery Across India

SB Smart supplies Siemens SENTRON protection devices, RCCBs and industrial electrical products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.

Major delivery locations include:

  • Faridabad

  • Delhi

  • Gurgaon/Gurugram

  • Delhi NCR

  • Noida

  • Greater Noida

  • Haryana

  • Punjab

  • Mumbai

  • Pune

  • Ahmedabad

  • Bengaluru

  • Hyderabad

  • Chennai

  • Kolkata

  • Jaipur

  • Chandigarh

  • Lucknow

  • Indore

  • Surat

  • Vadodara

  • Nagpur

  • Coimbatore

  • And other major cities across India

Frequently Asked Questions

1. What is Siemens 5SV4444-0RC?

The 5SV4444-0RC is a Siemens SENTRON 5SV4 residual-current operated circuit breaker rated at 40 A, with 4 poles / 3+N, 100 mA residual-current sensitivity and Type AC characteristics.

2. How many poles does it have?

It has 4 poles, suitable for three-phase plus neutral applications.

3. What is the rated current?

The rated current is 40 A.

4. What is the residual-current sensitivity?

The rated residual operating current is 100 mA.

5. What type of RCCB is it?

It is a Type AC residual-current circuit breaker.

6. Is it suitable for three-phase systems?

Yes. The 4-pole / 3+N configuration is designed for compatible three-phase plus neutral systems.

7. What does 4MW mean?

4MW means 4 module width in the modular installation format. It does not mean a 4 MW power rating.

8. What is the difference between 5SV4444-0RC and 5SV4644-0RC?

5SV4444-0RC: 40 A, 4-pole, Type AC, 100 mA

5SV4644-0RC: 40 A, 4-pole, Type AC, 300 mA

9. What is the difference between 5SV4444-0RC and 5SV4446-0RC?

5SV4444-0RC: 40 A, 4-pole, Type AC, 100 mA.

5SV4446-0RC: 63 A, 4-pole, Type AC, 100 mA.

10. Is the 5SV4444-0RC an RCBO?

No. It is an RCCB and primarily provides residual-current protection. Overcurrent protection must be provided by the appropriate upstream protective arrangement.

11. Can it be used with an MCB or MCCB?

Yes, an RCCB is normally coordinated with suitable overcurrent protection where required. The exact arrangement should follow the electrical protection design.

12. Where can I buy Siemens 5SV4444-0RC in India?

SB Smart supplies Siemens SENTRON 5SV4 RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, maintenance departments and distribution applications.

Technical Specifications

ParameterSpecification
Product SeriesSiemens SENTRON 5SV
Part Number5SV4444-0RC
Product TypeRCCB (Residual Current Circuit Breaker)
Number of Poles4 Pole (3P+N)
Rated Current (In)40A
Residual Current (IΔn)100mA
Rated Voltage400V AC
TypeType AC
Mounting TypeDIN Rail
Breaking Capacity10 kA (series dependent)
Frequency50/60 Hz
ApplicationEarth leakage protection

Customer Reviews

Write a Review

No reviews yet.

Why Buy From SB Smart?

Authorized Supplier
Genuine products directly from manufacturers with warranty support.
Industrial Expertise
Over 10 years of experience in industrial automation and electricals.
PAN India Delivery
Fast and secure shipping to all major industrial hubs across India.
Dedicated Support
Expert technical team available for product selection and support.

Request a Quote

×
Product: Product Name

Thank You!

Your quote request has been submitted successfully.

Our team will contact you shortly.

Product Enquiry

×
Enquiring for: Product Name

Enquiry Sent!

We have received your enquiry.

Our team will get back to you soon.