The Siemens 5SV4446-0RC is a SENTRON 5SV4 residual current operated circuit breaker (RCCB) designed for protection against residual AC currents in three-phase electrical installations with neutral. It is a 4-pole / 3+N Type AC RCCB with a 63 A rated current and 100 mA rated residual operating current. The device is intended for suitable 230/400 V AC distribution systems and is suitable for modular electrical panels and distribution boards.
The 5SV4446-0RC belongs to the Siemens SENTRON 5SV4 RCCB family. Its function is to detect residual current in the protected circuit and disconnect the circuit when the residual current reaches its specified operating threshold.
The 4-pole configuration is suitable for three-phase plus neutral circuits, making the device appropriate for industrial, commercial and building electrical distribution systems.
The RCCB has a rated current of 63 A.
This makes the device suitable for compatible distribution feeders and electrical circuits designed for a 63 A residual-current protection device.
The complete protection arrangement should ensure that the device is operated within its rated current and installation conditions.
The 5SV4446-0RC has a rated residual operating current of 100 mA.
When the residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.
The 100 mA sensitivity should be selected according to the electrical protection design and applicable installation requirements.
The device is a Type AC RCCB and is intended for compatible sinusoidal alternating residual currents.
The correct RCCB type should always be selected according to the residual-current waveform that can occur in the installation.
The 5SV4446-0RC uses a 4-pole configuration, suitable for three-phase plus neutral electrical systems.
This arrangement allows the phases and neutral to be included in the residual-current protection scheme.
Typical applications include:
Three-phase distribution boards
Industrial feeder circuits
Commercial electrical panels
PCC panels
Sub-distribution boards
Machine supply circuits
Factory electrical systems
The India-facing product description identifies the device as 415 V AC. For compatible three-phase low-voltage systems, the device is used in the typical 240/415 V AC phase-neutral/phase-phase arrangement.
The actual system voltage and wiring must be verified against the applicable Siemens documentation and the electrical installation design.
The 5SV4446-0RC belongs to the Siemens 5SV4 Type AC instantaneous RCCB range.
An instantaneous RCCB operates without an intentionally introduced short-time delay when the residual-current trip threshold is reached.
This makes it suitable where instantaneous residual-current protection is specified by the protection design.
The Siemens 5SV4 range provides short-circuit coordination characteristics for suitable installations.
The RCCB should be installed with appropriate upstream overcurrent protection and coordinated with the prospective short-circuit current of the electrical system.
An RCCB primarily provides residual-current protection and should not be considered a replacement for an MCB or MCCB for overload and short-circuit protection unless the complete protection arrangement specifically provides those functions.
The India product description specifies 4MW, meaning a 4-module-width modular installation format.
The 4MW designation refers to physical module width and does not indicate a 4 MW power rating.
The modular format is suitable for:
Distribution boards
Electrical control panels
Commercial panels
Industrial protection assemblies
Sub-distribution systems
The 5SV4 RCCB design is intended for standard modular electrical distribution installations with conventional grid spacing.
This supports integration into distribution-board assemblies alongside compatible MCBs, busbars and accessories.
Residual current occurs when some electrical current leaves the intended circuit path, for example through an unintended earth-leakage path.
The RCCB monitors the circuit and trips when the residual current reaches the 100 mA operating threshold.
This provides an additional layer of electrical protection within the overall installation protection scheme.
The 5SV4446-0RC is suitable for compatible three-phase plus neutral applications such as:
Main distribution boards
Sub-distribution boards
Industrial feeders
Commercial distribution panels
Factory electrical systems
Building electrical installations
Equipment feeders
Electrical control panels
Panel builders can use the device where the protection design requires:
63 A + 100 mA + Type AC + 4-pole / 3+N
This makes the RCCB suitable for three-phase circuits where a 100 mA residual-current threshold is specified.
RCCBs should be included in the electrical installation's routine inspection and testing program.
The test function should be operated according to the manufacturer's instructions and applicable electrical-maintenance requirements to verify correct residual-current tripping.
Regular testing can help confirm that the protective mechanism remains operational.
Before selecting the 5SV4446-0RC, verify:
Rated current: 63 A
Residual-current sensitivity: 100 mA
RCCB type: Type AC
Pole configuration: 4-pole / 3+N
System voltage: compatible 3-phase AC supply
Upstream overcurrent protection
Panel space: 4 module width
Conductor size and termination
Applicable national electrical regulations
The correct RCCB sensitivity and type should always be selected according to the actual electrical installation and protection scheme.
The 5SV4646-0RC is the corresponding 63 A, 4-pole, Type AC RCCB with a 300 mA residual-current sensitivity.
Therefore:
5SV4446-0RC → 63 A, 100 mA
5SV4646-0RC → 63 A, 300 mA
The main difference is the residual-current operating threshold.
The corresponding 30 mA version belongs to the same 63 A, 4-pole Type AC family but provides a lower residual-current operating threshold.
Therefore, the selection should be based on whether the application requires:
30 mA
100 mA
300 mA
The correct sensitivity depends on the intended protection function and applicable standards.
The 5SV4447-0RC is the higher-current 80 A version, whereas the 5SV4446-0RC is rated at 63 A.
Both are used as 4-pole Type AC RCCBs with the corresponding residual-current sensitivity.
The 5SV4646-0RC has:
63 A + 4-pole + Type AC + 300 mA
The 5SV4446-0RC has:
63 A + 4-pole + Type AC + 100 mA
This distinction is important when selecting a replacement device.
The Siemens 5SV4446-0RC is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
Commercial electrical contractors
Facility-maintenance teams
Machine builders
OEMs
Electrical distributors
Industrial maintenance departments
Electrical product dealers
For SB Smart, the product is positioned as a Siemens SENTRON 5SV4 Type AC RCCB for 63 A three-phase residual-current protection.
Siemens SENTRON 5SV4 RCCB
Article number 5SV4446-0RC
63 A rated current
4-pole / 3+N configuration
100 mA residual-current sensitivity
Type AC
Instantaneous operation
Suitable for 415 V class three-phase systems
4-module India market format
Suitable for three-phase plus neutral electrical networks
Designed for modular distribution boards
Suitable for industrial and commercial electrical protection applications
63 A rating: Suitable for compatible higher-current three-phase distribution circuits.
100 mA sensitivity: Provides residual-current protection at the specified operating threshold.
4-pole / 3+N configuration: Suitable for three-phase plus neutral systems.
Type AC: Designed for compatible sinusoidal AC residual currents.
Instantaneous response: Provides residual-current disconnection without intentional short-time delay.
4-module format: Fits standard modular distribution arrangements.
SENTRON 5SV4 design: Provides a standardized Siemens residual-current protection solution.
Industrial suitability: Suitable for PCC panels, distribution boards and industrial feeder circuits.
The Siemens 5SV4446-0RC is a 63 A, 4-pole / 3+N, Type AC RCCB with 100 mA residual-current sensitivity, designed for compatible three-phase AC electrical systems.
It provides a practical Siemens solution for residual-current protection in industrial, commercial and building distribution systems where a 100 mA operating threshold is required.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SV4 residual-current circuit breaker for 63 A three-phase electrical protection across India.
SB Smart supplies Siemens SENTRON protection devices, RCCBs and industrial electrical products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SV4446-0RC is a Siemens SENTRON 5SV4 residual-current operated circuit breaker rated at 63 A, with 4 poles / 3+N, 100 mA residual-current sensitivity and Type AC characteristics.
It has 4 poles, suitable for three-phase plus neutral applications.
The rated current is 63 A.
The rated residual operating current is 100 mA.
It is a Type AC residual-current circuit breaker intended for compatible AC residual currents.
Yes. Its 4-pole / 3+N configuration is intended for compatible three-phase plus neutral systems.
4MW means 4 module width in the modular installation format. It does not mean a 4 MW power rating.
5SV4446-0RC: 63 A, 4-pole, Type AC, 100 mA
5SV4646-0RC: 63 A, 4-pole, Type AC, 300 mA
No. It is an RCCB. It provides residual-current protection but does not itself provide the complete overload and short-circuit protection of an RCBO.
A 100 mA RCCB can be used where the electrical protection design specifies this residual-current sensitivity, such as suitable distribution and feeder applications. The exact application should be determined by the installation design and applicable electrical regulations.
Yes, an RCCB is commonly coordinated with appropriate overcurrent protection such as an MCB or MCCB where required. The exact protection arrangement should follow the system design.
SB Smart supplies Siemens SENTRON 5SV4 RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, maintenance departments and distribution applications.
| Parameter | Specification |
|---|---|
| Product Series | Siemens SENTRON 5SV |
| Part Number | 5SV4446-0RC |
| Product Type | RCCB (Residual Current Circuit Breaker) |
| Number of Poles | 4 Pole (3P+N) |
| Rated Current (In) | 63A |
| Residual Current (IΔn) | 100mA |
| Rated Voltage | 400V AC |
| Type | Type AC |
| Mounting Type | DIN Rail |
| Frequency | 50/60 Hz |
| Breaking Capacity | 10 kA (series dependent) |
| Application | Earth leakage protection |
No reviews yet.