RES.CUR.OP.CIRCUIT BREAKER TYPE AC 40A 1+N-POLE 300MA 240V 2MW INDIA - 5SV4614-0RC

(0 Reviews)
Best Price (Excl. GST):
2,559 / nos MRP: ₹7,310 / nos
GST (18%): 461
Total Price (Incl. GST): ₹3,019
You Save: ₹4,752 (65%)
Ready to Dispatch
Quantity:
nos
Secure
Fast Delivery
24/7 Support

100% Genuine Product

Industrial Grade

Quality Tested

GST Invoice Available

Product Description


Siemens 5SV4614-0RC RCCB – 40A, 2-Pole, 300mA, Type AC, 240V

The Siemens 5SV4614-0RC is a SENTRON 5SV4 residual current operated circuit breaker (RCCB) designed for suitable single-phase AC electrical installations requiring residual-current protection. It has a 40 A rated current, 2-pole / 1+N configuration, 300 mA residual operating current, and Type AC residual-current characteristic. Siemens identifies the article as an active RCCB and specifies 230 V AC for this 2-pole Type AC version.

The India-facing product description identifies this model as a 240 V, 2-module RCCB, making it suitable for compatible single-phase distribution and protection applications.

Siemens 5SV4614-0RC Residual Current Circuit Breaker

The 5SV4614-0RC belongs to the Siemens SENTRON 5SV4 RCCB family. Its main function is to disconnect the protected circuit when an unwanted residual current reaches the specified operating threshold.

The 2-pole / 1+N configuration is intended for single-phase circuits where phase and neutral are incorporated into the RCCB switching arrangement.

Siemens' Industry Mall identifies the exact article as a 2-pole, Type AC RCCB, In 40 A, 300 mA, Un AC 230 V.

40 A Rated Current

The RCCB has a rated current of 40 A.

This makes the device suitable for compatible single-phase distribution circuits and feeders where a 40 A residual-current protection device is required.

The connected installation should be designed so the RCCB operates within its specified current, voltage and environmental conditions.

300 mA Residual Current Sensitivity

The 5SV4614-0RC has a rated residual operating current of 300 mA.

When the residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.

The correct residual-current sensitivity must be selected according to the complete electrical protection design and applicable installation requirements.

Type AC Residual Current Protection

This model is a Type AC RCCB.

Type AC residual-current devices are intended for sinusoidal alternating residual currents. The RCCB type should always be selected according to the residual-current waveform that can occur in the actual installation.

2-Pole / 1+N Configuration

The 5SV4614-0RC has 2 poles and is designed for 1+N single-phase applications.

The arrangement allows the phase and neutral conductors to be incorporated into the residual-current protection system.

Typical applications include:

  • Single-phase distribution boards

  • Commercial electrical panels

  • Sub-distribution circuits

  • Small industrial feeders

  • Equipment supply circuits

  • Building electrical installations

  • Compatible control and auxiliary circuits

240 V AC / 230 V AC System Compatibility

The supplied India product description identifies the article as a 240 V, 2-module RCCB. Siemens' Industry Mall description for the exact article specifies 230 V AC for the 2-pole Type AC version.

For accurate product-page content, it is preferable to describe the device as a 230 V AC Type AC RCCB, while retaining 240 V only where required by the India market-facing designation.

Instantaneous Operation

The 5SV4614-0RC is an instantaneous RCCB. Siemens' product information lists the device in its instantaneous Type AC 1P+N RCCB range.

This means the RCCB is intended to respond without an intentional short-time delay when the specified residual-current threshold is reached.

10 kA Short-Circuit Rating

The 5SV4 RCCB family provides short-circuit coordination characteristics for appropriate installations. The exact short-circuit protection arrangement must be coordinated with suitable upstream overcurrent protection and the prospective short-circuit level of the installation.

An RCCB is primarily a residual-current protection device and should not be treated as a substitute for an MCB or other overcurrent protective device unless the complete protection system specifically provides the required protection.

Compact 2-Module Design

The India product designation specifies 2MW, meaning a 2-module width in a modular installation format. It does not refer to a 2 MW power rating.

This compact format is suitable for:

  • Modular distribution boards

  • Consumer units

  • Commercial panels

  • Sub-distribution boards

  • Control panels

  • Compact electrical enclosures

The Siemens 5SV4 Type AC 1P+N range is documented as a 2-module-width device family.

DIN Modular Installation

The 5SV4614-0RC is designed as a modular RCCB for installation in suitable electrical distribution assemblies.

The compact modular design helps panel builders organize protection devices efficiently while leaving space for compatible MCBs, busbars and accessories.

Residual Current Protection

Residual current can occur when part of the electrical current flows through an unintended path, such as leakage to earth.

The RCCB monitors the relevant current balance and trips when the residual current reaches the configured 300 mA threshold.

This provides an additional layer of electrical protection for the connected circuit.

Single-Phase Distribution Applications

The 5SV4614-0RC can be considered for compatible single-phase circuits such as:

  • Commercial distribution boards

  • Building electrical panels

  • Sub-distribution circuits

  • Single-phase equipment feeders

  • Auxiliary power circuits

  • Small industrial electrical systems

  • Office electrical installations

The actual protection application should be determined by the electrical design and applicable standards.

Protection Coordination

Because the RCCB provides residual-current protection, appropriate coordination with upstream overcurrent protection is important.

The complete protection system may include:

Incoming Supply → MCB/MCCB/Overcurrent Protection → RCCB → Protected Load

The exact arrangement should follow the electrical design, Siemens documentation and applicable local regulations.

Maintenance and Testing

RCCBs should be included in an appropriate electrical inspection and testing program.

The device's test function should be operated according to the manufacturer's instructions and applicable electrical-maintenance requirements to verify that the residual-current tripping mechanism remains operational.

Installation Considerations

Before selecting the 5SV4614-0RC, verify:

  • Rated current: 40 A

  • Residual-current sensitivity: 300 mA

  • RCCB type: Type AC

  • Pole configuration: 2-pole / 1+N

  • System voltage compatibility

  • Upstream overcurrent protection

  • Available module space

  • Conductor size and termination

  • Applicable national installation regulations

Siemens explicitly notes that use of these devices is not permitted in all countries and that national installation regulations must be observed.

Difference from 25 A Version

The 5SV4612-0RC is the corresponding 25 A, 2-pole / 1+N, 300 mA, Type AC RCCB, while 5SV4614-0RC is rated at 40 A.

Therefore:

5SV4612-0RC → 25 A

5SV4614-0RC → 40 A

Both are part of the 1P+N Type AC 300 mA RCCB range.

Difference from 63 A Version

The 5SV4616-0 belongs to the same general Type AC, 1P+N family with a higher 63 A current rating.

The 5SV4614-0RC should be selected specifically for circuits requiring a 40 A rated RCCB.

Difference from 30 mA Version

The 5SV4 Type AC 1P+N family includes lower residual-current sensitivities such as 30 mA as well as 300 mA variants. Siemens' selection guide lists the Type AC 1P+N range across different residual operating currents and current ratings.

The key distinction is:

5SV4614-0RC → 40 A, 300 mA

A different article must be selected where a different residual-current threshold is required.

Difference from 100 mA Version

Siemens also provides Type AC RCCBs with a 100 mA residual-current sensitivity.

The 5SV4614-0RC is specifically the 300 mA version, so the residual-current threshold should be verified carefully when selecting a replacement.

Suitable for Electrical Panel Builders and Industrial Buyers

The Siemens 5SV4614-0RC is relevant for:

  • Electrical panel builders

  • Industrial buyers

  • Electrical contractors

  • Commercial electrical contractors

  • Facility-maintenance teams

  • OEMs

  • Machine builders

  • Electrical distributors

  • Electrical product dealers

  • Maintenance departments

For SB Smart, the product is positioned as a Siemens SENTRON 5SV4 Type AC RCCB for 40 A single-phase residual-current protection.

Key Features

  • Siemens SENTRON 5SV4 RCCB

  • Article number 5SV4614-0RC

  • 40 A rated current

  • 2-pole / 1+N configuration

  • 300 mA residual-current sensitivity

  • Type AC

  • Instantaneous operation

  • 230 V AC rated supply for the exact 2-pole article

  • 2-module India market format

  • Suitable for single-phase AC residual-current protection

  • Suitable for modular distribution boards

  • Designed for compatible commercial and industrial electrical installations

Benefits

  • 40 A rating: Suitable for compatible higher-current single-phase circuits.

  • 300 mA sensitivity: Provides residual-current protection at the specified operating threshold.

  • 2-pole / 1+N design: Suitable for phase-and-neutral single-phase systems.

  • Type AC: Designed for compatible sinusoidal AC residual currents.

  • Instantaneous operation: Provides rapid disconnection without intentional short-time delay.

  • Compact 2-module format: Helps optimize space in modular distribution boards.

  • SENTRON product family: Provides a standardized Siemens residual-current protection solution.

  • Easy panel integration: Suitable for conventional modular electrical protection assemblies.

Why Choose Siemens 5SV4614-0RC?

The Siemens 5SV4614-0RC is a 40 A, 2-pole / 1+N, Type AC RCCB with 300 mA residual-current sensitivity, designed for suitable single-phase AC installations. Siemens' Industry Mall identifies the exact article as an active 2-pole Type AC RCCB, In 40 A, 300 mA, Un AC 230 V.

It is suitable for customers looking to buy or source Siemens SENTRON 5SV4 RCCBs for single-phase distribution boards, commercial installations, electrical panels and compatible industrial circuits in India.

For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SV4 residual-current circuit breaker for 40 A single-phase electrical protection across India.

Delivery Across India

SB Smart supplies Siemens SENTRON protection devices and industrial electrical products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.

Major delivery locations include:

  • Faridabad

  • Delhi

  • Gurgaon/Gurugram

  • Delhi NCR

  • Noida

  • Greater Noida

  • Haryana

  • Punjab

  • Mumbai

  • Pune

  • Ahmedabad

  • Bengaluru

  • Hyderabad

  • Chennai

  • Kolkata

  • Jaipur

  • Chandigarh

  • Lucknow

  • Indore

  • Surat

  • Vadodara

  • Nagpur

  • Coimbatore

  • And other major cities across India

Frequently Asked Questions

1. What is Siemens 5SV4614-0RC?

The 5SV4614-0RC is a Siemens SENTRON 5SV4 residual-current operated circuit breaker rated at 40 A, with 2 poles / 1+N, 300 mA residual-current sensitivity and Type AC characteristics.

2. How many poles does it have?

It has 2 poles, configured for 1+N single-phase applications.

3. What is the rated current?

The rated current is 40 A.

4. What is the residual-current sensitivity?

The rated residual operating current is 300 mA.

5. What type of RCCB is it?

It is a Type AC RCCB designed for suitable AC residual-current protection.

6. Is it instantaneous?

Yes. The 5SV4 Type AC 1P+N range includes instantaneous RCCBs, and the 5SV4614 article is identified within this range.

7. What is the rated voltage?

Siemens' Industry Mall specifies 230 V AC for the exact 2-pole article. The India-facing description uses 240 V terminology for the 2-module product.

8. What does 2MW mean?

2MW means 2 module width in the modular installation format. It does not mean a 2 MW power rating.

9. What is the difference between 5SV4614-0RC and 5SV4612-0RC?

5SV4614-0RC: 40 A, 2-pole / 1+N, 300 mA, Type AC.

5SV4612-0RC: 25 A, 2-pole / 1+N, 300 mA, Type AC.

10. Is 5SV4614-0RC an RCBO?

No. It is an RCCB. It provides residual-current protection but does not itself combine residual-current and overcurrent protection like an RCBO.

11. Can it be used in a single-phase distribution board?

Yes, where the electrical protection design calls for a 40 A, 2-pole / 1+N, 300 mA Type AC RCCB and the installation is compatible with the device.

12. Where can I buy Siemens 5SV4614-0RC in India?

SB Smart supplies Siemens SENTRON 5SV4 RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, commercial installations and maintenance requirements.

Technical Specifications

ParameterSpecification
Product SeriesSiemens SENTRON 5SV
Part Number5SV4614-0RC
Product TypeRCCB (Residual Current Circuit Breaker)
Number of Poles2 Pole (1P+N)
Rated Current (In)40A
Residual Current (IΔn)300mA
Rated Voltage230/400V AC
TypeType AC
Mounting TypeDIN Rail
Frequency50/60 Hz
ApplicationEarth leakage & fire protection

Customer Reviews

Write a Review

No reviews yet.

Why Buy From SB Smart?

Authorized Supplier
Genuine products directly from manufacturers with warranty support.
Industrial Expertise
Over 10 years of experience in industrial automation and electricals.
PAN India Delivery
Fast and secure shipping to all major industrial hubs across India.
Dedicated Support
Expert technical team available for product selection and support.

Request a Quote

×
Product: Product Name

Thank You!

Your quote request has been submitted successfully.

Our team will contact you shortly.

Product Enquiry

×
Enquiring for: Product Name

Enquiry Sent!

We have received your enquiry.

Our team will get back to you soon.