The Siemens 3WT8101-6KN24-5AB2 is a SENTRON 3WT8 withdrawable air circuit breaker (ACB) designed for high-current low-voltage power distribution applications. The specified configuration features 3 poles, Size 1, 1000A rated current, and 66kA Icu at 500V AC, with operation at 50/60Hz.
The withdrawable construction allows convenient isolation and removal of the circuit breaker for inspection and maintenance. The configuration includes a mechanical lockout device, tripped signaling switch, tripped indicators and guide frame, supporting operational control and maintenance requirements. Siemens documentation confirms the 3WT8 family includes Size 1, 1000A, 3-pole withdrawable breakers with 66kA breaking capacity at 500V.
The Siemens 3WT8101-6KN24-5AB2 is suitable for:
The 66kA Icu at 500V AC makes this ACB suitable for demanding low-voltage distribution systems with high fault-current levels.
Its withdrawable design allows the breaker to be moved out of the connected position for inspection, servicing and replacement.
The mechanical lockout, tripped signaling switch and tripped indicators provide useful status and safety functions during operation and maintenance.
With a 1000A rated current, the breaker is suitable for major feeders and high-capacity distribution circuits.
The Siemens 3WT8 range is designed for low-voltage power distribution and includes different current ratings, pole configurations and withdrawable/fixed installation options. Siemens' catalog data confirms the 3WT8 family supports high-current applications up to 4000A and 66kA breaking capacity configurations.
Looking for a Siemens 3WT8101-6KN24-5AB2 ACB supplier in India? SB Smart supplies Siemens ACBs, MCCBs, circuit breakers, switchgear and industrial electrical products for panel builders, OEMs, electrical contractors and system integrators.
We supply Siemens products across Delhi, Faridabad, Gurugram, Noida, Punjab, Mumbai and major cities across India.
1. What is Siemens 3WT8101-6KN24-5AB2?
It is a Siemens SENTRON 3WT8 withdrawable air circuit breaker for high-current low-voltage power distribution.
2. What is the rated current?
The rated current is 1000A.
3. How many poles does this ACB have?
It is a 3-pole air circuit breaker.
4. What is the breaking capacity?
The specified Icu is 66kA at 500V AC.
5. Is the Siemens 3WT8101-6KN24-5AB2 withdrawable?
Yes. It is a withdrawable circuit breaker supplied with a guide frame.
6. What additional features are included?
The specified configuration includes a mechanical lockout device, tripped signaling switch, tripped indicators and guide frame.
7. Where can this ACB be used?
It is suitable for industrial power distribution, main switchboards, low-voltage switchgear, manufacturing plants and high-current feeder applications.
| Parameter | Specification |
|---|---|
| Product Series | Siemens SENTRON 3WT |
| Model Number | 3WT8101-6KN24-5AB2 |
| Product Type | Air Circuit Breaker (ACB) |
| Rated Current | ~1000 A (typical 3WT8101 frame class) |
| Poles | 3 Pole |
| Trip Unit | Microprocessor-based Electronic Trip Unit (ETU) |
| Protection Functions | Overload, Short Circuit, Earth Fault |
| Mounting Type | Withdrawable / Draw-out type |
| Application | Industrial / Commercial Power Distribution |
| Brand | Siemens |