The Siemens 3WT8101-6AA04-5AB2 is a SENTRON 3WT8 withdrawable Air Circuit Breaker (ACB) designed for high-current low-voltage power distribution and protection applications. It is a 3-pole, Size 1 circuit breaker with a rated current of 1000 A, suitable for operation up to 500 V AC at 50/60 Hz. The specified ultimate short-circuit breaking capacity (Icu) is 66 kA at 500 V AC. Siemens and corresponding technical documentation identify this exact MLFB with an ETU37WT LSING electronic overcurrent release with display.
The breaker uses a manual draw-out (MDO) withdrawable construction with guide frame, making it suitable for switchboards where inspection, servicing, isolation and breaker replacement are important. The exact product documentation also specifies a mechanical lockout device, tripped signalling switch, tripped indicators, 2-piece shutter with sealing cap and door sealing frame.
The ETU37WT LSING overcurrent release provides electronic protection for overload, short-circuit and earth-fault conditions, with a display and setting range according to the selected frame size. The exact product listing identifies the breaker as a 1000 A, 3-pole, 66 kA, manual draw-out ACB with ETU37WT protection.
The 1000 A rated current makes this ACB suitable for high-capacity electrical distribution applications including main incomers, industrial feeders, generator distribution systems and large low-voltage switchboards. The actual load current, busbar rating, prospective short-circuit current and protection coordination should always be evaluated before installation.
| Specification | Details |
|---|---|
| Product | Siemens 3WT8101-6AA04-5AB2 |
| Product Type | Withdrawable Air Circuit Breaker |
| Series | SENTRON 3WT8 |
| Configuration | 3-Pole |
| Frame Size | Size 1 |
| Rated Current (In) | 1000 A |
| Rated Operating Voltage | Up to 500 V AC |
| Frequency | 50/60 Hz |
| Ultimate Short-Circuit Breaking Capacity (Icu) | 66 kA at 500 V AC |
| Rated Short-Time Current Strength (Icw) | 66 kA/s |
| Overcurrent Release | ETU37WT LSING with display |
| Operating Mechanism | Manual operating mechanism with memory |
| Draw-Out Design | Manual Draw-Out (MDO) |
| Guide Frame | Included |
| Mechanical Lockout | Included |
| Tripped Signalling Switch | Included |
| Tripped Indicators | Included |
| Shutter | 2-piece shutter with sealing cap |
| Door Sealing Frame | Included |
| Standard | IEC 60947-2 |
The technical documentation for the exact MLFB identifies 3 poles, Size I, 1000 A, 500 V rated operational voltage and 66 kA short-circuit breaking capacity.
Siemens 3WT8101-6AA04-5AB2
SENTRON 3WT8 Air Circuit Breaker
1000 A rated current
3-pole (3P) configuration
Size 1
Manual draw-out withdrawable design
Guide frame
Rated operational voltage up to 500 V AC
50/60 Hz AC operation
66 kA Icu at 500 V AC
66 kA short-time current strength
ETU37WT LSING electronic overcurrent release
Integrated display
Overload protection
Short-circuit protection
Earth-fault protection
Mechanical lockout device
Tripped signalling switch
Tripped indicators
Manual operating mechanism with memory
2-piece shutter with sealing cap
Door sealing frame
The Siemens 3WT8101-6AA04-5AB2 1000A 3-pole withdrawable ACB can be considered for:
Main low-voltage switchboards
Main incomer applications
Industrial power distribution
High-current feeder protection
Generator distribution systems
Large manufacturing plants
Process industries
Commercial building main distribution
Infrastructure power systems
Industrial electrical switchboards
OEM switchgear assemblies
Critical power-distribution systems
High-capacity electrical panels
Power-distribution sections
Industrial and commercial electrical infrastructure
The 1000 A rated current makes the 3WT8101-6AA04-5AB2 suitable for high-capacity low-voltage distribution systems where substantial electrical loads require dependable switching and protection.
The 66 kA Icu at 500 V AC provides high short-circuit interruption capability for suitable high-fault-level installations. The exact product documentation confirms this rating for the 3WT8101-6AA04-5AB2.
The 3-pole construction provides coordinated protection and switching for compatible three-phase AC systems. This makes the breaker suitable for main distribution sections, high-current feeders and industrial three-phase power systems.
The manual draw-out design with guide frame provides operational flexibility for switchboard maintenance and inspection. The breaker can be withdrawn according to the manufacturer's prescribed procedure, supporting controlled isolation and servicing.
The ETU37WT LSING electronic overcurrent release with display provides electronic protection and monitoring for overload, short circuit and earth-fault conditions. This makes the ACB suitable for applications where adjustable electronic protection is required.
The mechanical lockout device supports controlled breaker operation during defined isolation and maintenance procedures. The tripped signalling switch and tripped indicators provide useful status information for operators and maintenance personnel.
The 2-piece shutter with sealing cap and door sealing frame support controlled access to the breaker compartment and organized switchgear integration.
The Siemens SENTRON 3WT8 series is intended for professional low-voltage power distribution, making the 3WT8101-6AA04-5AB2 suitable for OEMs, EPC contractors, panel builders, electrical contractors, system integrators and industrial maintenance teams.
For customers sourcing Siemens high-capacity ACBs across Faridabad, Delhi NCR, Noida, Gurgaon/Gurugram, Ghaziabad, Punjab, Mumbai, Pune, Ahmedabad, Hyderabad, Bengaluru/Bangalore, Chennai, Kolkata, Jaipur, Chandigarh, Ludhiana and other major industrial and commercial locations across India, this 1000 A withdrawable ACB can be considered for suitable switchgear applications.
Before installation or replacement, verify the complete MLFB, protection settings, guide-frame compatibility, busbar arrangement, prospective fault current, switchboard dimensions and coordination with upstream and downstream protection.
SB Smart supplies Siemens ACBs, circuit breakers, switchgear and industrial electrical products for OEMs, EPC contractors, panel builders, electrical contractors, system integrators and industrial maintenance teams across India.
The Siemens 3WT8101-6AA04-5AB2 1000A 3-pole withdrawable ACB is suitable for customers looking for high-capacity Siemens circuit protection for main distribution boards, industrial switchboards, high-current feeders, generator systems and infrastructure power-distribution applications.
SB Smart supports Siemens product sourcing across Faridabad, Delhi NCR, Noida, Gurgaon/Gurugram, Mumbai, Pune, Ahmedabad, Hyderabad, Bengaluru/Bangalore, Chennai, Kolkata, Chandigarh, Ludhiana and other major Indian industrial markets.
1. What is Siemens 3WT8101-6AA04-5AB2?
It is a Siemens SENTRON 3WT8 withdrawable Air Circuit Breaker with a 3-pole configuration, Size 1 and 1000 A rated current.
2. What is the rated current?
The rated current is 1000 A.
3. What is the short-circuit breaking capacity?
The specified Icu is 66 kA at 500 V AC.
4. What is the rated voltage?
The breaker is specified for applications up to 500 V AC at 50/60 Hz.
5. Is this circuit breaker withdrawable?
Yes. It is a manual draw-out withdrawable circuit breaker supplied with a guide frame.
6. What type of overcurrent release does it use?
It uses the ETU37WT LSING electronic overcurrent release with display, supporting overload, short-circuit and earth-fault protection.
7. What safety and indication features are included?
The configuration includes a mechanical lockout device, tripped signalling switch, tripped indicators, guide frame, 2-piece shutter with sealing cap and door sealing frame.
8. Where can this ACB be used?
It can be considered for suitable main switchboards, industrial power distribution, high-current feeders, generator systems, large electrical panels and infrastructure power-distribution applications.
|
Parameter |
Specification |
|
Product Series |
Siemens SENTRON
3WTPlus |
|
Part Number |
3WT8101-6AA04-5AB2 |
|
Product Type |
Air Circuit
Breaker Trip Unit |
|
Trip Unit Type |
Microprocessor
Based Electronic Trip Unit |
|
Poles |
3 Pole |
|
System Type |
Withdrawable /
Draw-out ACB |
|
Protection
Functions |
Overload, Short
Circuit, Earth Fault |
|
Monitoring |
Electronic
diagnostics & event logging |
|
Display |
LCD-compatible
monitoring |
|
Frequency |
50/60 Hz |
|
Standard |
IEC 60947-2 |
|
Application |
Industrial
& Infrastructure Power Distribution |